Kohler K-1210-AC, K-1215-AC, K-1205-AC, K-1206-AC, K-1220-AC manual ROUGHING-IN K-1200-AC, K-1201-AC

Page 5

1. ROUGHING-IN: K-1200-AC, K-1201-AC

A. ORDERING INFORMATION

Factory installed components include pump and air switch transmitter.

Information contained in this roughing-in also applies to K-1201-J1-AA, K-1201-J1-AB and K-1201-JA-AA.

Whirlpool with wall timer

 

K-1200-AC

 

 

 

Whirlpool with air actuator (shown)

K-1201-AC

 

 

 

Accessories/hardware:

 

 

 

 

 

Drain

K-7161-AF

recom-

 

 

mended

 

 

 

Vinyl tiling-in bead*

K-1177

optional

 

 

 

*Use K-1177 vinyl bead when wall material contacts any top surface of bath.

B. REQUIRED ELECTRICAL SERVICE

Dedicated circuits required, protected with Class A Ground-Fault Circuit-Interrupter (GFCI):

Pump/control

120 V., 15 A, 60 Hz

 

 

C. PRODUCT INFORMATION

Fixture:

basin area

top area

 

weight

 

 

 

 

 

 

 

Bathing well

42” x 17”

55” x 25”

 

93 lbs.

 

 

 

 

 

 

 

 

water depth

capacity

 

 

 

 

 

 

 

 

 

 

To overflow

12-1/8”

50 gals.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pump:

 

hp

V

Hz

 

A

 

 

 

 

 

 

 

60 Hz

 

1/2

120

60

 

8

 

 

 

 

 

 

 

D. INSTALLATION NOTES

Refer to installation instructions included with fixture before beginning installation.

ROUGHING-IN NOTES

Fixture dimensions are nominal and conform to toler- ances in ANSI Standard Z124.1.

No change in measurements if connected with drain illustrated.

 

Cut-out

28-1/2” x 58-1/2”

 

Minimum access:

 

FIELD WIRING COMPARTMENT

Pump/control box

20” W x 15” H panel required

15”

PUMP

 

 

 

1-1/2”

 

PUMP/CONTROL ACCESS

 

 

 

8-1/2”

30”

 

60”

2-3/4”

1-1/2”

 

 

 

17”

 

2-7/8”

3/16”

 

3”

1-1/2” I.P.S. THR’D

1.25>132

 

1-1/2” O.D.

Kohler Co., Kohler WI

5

106548-CA(9437)

Image 5
Contents 106548- CA Copyright E1994 Kohler Co Important Safety Instructions Table of Contents Introduction ROUGHING-IN K-1200-AC, K-1201-AC ROUGHING-IN K-1205-AC, K-1206-AC ROUGHING-IN K-1210-AC, K-1211-AC ROUGHING-IN K-1215-AC, K-1216-AC ROUGHING-IN K-1220-AC, K-1221-AC Product Notices Installer Hazard NotificationProduct Requirements NEW or Replacement Installation Requirements Installation RequirementsTools Required Materials Required Clearance RequirementsOLD Bath Removal Site RequirementsSubfloor Preparation Stud Pocket PreparationTILING-IN Bead Installation Before Installing UnitPartially Install Bath Drain Plumbing PreparationWhirlpool SET-IN Install WhirlpoolSecure Whirlpool Height AdjustmentInstall Plumbing Identify Electrical Requirements Wiring Information 120 V, 60 HZ Excluding -J1 ModelsElectrical Connections AIR Actuator Versions Field Wiring Diagram 120 V, 60 HZ -J1 Models only Locate Field Wiring Compartment 120 V, 60 HZ -J1 Models onlyConnect Control BOX 230 V, 50 HZ Field Wiring Control BOX Compartment 230 V, 50 HZWiring Information 120 V, 60 HZ Wall Timer Versions Electrical Connections Wall Timer VersionsComplete Finish Wall Water Test Whirlpool & ElectronicsOptional K-1507 Apron Installation Optional K-1515 Apron Installation Install Handles and Spout Complete InstallationCLEAN-UP After Installation Operating Sequence Confirm Proper OperationSTART-UP Whirlpool Troubleshoot Whirlpool System SymptomsProbable Causes Recommended ActionKohler Co., Kohler WI 106548-CA1093 106548-CA1093 Kohler Co., Kohler WI