Kohler K-1201-AC, K-1215-AC, K-1200-AC, K-1205-AC, K-1206-AC, K-1210-AC Important Safety Instructions

Page 2

IMPORTANT SAFETY INSTRUCTIONS

ATTENTION INSTALLER: INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC

SHOCK OR INJURY TO PERSONS

READ AND FOLLOW ALL INSTRUCTIONS

WARNING: When using this unit, always follow basic precautions, including the following:

DANGER: RISK OF ELECTRICAL SHOCK. The installation must have a Class A Ground-Fault Circuit-Interrupter (GFCI) for the whirlpool system.

This will provide additional protection against line-to-ground shock hazard.

Such a GFCI should be provided by the installer and should be tested on a routine basis.

To test the GFCI, press the test button. The GFCI should interrupt power. Press the reset button. Power should be restored.

If the GFCI fails to operate in this manner, there is a ground current flowing or the GFCI is defective. The possibility of an electric shock may exist. DO NOT use this unit. Disconnect the unit and have the problem corrected by a qualified licensed electrician.

For -J1 and -JA models only: A green colored terminal

(or a wire connector marked “G”, “GR”, “GROUND”, or “Grounding”) is provided within the terminal compartment. To reduce the risk of electric shock, connect this terminal or connector to the grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying this equipment.

All models: A pressure wire connector is provided on the exterior of the pump or control box within this unit to permit connection of a No. 8 AWG (8.4 mm2) solid copper bonding conductor between this unit and all other electrical equipment and exposed metal in the vicinity, as needed to comply with local requirements.

DO NOT operate this unit without the guard on the suction fitting.

Never drop or insert any object into any opening.

DANGER: To reduce the risk of injury, do not permit children to use this unit unless they are closely supervised at all times.

Use this unit only for its intended use as denoted in this manual. DO NOT use attachments not recommended by the Kohler Co.

SAVE THESE INSTRUCTIONS

106548-CA(9437)

2

Kohler Co., Kohler WI

Image 2
Contents 106548- CA Copyright E1994 Kohler Co Important Safety Instructions Table of Contents Introduction ROUGHING-IN K-1200-AC, K-1201-AC ROUGHING-IN K-1205-AC, K-1206-AC ROUGHING-IN K-1210-AC, K-1211-AC ROUGHING-IN K-1215-AC, K-1216-AC ROUGHING-IN K-1220-AC, K-1221-AC Installer Hazard Notification Product NoticesProduct Requirements Tools Required Materials Required Installation RequirementsNEW or Replacement Installation Requirements Clearance RequirementsSubfloor Preparation Site RequirementsOLD Bath Removal Stud Pocket PreparationPartially Install Bath Drain Before Installing UnitTILING-IN Bead Installation Plumbing PreparationInstall Whirlpool Whirlpool SET-INSecure Whirlpool Height AdjustmentInstall Plumbing Identify Electrical Requirements Wiring Information 120 V, 60 HZ Excluding -J1 ModelsElectrical Connections AIR Actuator Versions Locate Field Wiring Compartment 120 V, 60 HZ -J1 Models only Field Wiring Diagram 120 V, 60 HZ -J1 Models onlyField Wiring Control BOX Compartment 230 V, 50 HZ Connect Control BOX 230 V, 50 HZElectrical Connections Wall Timer Versions Wiring Information 120 V, 60 HZ Wall Timer VersionsWater Test Whirlpool & Electronics Complete Finish WallOptional K-1507 Apron Installation Optional K-1515 Apron Installation Install Handles and Spout Complete InstallationCLEAN-UP After Installation Operating Sequence Confirm Proper OperationSTART-UP Whirlpool Probable Causes SymptomsTroubleshoot Whirlpool System Recommended ActionKohler Co., Kohler WI 106548-CA1093 106548-CA1093 Kohler Co., Kohler WI