Kohler K-1215-AC, K-1200-AC, K-1201-AC, K-1205-AC, K-1206-AC ROUGHING-IN K-1210-AC, K-1211-AC

Page 7

3. ROUGHING-IN: K-1210-AC, K-1211-AC

A. ORDERING INFORMATION

Factory installed components include pump and air switch transmitter.

Information contained in this roughing-in also applies to K-1211-J1-AA, K-1211-J1-AB and K-1211-JA-AA.

Whirlpool with wall timer

 

K-1210-AC

 

 

 

Whirlpool with air actuator (shown)

K-1211-AC

 

 

 

Accessories/hardware:

 

 

 

 

 

Drain

K-7161-AF

recom-

 

 

mended

 

 

 

Vinyl tiling-in bead*

K-1179

optional

 

 

 

*Use K-1179 vinyl bead when wall material contacts any top surface of bath.

B. REQUIRED ELECTRICAL SERVICE

Dedicated circuits required, protected with Class A Ground-Fault Circuit-Interrupter (GFCI):

Pump/control

120 V., 15 A, 60 Hz

 

 

C. PRODUCT INFORMATION

Fixture:

basin area

top area

 

weight

 

 

 

 

 

 

 

Bathing well

39” x 22”

54” x 27”

 

85 lbs.

 

 

 

 

 

 

 

 

water depth

capacity

 

 

 

 

 

 

 

 

 

 

To overflow

15-1/2”

65 gals.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pump:

 

hp

V

Hz

 

A

 

 

 

 

 

 

 

60 Hz

 

1/2

120

60

 

8

 

 

 

 

 

 

 

D. INSTALLATION NOTES

Refer to installation instructions included with fixture before beginning installation.

*Some K-1179 tiling-in beads may require trimming of the bottom edge for proper fit.

FIELD WIRING COMPARTMENT

18”

1-7/8”

8-7/8”

59-9/16”

3-1/4”

2-7/8” 1-1/8” 3”

1.25>132

ROUGHING-IN NOTES

Fixture dimensions are nominal and conform to toler- ances in ANSI Standard Z124.1.

No change in measurements if connected with drain illustrated.

Cut-out

34-1/2” x 58-1/2”

 

 

Minimum access:

 

 

 

Pump/control box

20” W x 15” H panel required

PUMP

PUMP/CONTROL ACCESS

 

 

 

 

 

 

 

 

1-3/4”

 

 

36”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21”

1-1/2” I.P.S. THR’D

1-1/2” O.D.

Kohler Co., Kohler WI

7

106548-CA(9437)

Image 7
Contents 106548- CA Copyright E1994 Kohler Co Important Safety Instructions Table of Contents Introduction ROUGHING-IN K-1200-AC, K-1201-AC ROUGHING-IN K-1205-AC, K-1206-AC ROUGHING-IN K-1210-AC, K-1211-AC ROUGHING-IN K-1215-AC, K-1216-AC ROUGHING-IN K-1220-AC, K-1221-AC Product Notices Installer Hazard NotificationProduct Requirements Clearance Requirements Installation RequirementsNEW or Replacement Installation Requirements Tools Required Materials RequiredStud Pocket Preparation Site RequirementsOLD Bath Removal Subfloor PreparationPlumbing Preparation Before Installing UnitTILING-IN Bead Installation Partially Install Bath DrainWhirlpool SET-IN Install WhirlpoolInstall Plumbing Height AdjustmentSecure Whirlpool Electrical Connections AIR Actuator Versions Wiring Information 120 V, 60 HZ Excluding -J1 ModelsIdentify Electrical Requirements Field Wiring Diagram 120 V, 60 HZ -J1 Models only Locate Field Wiring Compartment 120 V, 60 HZ -J1 Models onlyConnect Control BOX 230 V, 50 HZ Field Wiring Control BOX Compartment 230 V, 50 HZWiring Information 120 V, 60 HZ Wall Timer Versions Electrical Connections Wall Timer VersionsComplete Finish Wall Water Test Whirlpool & ElectronicsOptional K-1507 Apron Installation Optional K-1515 Apron Installation CLEAN-UP After Installation Complete InstallationInstall Handles and Spout START-UP Whirlpool Confirm Proper OperationOperating Sequence Recommended Action SymptomsTroubleshoot Whirlpool System Probable CausesKohler Co., Kohler WI 106548-CA1093 106548-CA1093 Kohler Co., Kohler WI