Kohler K-1210-AC, K-1215-AC, K-1200-AC, K-1201-AC, K-1205-AC Install Whirlpool, Whirlpool SET-IN

Page 15

11. INSTALL WHIRLPOOL

A. WHIRLPOOL SET-IN

Choose one of the three recommended options below that is best for your particular installation as described in 1., 2., or 3. Follow the appropriate instructions.

If subfloor is not level, some shimming of the bath and pump will be necessary. See 11.B. for height adjustment.

1.Sunken Installation: Set unit into sunken installation. Make sure the bath/whirlpool is level and is resting on all blocks. Insert the tailpiece into the trap. Apply a bead of RTV sealant under rim of the bath unit.

2.Install Using Gypsum: Place a 2” thick layer of gypsum cement (such as Gyp-Crete 2000) on the floor where the whirlpool is to be set. This will help secure, level and support the bath. Set bath into position. Clear any excess cement from vicinity of the pump.

NOTE: Pump bracket must sit flat on the floor.

Insert tailpiece into trap. Make sure bath is level and resting on all supporting blocks.

3.Install Using 1 x 2 Strips: Set whirlpool in desired location and level. Nail 1 x 2 wood strips around blocks under the whirlpool to firmly hold it in position. It is not necessary to use strips on all blocks. They are only needed on blocks that are to the outside edges of your installation.

Insert tailpiece into trap. Make sure bath is level and resting on all supporting blocks.

Whirlpool

Blocks

Wood

Strips

Wood

Strips

Kohler Co., Kohler WI

15

106548-CA(9437)

Image 15
Contents 106548- CA Copyright E1994 Kohler Co Important Safety Instructions Table of Contents Introduction ROUGHING-IN K-1200-AC, K-1201-AC ROUGHING-IN K-1205-AC, K-1206-AC ROUGHING-IN K-1210-AC, K-1211-AC ROUGHING-IN K-1215-AC, K-1216-AC ROUGHING-IN K-1220-AC, K-1221-AC Product Notices Installer Hazard NotificationProduct Requirements Clearance Requirements Installation RequirementsNEW or Replacement Installation Requirements Tools Required Materials RequiredStud Pocket Preparation Site RequirementsOLD Bath Removal Subfloor PreparationPlumbing Preparation Before Installing UnitTILING-IN Bead Installation Partially Install Bath DrainWhirlpool SET-IN Install WhirlpoolHeight Adjustment Install PlumbingSecure Whirlpool Wiring Information 120 V, 60 HZ Excluding -J1 Models Electrical Connections AIR Actuator VersionsIdentify Electrical Requirements Field Wiring Diagram 120 V, 60 HZ -J1 Models only Locate Field Wiring Compartment 120 V, 60 HZ -J1 Models onlyConnect Control BOX 230 V, 50 HZ Field Wiring Control BOX Compartment 230 V, 50 HZWiring Information 120 V, 60 HZ Wall Timer Versions Electrical Connections Wall Timer VersionsComplete Finish Wall Water Test Whirlpool & ElectronicsOptional K-1507 Apron Installation Optional K-1515 Apron Installation Complete Installation CLEAN-UP After InstallationInstall Handles and Spout Confirm Proper Operation START-UP WhirlpoolOperating Sequence Recommended Action SymptomsTroubleshoot Whirlpool System Probable CausesKohler Co., Kohler WI 106548-CA1093 106548-CA1093 Kohler Co., Kohler WI