Eaton Electrical SC200 manual About This Guide

Page 3

.

About This Guide

Purpose

This guide provides instructions to correctly install, commission and operate Data Power Solutions.

Audience

This guide is intended for use by IT professionals who have a sound working knowledge of safe working practices.

Scope

This guide covers installation, commissioning and operation of Data Power Solutions, controlled by SM45 supervisory modules.

It does not cover:

Installation and characterization of batteries.

Changing the pre-configured configuration values. For full details on changing the pre- configured configuration values, refer to the SM45 Front Panel Menu Structure (on the inside back cover) or DCTools online help.

Related Information

DCTools Online Help

Application Note AN0080: Ventilation of VRLA Batteries

Reporting Problems with This Guide

Please use the fax or email addresses below to report any problems you find in this guide. Powerware DC Marketing Services

FAX:

++64 3 343 5660

EMAIL: DCMarketingNZ@eaton.com

Copyright © 2005-2006 Eaton Corporation. All Rights Reserved.

IPN 997-00012-41D December 2006

i

Image 3
Contents Data Power Solutions Installation Guide Copyright 2005-2006 Eaton Corporation All Rights Reserved About This Guide About This Guide For Further Information and Technical AssistanceTable of Contents Chapter Operations Table of ContentsGeneral Description OverviewTopic General Description Data Power Solutions Product RangeAPS3-05X Rack-Mounted Versions Data Power Solutions Product RangeAPS3-06X Desktop Versions APS6-05X Rack-Mounted Versions Access Power Rectifiers SM45 Supervisory Module SM45 Supervisory ModuleLow Voltage Disconnect if applicable Pre-Installation AC Inputs Pre-InstallationBatteries if applicable DC Outputs Servicing Inspecting the Equipment and Reporting Damage Installation Location and Environment Mounting the Power SystemInstallation Rack Installation rack-mounted versions onlyDC Installation Practices Connecting the DC Load CablesDC Installation Practices APS3-05X and APS6-05X Rack-Mounted Versions Installation DC Load Cable SpecificationsFit load cable clamps Connecting the DC Load CablesFit cables and sleeves Battery Location Installing the External Batteries if applicableInstalling the External Batteries if applicable Battery SizingBefore You Start Connecting the Battery Cables if applicableBattery Fault Protection Battery Cable SpecificationsPrepare cable clamp Connecting the Battery Cables if applicableConnecting the Battery Temperature Sensor Cable Repeat for other battery cables if requiredMounting the Battery Temperature Sensor Connecting the Power System to the AC Supply AC InstallationAC Supply Requirements Commissioning Commissioning Inserting the Access Power RectifiersPre-Power-Up Check Pre-Power-Up CheckChecklist Configuring the Power System for Operation Applying AC PowerBefore you start, you need Configuring the Power System for OperationLVD Hotlink Click to …Page Applying DC Power to the Load SM45 Operations SM45 Operations About the SM45 Front PanelTo disable the audible indicator when an alarm is active About the SM45 Front PanelTo change the display contrast About Display Modes To enter a display modeTo exit a display mode To scroll within a display modeViewing System Values Main Display Mode Viewing System Values Main Display ModeTo view system values To view and clear alarms Viewing Alarms and System Status Messages Status View ModeRules for displaying alarms and system status Important note about Rect Comms Lost alarmViewing and Editing Configuration Parameters Viewing and Editing Configuration ParametersTo view and edit a configuration parameter SM45 Operations Communications Communications Options CommunicationsDirect Connection Ethernet Properties Direct Connection Ethernet DCTools SetupSM45 Ethernet Setup DCTools SetupParameter Configuration Guidelines Setting Up Snmp TrapsEntering the sysObjectID of a Power System Entering the sysObjectID of a Power SystemTo enter the sysObjectID of a power system using DCTools Synchronizing the SM45 Real-time Clock To synchronize the SM45 real-time clock using DCToolsMaintenance Troubleshooting MaintenanceProblem Possible Cause/s Required Action Troubleshooting LED Config Error Removing a Rectifier Replacing a RectifierReplacing a Rectifier Pull out the rectifierInserting a Rectifier Replacing AC Input Fuses Replacing AC Input FusesTo check and replace AC input fuses Replacing the SM45 Real-time Clock Battery Glossary of Alarms Rectifier Fail Sensor Fail System Overload Glossary of AlarmsMultiple Rectifier Fail Partial AC Fail Rectifier Comms LostControl Function Glossary Battery Current Limit BCLControl Function Glossary Low Volts DisconnectEnvironment SpecificationsSystem AC Input System DC OutputAPR48 Rectifiers SpecificationsDimensions H, W, D WeightEquipment Incident Report SG/03 ISS04 United States of America Worldwide SupportPage Page Page SM45 Front Panel Menu Structure Configuration Mode Edit Mode