Eaton Electrical SC200 manual Communications Options, Direct Connection Ethernet

Page 50

Communications

Communications Options

The SM45 supervisory module communicates to a designated PC (running the DCTools software) via a:

Standard RS-232 serial interface, or

Ethernet 10BaseT interface, both accessible from the front panel Shown below are the two standard communications options.

Direct Connection

Ethernet

6-2

Copyright © 2005-2006 Eaton Corporation. All Rights Reserved.

IPN 997-00012-41D December 2006

 

Image 50
Contents Data Power Solutions Installation Guide Copyright 2005-2006 Eaton Corporation All Rights Reserved About This Guide For Further Information and Technical Assistance About This GuideTable of Contents Table of Contents Chapter OperationsTopic General DescriptionOverview Data Power Solutions Product Range General DescriptionData Power Solutions Product Range APS3-05X Rack-Mounted VersionsAPS3-06X Desktop Versions APS6-05X Rack-Mounted Versions Access Power Rectifiers SM45 Supervisory Module SM45 Supervisory ModuleLow Voltage Disconnect if applicable Pre-Installation Pre-Installation AC InputsBatteries if applicable DC Outputs Servicing Inspecting the Equipment and Reporting Damage Installation Rack Installation rack-mounted versions only Mounting the Power SystemInstallation Location and EnvironmentDC Installation Practices DC Installation PracticesConnecting the DC Load Cables Installation DC Load Cable Specifications APS3-05X and APS6-05X Rack-Mounted VersionsConnecting the DC Load Cables Fit load cable clampsFit cables and sleeves Battery Sizing Installing the External Batteries if applicableInstalling the External Batteries if applicable Battery LocationBattery Cable Specifications Connecting the Battery Cables if applicableBattery Fault Protection Before You StartConnecting the Battery Cables if applicable Prepare cable clampRepeat for other battery cables if required Connecting the Battery Temperature Sensor CableMounting the Battery Temperature Sensor AC Supply Requirements Connecting the Power System to the AC SupplyAC Installation Commissioning Inserting the Access Power Rectifiers CommissioningChecklist Pre-Power-Up CheckPre-Power-Up Check Applying AC Power Configuring the Power System for OperationConfiguring the Power System for Operation Before you start, you needHotlink Click to … LVDPage Applying DC Power to the Load SM45 Operations About the SM45 Front Panel SM45 OperationsTo change the display contrast To disable the audible indicator when an alarm is activeAbout the SM45 Front Panel To scroll within a display mode To enter a display modeTo exit a display mode About Display ModesTo view system values Viewing System Values Main Display ModeViewing System Values Main Display Mode Important note about Rect Comms Lost alarm Viewing Alarms and System Status Messages Status View ModeRules for displaying alarms and system status To view and clear alarmsTo view and edit a configuration parameter Viewing and Editing Configuration ParametersViewing and Editing Configuration Parameters SM45 Operations Communications Direct Connection Ethernet Communications OptionsCommunications DCTools Setup DCTools SetupSM45 Ethernet Setup Properties Direct Connection EthernetSetting Up Snmp Traps Parameter Configuration GuidelinesTo enter the sysObjectID of a power system using DCTools Entering the sysObjectID of a Power SystemEntering the sysObjectID of a Power System To synchronize the SM45 real-time clock using DCTools Synchronizing the SM45 Real-time ClockMaintenance Problem Possible Cause/s Required Action TroubleshootingMaintenance Troubleshooting LED Config Error Replacing a Rectifier Removing a RectifierPull out the rectifier Replacing a RectifierInserting a Rectifier To check and replace AC input fuses Replacing AC Input FusesReplacing AC Input Fuses Replacing the SM45 Real-time Clock Battery Glossary of Alarms Partial AC Fail Rectifier Comms Lost Glossary of AlarmsMultiple Rectifier Fail Rectifier Fail Sensor Fail System OverloadBattery Current Limit BCL Control Function GlossaryLow Volts Disconnect Control Function GlossarySystem DC Output SpecificationsSystem AC Input EnvironmentWeight SpecificationsDimensions H, W, D APR48 RectifiersEquipment Incident Report SG/03 ISS04 Worldwide Support United States of AmericaPage Page Page SM45 Front Panel Menu Structure Configuration Mode Edit Mode