Site Preparation
•Space for the shelves, which are designed for 19” rack or wall mounting.
•Each shelf measures 15” high x 19” wide x 9” deep, and weighs approximately 35 pounds fully loaded.
•Expansion shelves cannot be located more than 17 cable feet from the Primary Shelf.
•All digital interface modules must be within 250 feet of the telephone system.
•See your telephone system specifications for distance limitations for analog modules.
•Location of the Intershelf Junction Panel (JPI300) adjacent to the shelves on a
•The Primary Shelf containing the System Controller (CSC or CSO306 or 320) must be mounted to allow connection to the JPI300 with a
•Expansion Shelves (CSC300 or CSO300) must be mounted to allow connection of the shelf to the JPI300 using 12 feet or less of cabling.
•Space for the
•Maximum loop length specifications of the telephone system
•Maximum wire distance from the MCU to a Base Station (6,000 feet)
•Cabling for the Interface Modules and Controller cards. All cables (except power) are connected to the front face of the cards. Space is provided to route wiring to the back of the shelf.
Prepare rack or wall
The SpectraLink 6300 MCU can be mounted in a rack or on the wall. Rack or wall support must be adequate to support the number of shelves to be installed. Each fully loaded SpectraLink 6300 MCU shelf weighs approximately 35 pounds.
Rack mounting
Before installing shelves in a rack, be sure the rack is mechanically fastened to the floor or wall such that it properly supports the number
PN: | 23 |