Wallboard Installation and MaintenanceWallboard 22
Baud Rate
Dip Switch Settings are:
SW5 | SW6 | DATA BIT/SEC |
OFF | OFF | 19200 |
|
|
|
ON | OFF | 9600 |
|
|
|
OFF | ON | 2400 |
ON | ON | 1200 |
|
|
|
Ensure the Baud rate is set to 9600.
Test Functions
SW7 | SW8 | FUNCTION |
OFF | OFF | Normal Running |
ON | OFF | Diagonal Stripe Test |
OFF | ON | Full Screen LED Test |
ON | ON | Information Screen |
|
| (Only on power up) |
|
|
|
The information screen shows three pages where the following text is displayed. The dip switches must be set with the display powered down, then switch power on to achieve information screen.
Yellow Text | Software Version |
| Sign Type |
|
|
Green Text | Network |
| Number |
Red Text | Baud |
| Rate |
|
|
|
|
Compact Contact Center | Installation & Maintenance |
40DHB0002USBG Issue 1 (11/14/2001) | Wallboard Installation and Maintenance • Page 38 |