Orion LBI-38888K Priority System Scan, When Wide Area System Scan Is Enabled, Menu Selection

Page 38

Priority System Scan

The radio may also be programmed for Priority System Scan. (To ensure that this feature operates correctly, the control channel of the priority system must be located on channel one unless you are using the ProSound / ProScan algorithm). The priority system is the desired or preferred system. While receiving the control channel of the selected system, the radio will periodically leave the selected system and search for the control channel of the priority system at a programmable rate. The programmable rate is defined by the value in the Priority Scan Time control, (unless the ProSound

/ProScan algorithm is enabled as explained below). This priority scan timer is reset each time the PTT button is pressed or when a call is received. If the priority system control channel is found, or meets the predefined ProSound/ProScan criteria, the radio will automatically switch to the priority system.

When Wide Area System Scan Is Enabled

If the radio cannot find the control channel of the selected system and begins to wide area system scan, the radio will only scan for the priority system control channel if the priority system is in the Wide Area System Scan list.

When ProSound/ProScan Is Enabled

The radio monitors the priority system and will switch to the priority system if the system meets the criteria defined in the ProSound / ProScan Options Dialog Box. If ProSound / ProScan is enabled the rate at which the radio will scan for the priority system is defined by the System Sample Time control.

Menu Selection

Press M and then use the , . control to scroll through the

selections until SYS SCAN is displayed. Then press M to toggle the System Scan state. The SYSC ON or SYSC OFF display message is displayed for two seconds to show the new state.

Pre-Programmed Keypad Key

Press the pre-programmed key and the SYSC ON or SYSC OFF display message is displayed for two seconds to show the new state.

38

Image 38
Contents Orion Product Specification for CE Marked Equipment Table of Contents Table of Contents Interference To Vehicular Electronic Systems Safety InformationList of the possible hazards are Explosive Atmospheres Dynamite Blasting CapsIntroduction User InterfaceOrion Mobile Radio System Model Front Panel SYSTEM/GROUP Channel Knob Power ON-OFF Volume KnobControls Scan ON/OFF IndicatorsRamp Control Scan ADD/DELETEKeypad Orion System Model KeypadKey Descriptions Standard Keycap ConfigurationOptional Keycap Configuration Entry see Selection Mode Rules Primary Functions Quick Access ALMDisplay Radio Status IconsMessages Message Name DescriptionTX Data WHC=1 FIX List Spkr on System Busy Trunked Mode only Autokey Trunked Mode onlyCall Queued Trunked Mode only Alert TonesDual Control Switching Call Denied Trunked Mode onlyCarrier Control Timer OperationSelection Mode Rules Turning on the RadioDirect Access U T HMenu N U K L G H T Press SEL Menu Item Information Feature Display Parameter Comment Settings SYS Scan Serial Number ROM 12 Hex Digits Example Feature Encryption DisplayFeature Encryption Data Stream Features Enabled Number FieldsBIT Fields Possible Features SYSTEM/GROUP/CHANNEL Selection System SelectionGroup And Channel Selection Sending a Call Trunked Mode OperationReceiving a Call Receiving An Emergency Call Conventional FailsoftEmergency Operation Wide Area System Scan System Scan OperationDeclaring An Emergency Call ProSoundTM ProScanTMPriority System Scan When Wide Area System Scan Is EnabledWhen ProSound/ProScan Is Enabled Menu SelectionGroup Scan Operation Adding Groups To a Scan List Deleting Groups From a Scan ListPriority Group Scanning Nuisance DeleteTurning Scan on Receiving and Responding To An Individual Call Individual CallsTurning Scan OFF Page Scat Operation Sending An Individual CallTelephone Interconnect Calls Receiving a Telephone Interconnect Call Trunked Mode OnlySending a Telephone Interconnect Call Trunked Mode Only Dtmf Overdial/Conventional Mode Telephone Interconnect Programmable Entries Mobile Data DisplaysData OFF Operation Data On OperationScan Lockout Mode Exiting Data CallsData Lockout Mode STATUS/MESSAGE OperationStatus Operation Edacs Conventional P1 Scan Message OperationEmergency Operation Conventional Mode OperationDynamic Regroup Operation Receiving a Call Using 5-Tone Signalling for Emergency Declaration Tone Encode TransmissionScanning Conventional Channels Adding Channels To a Scan List Deleting Channels From a Scan ListTurning Scan on Turning Scan OFFSquelch Adjust Noise Blanker Operation Type 99 Decode Conventional OnlyMenu Selection Direct Mode Operation Conventional System Only Voice Modes Trunked or Conventional Mode OperationSIREN/LIGHT Operation Clear Modes AEGIS/ProVoice Digital ModeYes Error Messages ERR=xxxxPage Transferring Keys Into The Radio Displaying The Currently Used Cryptographic Key NumberTransmitting An Encrypted Call Key ZeroPrivate Operation Receiving An Encrypted Call Scanned Group Calls Conventional Operation Outside AddressDual Control Operation Switching ControlControl Switching Modes Channel GuardSiren And Light Control Slaved Mode OperationIndependent Mode Operation Changing Selected Radio Multiple Radio OperationDual Control Audio Shared Control Unit Display ModesAudio Summed First Come First Serve DisplayAudio Modes Audio First Come First ServeMacro KEY Operation Page Keypad Remapping Operating Rules and Regulations Glossary Controller Group Or Subfleet Group Scan Individual Call QueueingSite SystemInter Talk-aroundTelephone ConnectOperators Radio Setup Radio Type Frequency Band Operators Name Emergency GroupWarranty Emergency Numbers Operating Tips