Orion LBI-38888K manual Menu Selection

Page 62

Type 99 operation may be reset manually or automatically (pre-

programmed). Manual reset is achieved by briefly pressing c, if programmed. Automatic reset, if enabled, occurs after a 30 second interval following the most recent decode of a Type 99 tone sequence. Hookswitch (pre-programmed) may also enable or disable Type 99 decode. The pre- programmed key light will blink when Type 99 is disabled by the hookswitch.

Type 99 decode will continue to be active while the radio's cbutton is pressed. This allows the user to monitor calls and still be alerted when a call

is directed to the user. While the user continues to press c, the user will

hear both calls and all Type 99 tone signals. If c is pressed for longer than two (2) seconds, Type 99 decode will either be disabled or re-enabled depending upon its present state.

To check the Type 99 enable status, press the Scan Add/Delete <or >. The current status of Type 99 decode will be displayed for a time-out period. Type 99 is enabled when the letter T is displayed in the third segment from right on the first line of the LCD display.

If a Horn Alert Option is installed and enabled with the Type 99 Decode Option, the radio can beep the vehicle horn whan a Type 99 call is received. This option permits alerting persons out of the vehicle when a call is received.

NOTE

Type 99 is automatically disabled when Scan is enabled.

Menu Selection

Press Mand then use .,control to scroll through the selections

until T99 ENAB is displayed. Then press M to toggle the Type 99 decode state. The T99 ON or T99 OFF display message is displayed for two seconds to show the new state.

Pre-Programmed Keypad Key

Press the pre-programmed key and the T99 ON or T99 OFF display message is displayed for two seconds to show the new state.

62

Image 62
Contents Orion Product Specification for CE Marked Equipment Table of Contents Table of Contents Interference To Vehicular Electronic Systems Safety InformationList of the possible hazards are Explosive Atmospheres Dynamite Blasting CapsIntroduction User InterfaceOrion Mobile Radio System Model Front Panel SYSTEM/GROUP Channel Knob Power ON-OFF Volume KnobControls Scan ON/OFF IndicatorsRamp Control Scan ADD/DELETEKeypad Orion System Model KeypadKey Descriptions Standard Keycap ConfigurationOptional Keycap Configuration Entry see Selection Mode Rules Primary Functions Quick Access ALMDisplay Radio Status IconsMessages Message Name DescriptionTX Data WHC=1 FIX List Spkr on System Busy Trunked Mode only Autokey Trunked Mode onlyCall Queued Trunked Mode only Alert TonesDual Control Switching Call Denied Trunked Mode onlyCarrier Control Timer OperationSelection Mode Rules Turning on the RadioDirect Access U T HMenu N U K L G H T Press SEL Menu Item Information Feature Display Parameter Comment Settings SYS Scan Serial Number ROM 12 Hex Digits Example Feature Encryption DisplayFeature Encryption Data Stream Features Enabled Number FieldsBIT Fields Possible Features SYSTEM/GROUP/CHANNEL Selection System SelectionGroup And Channel Selection Sending a Call Trunked Mode OperationReceiving a Call Receiving An Emergency Call Conventional FailsoftEmergency Operation Wide Area System Scan System Scan OperationDeclaring An Emergency Call ProSoundTM ProScanTMPriority System Scan When Wide Area System Scan Is EnabledWhen ProSound/ProScan Is Enabled Menu SelectionGroup Scan Operation Adding Groups To a Scan List Deleting Groups From a Scan ListPriority Group Scanning Nuisance DeleteTurning Scan on Receiving and Responding To An Individual Call Individual CallsTurning Scan OFF Page Scat Operation Sending An Individual CallTelephone Interconnect Calls Receiving a Telephone Interconnect Call Trunked Mode OnlySending a Telephone Interconnect Call Trunked Mode Only Dtmf Overdial/Conventional Mode Telephone Interconnect Programmable Entries Mobile Data DisplaysData OFF Operation Data On OperationScan Lockout Mode Exiting Data CallsData Lockout Mode STATUS/MESSAGE OperationStatus Operation Edacs Conventional P1 Scan Message OperationEmergency Operation Conventional Mode OperationDynamic Regroup Operation Receiving a Call Using 5-Tone Signalling for Emergency Declaration Tone Encode TransmissionScanning Conventional Channels Adding Channels To a Scan List Deleting Channels From a Scan ListTurning Scan on Turning Scan OFFSquelch Adjust Noise Blanker Operation Type 99 Decode Conventional OnlyMenu Selection Direct Mode Operation Conventional System Only Voice Modes Trunked or Conventional Mode OperationSIREN/LIGHT Operation Clear Modes AEGIS/ProVoice Digital ModeYes Error Messages ERR=xxxxPage Transferring Keys Into The Radio Displaying The Currently Used Cryptographic Key NumberTransmitting An Encrypted Call Key ZeroPrivate Operation Receiving An Encrypted Call Scanned Group Calls Conventional Operation Outside AddressDual Control Operation Switching ControlControl Switching Modes Channel GuardSiren And Light Control Slaved Mode OperationIndependent Mode Operation Changing Selected Radio Multiple Radio OperationDual Control Audio Shared Control Unit Display ModesAudio Summed First Come First Serve DisplayAudio Modes Audio First Come First ServeMacro KEY Operation Page Keypad Remapping Operating Rules and Regulations Glossary Controller Group Or Subfleet Group Scan Individual Call QueueingSite SystemInter Talk-aroundTelephone ConnectOperators Radio Setup Radio Type Frequency Band Operators Name Emergency GroupWarranty Emergency Numbers Operating Tips