Orion LBI-38888K manual Controls, Power ON-OFF Volume Knob, SYSTEM/GROUP Channel Knob

Page 8

CONTROLS

This section describes the buttons, keys and rotary knobs used to control the Orion Scan and System Model radios. All functions and controls of the Scan radio operate the same as the corresponding functions and controls on the System radio. The Scan radio is equipped with a 4-button keypad and the System radio is equipped with a 16-button keypad.

Many of the control buttons and keys have or can be programmed to have a primary function and a secondary function. The SCAN button can be programmed (as a secondary function) to toggle the keypad keys between their primary function and their secondary function.

POWER ON-OFF VOLUME KNOB

This rotary Knob applies power to the radio and adjusts the receiver volume. Rotating the control clockwise out of detente applies power to the radio. A single alert tone sounds (if enabled through programming) to indicate the radio is operational.

Rotating the control clockwise increases the volume level. Minimum volume levels may be programmed into the radio to prevent missed calls due to a low volume setting. While adjusting the volume, the display will momentarily indicate the volume level (i.e. VOL = 31). The volume range is from a minimum level of zero (displayed as OFF in the display) up to 31 which is the loudest level.

SYSTEM/GROUP CHANNEL KNOB

This rotary knob selects the systems or groups/channels, depending upon programming. This 16 position knob has

no stop. See SYSTEM/GROUP/CHANNEL SELECTION for more details.

8

Image 8
Contents Orion Product Specification for CE Marked Equipment Table of Contents Table of Contents Safety Information List of the possible hazards are Explosive AtmospheresInterference To Vehicular Electronic Systems Dynamite Blasting CapsIntroduction User InterfaceOrion Mobile Radio System Model Front Panel SYSTEM/GROUP Channel Knob Power ON-OFF Volume KnobControls Indicators Ramp ControlScan ON/OFF Scan ADD/DELETEKeypad Orion System Model KeypadKey Descriptions Standard Keycap ConfigurationOptional Keycap Configuration Entry see Selection Mode Rules Primary Functions Quick Access ALMDisplay Radio Status IconsMessages Message Name DescriptionTX Data WHC=1 FIX List Spkr on Autokey Trunked Mode only Call Queued Trunked Mode onlySystem Busy Trunked Mode only Alert TonesCall Denied Trunked Mode only Carrier Control TimerDual Control Switching OperationSelection Mode Rules Turning on the RadioDirect Access U T HMenu N U K L G H T Press SEL Menu Item Information Feature Display Parameter Comment Settings SYS Scan Serial Number ROM 12 Hex Digits Example Feature Encryption DisplayFeature Encryption Data Stream Features Enabled Number FieldsBIT Fields Possible Features SYSTEM/GROUP/CHANNEL Selection System SelectionGroup And Channel Selection Sending a Call Trunked Mode OperationReceiving a Call Receiving An Emergency Call Conventional FailsoftEmergency Operation Wide Area System Scan System Scan OperationDeclaring An Emergency Call ProSoundTM ProScanTMWhen Wide Area System Scan Is Enabled When ProSound/ProScan Is EnabledPriority System Scan Menu SelectionGroup Scan Operation Adding Groups To a Scan List Deleting Groups From a Scan ListPriority Group Scanning Nuisance DeleteTurning Scan on Receiving and Responding To An Individual Call Individual CallsTurning Scan OFF Page Scat Operation Sending An Individual CallTelephone Interconnect Calls Receiving a Telephone Interconnect Call Trunked Mode OnlySending a Telephone Interconnect Call Trunked Mode Only Dtmf Overdial/Conventional Mode Telephone Interconnect Programmable Entries Mobile Data DisplaysData OFF Operation Data On OperationScan Lockout Mode Exiting Data CallsData Lockout Mode STATUS/MESSAGE OperationStatus Operation Edacs Conventional P1 Scan Message OperationEmergency Operation Conventional Mode OperationDynamic Regroup Operation Receiving a Call Using 5-Tone Signalling for Emergency Declaration Tone Encode TransmissionScanning Conventional Channels Adding Channels To a Scan List Deleting Channels From a Scan ListTurning Scan on Turning Scan OFFSquelch Adjust Noise Blanker Operation Type 99 Decode Conventional OnlyMenu Selection Direct Mode Operation Conventional System Only Voice Modes Trunked or Conventional Mode OperationSIREN/LIGHT Operation Clear Modes AEGIS/ProVoice Digital ModeYes Error Messages ERR=xxxxPage Transferring Keys Into The Radio Displaying The Currently Used Cryptographic Key NumberTransmitting An Encrypted Call Key ZeroPrivate Operation Receiving An Encrypted Call Scanned Group Calls Conventional Operation Outside AddressSwitching Control Control Switching ModesDual Control Operation Channel GuardSiren And Light Control Slaved Mode OperationIndependent Mode Operation Multiple Radio Operation Dual Control AudioChanging Selected Radio Shared Control Unit Display ModesFirst Come First Serve Display Audio ModesAudio Summed Audio First Come First ServeMacro KEY Operation Page Keypad Remapping Operating Rules and Regulations Glossary Group Or Subfleet Group Scan Individual Call Queueing SiteController SystemTalk-around TelephoneInter ConnectOperators Radio Setup Radio Type Frequency Band Operators Name Emergency GroupWarranty Emergency Numbers Operating Tips