Orion LBI-38888K manual Edacs Conventional P1 Scan, Message Operation

Page 53

Message Operation

Message operation permits the transmission of a pre-programmed message text to an EDACS site.

To send a message, press the nbutton (keylight comes on) then press one of the number buttons (0-9) to select the pre-programmed message text. If no message text has been programmed for the selected number button, the radio will display NO ENTRY and a low pitched tone sounds. A valid selection will permit the message text to appear in the display for a pre-

programmed time. After the time-out expires or the m button has been

pressed (the m button will override the time-out period), the message textis selected and will be transmitted to the site. If the site receives the

message properly when transmitted, a high pitched tone sounds and the n keylight remains lit. If the site does not receive the message properly, a low

pitched tone sounds and the nkeylight will blink.

If an incorrect message text was selected or the incorrect number button was pressed, the message text can be changed during the pre-programmed time- out period by pressing another number button. The message text selection

can also be cancelled by pressing the c button prior to the time-out period.

To view the currently selected message text after it has been transmitted,

press the nbutton and then the cbutton prior to the time-out period. If the message text was not sent successfully to the site, the text associated with the message will flash in the display.

EDACS CONVENTIONAL P1 SCAN

This feature permits the radio user to scan a pre-programmed conventional system and channel as a Priority 1 (P1) channel while the radio is selected for EDACS trunked system. If activity is detected on the conventional P1 channel, the radio will unmute and remain on this conventional channel for the programmable hang time.

The radio must be pre-programmed to designate a button for scan ON/OFF operation.

53

Image 53
Contents Orion Product Specification for CE Marked Equipment Table of Contents Table of Contents List of the possible hazards are Explosive Atmospheres Safety InformationInterference To Vehicular Electronic Systems Dynamite Blasting CapsUser Interface IntroductionOrion Mobile Radio System Model Front Panel SYSTEM/GROUP Channel Knob Power ON-OFF Volume KnobControls Ramp Control IndicatorsScan ON/OFF Scan ADD/DELETEOrion System Model Keypad KeypadKey Descriptions Standard Keycap ConfigurationOptional Keycap Configuration Entry see Selection Mode Rules ALM Primary Functions Quick AccessRadio Status Icons DisplayMessage Name Description MessagesTX Data WHC=1 FIX List Spkr on Call Queued Trunked Mode only Autokey Trunked Mode onlySystem Busy Trunked Mode only Alert TonesCarrier Control Timer Call Denied Trunked Mode onlyDual Control Switching OperationTurning on the Radio Selection Mode RulesU T H Direct AccessMenu N U K L G H T Press SEL Menu Item Information Feature Display Parameter Comment Settings SYS Scan Serial Number ROM 12 Hex Digits Example Feature Encryption DisplayFeature Encryption Data Stream Number Fields Features EnabledBIT Fields Possible Features System Selection SYSTEM/GROUP/CHANNEL SelectionGroup And Channel Selection Sending a Call Trunked Mode OperationReceiving a Call Receiving An Emergency Call Conventional FailsoftEmergency Operation Wide Area System Scan System Scan OperationDeclaring An Emergency Call ProScanTM ProSoundTMWhen ProSound/ProScan Is Enabled When Wide Area System Scan Is EnabledPriority System Scan Menu SelectionGroup Scan Operation Deleting Groups From a Scan List Adding Groups To a Scan ListPriority Group Scanning Nuisance DeleteTurning Scan on Receiving and Responding To An Individual Call Individual CallsTurning Scan OFF Page Sending An Individual Call Scat OperationTelephone Interconnect Calls Receiving a Telephone Interconnect Call Trunked Mode OnlySending a Telephone Interconnect Call Trunked Mode Only Dtmf Overdial/Conventional Mode Telephone Interconnect Programmable Entries Displays Mobile DataData On Operation Data OFF OperationExiting Data Calls Scan Lockout ModeSTATUS/MESSAGE Operation Data Lockout ModeStatus Operation Message Operation Edacs Conventional P1 ScanEmergency Operation Conventional Mode OperationDynamic Regroup Operation Receiving a Call Tone Encode Transmission Using 5-Tone Signalling for Emergency DeclarationScanning Conventional Channels Deleting Channels From a Scan List Adding Channels To a Scan ListTurning Scan OFF Turning Scan onSquelch Adjust Type 99 Decode Conventional Only Noise Blanker OperationMenu Selection Direct Mode Operation Conventional System Only Voice Modes Trunked or Conventional Mode OperationSIREN/LIGHT Operation Clear Modes AEGIS/ProVoice Digital ModeYes ERR=xxxx Error MessagesPage Displaying The Currently Used Cryptographic Key Number Transferring Keys Into The RadioTransmitting An Encrypted Call Key ZeroPrivate Operation Receiving An Encrypted Call Conventional Operation Outside Address Scanned Group CallsControl Switching Modes Switching ControlDual Control Operation Channel GuardSiren And Light Control Slaved Mode OperationIndependent Mode Operation Dual Control Audio Multiple Radio OperationChanging Selected Radio Shared Control Unit Display ModesAudio Modes First Come First Serve DisplayAudio Summed Audio First Come First ServeMacro KEY Operation Page Keypad Remapping Operating Rules and Regulations Glossary Site Group Or Subfleet Group Scan Individual Call QueueingController SystemTelephone Talk-aroundInter ConnectRadio Type Frequency Band Operators Name Emergency Group Operators Radio SetupWarranty Operating Tips Emergency Numbers