Orion LBI-38888K manual Adding Groups To a Scan List, Deleting Groups From a Scan List

Page 40

Adding Groups To A Scan List

1.With scan operation turned OFF, select the desired group to add to the selected Trunked system group scan list.

2.Press <or >on the SCAN add/delete control. The current priority status of the group will be displayed in column 1 of line one for a time- out period. If the group is not part of the scan list the status will be blank.

3.While the status is displayed press <to add the group to the scan list. "S" is displayed on line one.

4.Press < a second time to set the group to Priority 2. A "2" is displayed on line one.

5.Press <a third time to set the group to Priority 1. A "1" is displayed on line one. The priority level selection sequence only advances the group to next higher priority level and stops at priority level 1. To select a lower priority level, the group must be deleted from the scan list and then added back to the scan list. Each new group added to the scan list starts at the lowest priority. If the the Priority 1 and Priority 2 groups are already set and a new group is assigned as Priority 1 or Priority 2, the previously assigned group will change to non-priority scanning.

Deleting Groups From A Scan List

1.With scan operation turned OFF, select the desired group to delete from the selected trunked system's group scan list.

2.Press <or > on the SCAN add/delete control. The current status of the group is displayed for a time-out period.

3.Press >to delete the group from the scan list. "S", "2" or "1" turns OFF. Any group that is not in a trunked system group scan list will show a "blank" for the time period when it is the selected channel.

40

Image 40
Contents Orion Product Specification for CE Marked Equipment Table of Contents Table of Contents Safety Information List of the possible hazards are Explosive AtmospheresInterference To Vehicular Electronic Systems Dynamite Blasting CapsIntroduction User InterfaceOrion Mobile Radio System Model Front Panel Controls Power ON-OFF Volume KnobSYSTEM/GROUP Channel Knob Indicators Ramp ControlScan ON/OFF Scan ADD/DELETEKeypad Orion System Model KeypadOptional Keycap Configuration Standard Keycap ConfigurationKey Descriptions Entry see Selection Mode Rules Primary Functions Quick Access ALMDisplay Radio Status IconsMessages Message Name DescriptionTX Data WHC=1 FIX List Spkr on Autokey Trunked Mode only Call Queued Trunked Mode onlySystem Busy Trunked Mode only Alert TonesCall Denied Trunked Mode only Carrier Control TimerDual Control Switching OperationSelection Mode Rules Turning on the RadioDirect Access U T HMenu N U K L G H T Press SEL Menu Item Information Feature Display Parameter Comment Settings SYS Scan Feature Encryption Data Stream Feature Encryption DisplaySerial Number ROM 12 Hex Digits Example Features Enabled Number FieldsBIT Fields Possible Features SYSTEM/GROUP/CHANNEL Selection System SelectionGroup And Channel Selection Receiving a Call Trunked Mode OperationSending a Call Emergency Operation Conventional FailsoftReceiving An Emergency Call Declaring An Emergency Call System Scan OperationWide Area System Scan ProSoundTM ProScanTMWhen Wide Area System Scan Is Enabled When ProSound/ProScan Is EnabledPriority System Scan Menu SelectionGroup Scan Operation Adding Groups To a Scan List Deleting Groups From a Scan ListTurning Scan on Nuisance DeletePriority Group Scanning Turning Scan OFF Individual CallsReceiving and Responding To An Individual Call Page Scat Operation Sending An Individual CallSending a Telephone Interconnect Call Trunked Mode Only Receiving a Telephone Interconnect Call Trunked Mode OnlyTelephone Interconnect Calls Dtmf Overdial/Conventional Mode Telephone Interconnect Programmable Entries Mobile Data DisplaysData OFF Operation Data On OperationScan Lockout Mode Exiting Data CallsData Lockout Mode STATUS/MESSAGE OperationStatus Operation Edacs Conventional P1 Scan Message OperationDynamic Regroup Operation Conventional Mode OperationEmergency Operation Receiving a Call Using 5-Tone Signalling for Emergency Declaration Tone Encode TransmissionScanning Conventional Channels Adding Channels To a Scan List Deleting Channels From a Scan ListTurning Scan on Turning Scan OFFSquelch Adjust Noise Blanker Operation Type 99 Decode Conventional OnlyMenu Selection Direct Mode Operation Conventional System Only SIREN/LIGHT Operation Trunked or Conventional Mode OperationVoice Modes Yes AEGIS/ProVoice Digital ModeClear Modes Error Messages ERR=xxxxPage Transferring Keys Into The Radio Displaying The Currently Used Cryptographic Key NumberPrivate Operation Receiving An Encrypted Call Key ZeroTransmitting An Encrypted Call Scanned Group Calls Conventional Operation Outside AddressSwitching Control Control Switching ModesDual Control Operation Channel GuardIndependent Mode Operation Slaved Mode OperationSiren And Light Control Multiple Radio Operation Dual Control AudioChanging Selected Radio Shared Control Unit Display ModesFirst Come First Serve Display Audio ModesAudio Summed Audio First Come First ServeMacro KEY Operation Page Keypad Remapping Operating Rules and Regulations Glossary Group Or Subfleet Group Scan Individual Call Queueing SiteController SystemTalk-around TelephoneInter ConnectOperators Radio Setup Radio Type Frequency Band Operators Name Emergency GroupWarranty Emergency Numbers Operating Tips