Orion LBI-38888K manual Scanned Group Calls, Conventional Operation Outside Address

Page 70

If the last state of the radio was private mode, the private mode will be enabled on power up. Also the private mode will be enabled if forced operation has been programmed in the radio

If a group or channel is not programmed for private mode operation, PVT DIS will be displayed if an attempt is made to enable private transmit mode. It is not possible to operate on this group/channel in private mode.

If the radio is programmed for forced private transmit operation, FRCD PVT will be displayed if an attempt is made to disable private transmit mode. It is not possible to transmit on this group/channel in clear mode.

If the radio does not have the correct encryption key loaded, NO KEY # will be displayed and the call will not be transmitted.

3.Continue with standard transmission procedures. A private mode access tone will be heard when the PTT button is pressed.

Scanned Group Calls

Receiving a scanned group call is the same as receiving a selected group call. During the scan hang time, if the radio was programmed for autoselect, it will transmit back in the same mode it received the call. For example, if a clear group is entered in the scan list, it will only receive clear calls. If the same group was available in private and entered in the scan list, it can receive clear and private calls, provided autoselect was programmed in the radio. The user can select transmitting on the scanned or selected group. If a group is entered in the scan list more than once and in different modes (clear, digital, private), only the first occurrence of the group will be used.

Conventional Operation

Outside Address

The same outside address (works similar to Channel Guard operation) must be programmed in the transmitting and receiving radios when Aegis or ProVoice digital or private operation is enabled. If address is not correct, the radios will not communicate.

70

Image 70
Contents Orion Product Specification for CE Marked Equipment Table of Contents Table of Contents Interference To Vehicular Electronic Systems Safety InformationList of the possible hazards are Explosive Atmospheres Dynamite Blasting CapsIntroduction User InterfaceOrion Mobile Radio System Model Front Panel Controls Power ON-OFF Volume KnobSYSTEM/GROUP Channel Knob Scan ON/OFF IndicatorsRamp Control Scan ADD/DELETEKeypad Orion System Model KeypadOptional Keycap Configuration Standard Keycap ConfigurationKey Descriptions Entry see Selection Mode Rules Primary Functions Quick Access ALMDisplay Radio Status IconsMessages Message Name DescriptionTX Data WHC=1 FIX List Spkr on System Busy Trunked Mode only Autokey Trunked Mode onlyCall Queued Trunked Mode only Alert TonesDual Control Switching Call Denied Trunked Mode onlyCarrier Control Timer OperationSelection Mode Rules Turning on the RadioDirect Access U T HMenu N U K L G H T Press SEL Menu Item Information Feature Display Parameter Comment Settings SYS Scan Feature Encryption Data Stream Feature Encryption DisplaySerial Number ROM 12 Hex Digits Example Features Enabled Number FieldsBIT Fields Possible Features SYSTEM/GROUP/CHANNEL Selection System SelectionGroup And Channel Selection Receiving a Call Trunked Mode OperationSending a Call Emergency Operation Conventional FailsoftReceiving An Emergency Call Declaring An Emergency Call System Scan OperationWide Area System Scan ProSoundTM ProScanTMPriority System Scan When Wide Area System Scan Is EnabledWhen ProSound/ProScan Is Enabled Menu SelectionGroup Scan Operation Adding Groups To a Scan List Deleting Groups From a Scan ListTurning Scan on Nuisance DeletePriority Group Scanning Turning Scan OFF Individual CallsReceiving and Responding To An Individual Call Page Scat Operation Sending An Individual CallSending a Telephone Interconnect Call Trunked Mode Only Receiving a Telephone Interconnect Call Trunked Mode OnlyTelephone Interconnect Calls Dtmf Overdial/Conventional Mode Telephone Interconnect Programmable Entries Mobile Data DisplaysData OFF Operation Data On OperationScan Lockout Mode Exiting Data CallsData Lockout Mode STATUS/MESSAGE OperationStatus Operation Edacs Conventional P1 Scan Message OperationDynamic Regroup Operation Conventional Mode OperationEmergency Operation Receiving a Call Using 5-Tone Signalling for Emergency Declaration Tone Encode TransmissionScanning Conventional Channels Adding Channels To a Scan List Deleting Channels From a Scan ListTurning Scan on Turning Scan OFFSquelch Adjust Noise Blanker Operation Type 99 Decode Conventional OnlyMenu Selection Direct Mode Operation Conventional System Only SIREN/LIGHT Operation Trunked or Conventional Mode OperationVoice Modes Yes AEGIS/ProVoice Digital ModeClear Modes Error Messages ERR=xxxxPage Transferring Keys Into The Radio Displaying The Currently Used Cryptographic Key NumberPrivate Operation Receiving An Encrypted Call Key ZeroTransmitting An Encrypted Call Scanned Group Calls Conventional Operation Outside AddressDual Control Operation Switching ControlControl Switching Modes Channel GuardIndependent Mode Operation Slaved Mode OperationSiren And Light Control Changing Selected Radio Multiple Radio OperationDual Control Audio Shared Control Unit Display ModesAudio Summed First Come First Serve DisplayAudio Modes Audio First Come First ServeMacro KEY Operation Page Keypad Remapping Operating Rules and Regulations Glossary Controller Group Or Subfleet Group Scan Individual Call QueueingSite SystemInter Talk-aroundTelephone ConnectOperators Radio Setup Radio Type Frequency Band Operators Name Emergency GroupWarranty Emergency Numbers Operating Tips