Orion LBI-38888K manual SYSTEM/GROUP/CHANNEL Selection, System Selection

Page 32

SYSTEM/GROUP/CHANNEL SELECTION

In the following description of SYSTEM/GROUP/CHANNEL SELECTION, the term group is used for both group and channel.

The ORION SYSTEM/GROUP/CHANNEL knob and the RAMP control

,, . pair are programmable for maximum flexibility. If the SYSTEM/GROUP/CHANNEL knob is assigned to select groups, then the

RAMP control ,, . is assigned to select systems. If the SYSTEM/GROUP/CHANNEL knob is assigned to select systems, then the

RAMP control ,, .keys are assigned to select groups. System, group and channel selection is the primary function for these controls.

Either systems or groups can also be selected by entering the select mode and following the selection mode rules described earlier. The system select or group select modes are entered by pressing SYS or GRP, respectively,

from the standard receive mode. Using the RAMP control, ,. after entering a particular selection mode in this manner is the secondary function of these keys.

System Selection

Several methods, some of which depend on programming, can be used to select a new system. These procedures are presumed to be starting from the normal receive display.

METHOD 1 If system selection is programmed to the SYSTEM/ GROUP/CHANNEL knob, select a system by turning the SYSTEM/ GROUP/CHANNEL knob to the desired system position. The display registers the new system name on line one. If the wrap option is OFF and the knob is moved to a position greater than the number of programmed systems, the highest programmed system will remain selected.

METHOD 2 If system selection is programmed as the primary function of the RAMP control , and ., select a system by

pressing ,or .to scroll through the system list. The display registers the new system name on line one.

32

Image 32
Contents Orion Product Specification for CE Marked Equipment Table of Contents Table of Contents Safety Information List of the possible hazards are Explosive AtmospheresInterference To Vehicular Electronic Systems Dynamite Blasting CapsIntroduction User InterfaceOrion Mobile Radio System Model Front Panel SYSTEM/GROUP Channel Knob Power ON-OFF Volume KnobControls Indicators Ramp ControlScan ON/OFF Scan ADD/DELETEKeypad Orion System Model KeypadKey Descriptions Standard Keycap ConfigurationOptional Keycap Configuration Entry see Selection Mode Rules Primary Functions Quick Access ALMDisplay Radio Status IconsMessages Message Name DescriptionTX Data WHC=1 FIX List Spkr on Autokey Trunked Mode only Call Queued Trunked Mode onlySystem Busy Trunked Mode only Alert TonesCall Denied Trunked Mode only Carrier Control TimerDual Control Switching OperationSelection Mode Rules Turning on the RadioDirect Access U T HMenu N U K L G H T Press SEL Menu Item Information Feature Display Parameter Comment Settings SYS Scan Serial Number ROM 12 Hex Digits Example Feature Encryption DisplayFeature Encryption Data Stream Features Enabled Number FieldsBIT Fields Possible Features SYSTEM/GROUP/CHANNEL Selection System SelectionGroup And Channel Selection Sending a Call Trunked Mode OperationReceiving a Call Receiving An Emergency Call Conventional FailsoftEmergency Operation Wide Area System Scan System Scan OperationDeclaring An Emergency Call ProSoundTM ProScanTMWhen Wide Area System Scan Is Enabled When ProSound/ProScan Is EnabledPriority System Scan Menu SelectionGroup Scan Operation Adding Groups To a Scan List Deleting Groups From a Scan ListPriority Group Scanning Nuisance DeleteTurning Scan on Receiving and Responding To An Individual Call Individual CallsTurning Scan OFF Page Scat Operation Sending An Individual CallTelephone Interconnect Calls Receiving a Telephone Interconnect Call Trunked Mode OnlySending a Telephone Interconnect Call Trunked Mode Only Dtmf Overdial/Conventional Mode Telephone Interconnect Programmable Entries Mobile Data DisplaysData OFF Operation Data On OperationScan Lockout Mode Exiting Data CallsData Lockout Mode STATUS/MESSAGE OperationStatus Operation Edacs Conventional P1 Scan Message OperationEmergency Operation Conventional Mode OperationDynamic Regroup Operation Receiving a Call Using 5-Tone Signalling for Emergency Declaration Tone Encode TransmissionScanning Conventional Channels Adding Channels To a Scan List Deleting Channels From a Scan ListTurning Scan on Turning Scan OFFSquelch Adjust Noise Blanker Operation Type 99 Decode Conventional OnlyMenu Selection Direct Mode Operation Conventional System Only Voice Modes Trunked or Conventional Mode OperationSIREN/LIGHT Operation Clear Modes AEGIS/ProVoice Digital ModeYes Error Messages ERR=xxxxPage Transferring Keys Into The Radio Displaying The Currently Used Cryptographic Key NumberTransmitting An Encrypted Call Key ZeroPrivate Operation Receiving An Encrypted Call Scanned Group Calls Conventional Operation Outside AddressSwitching Control Control Switching ModesDual Control Operation Channel GuardSiren And Light Control Slaved Mode OperationIndependent Mode Operation Multiple Radio Operation Dual Control AudioChanging Selected Radio Shared Control Unit Display ModesFirst Come First Serve Display Audio ModesAudio Summed Audio First Come First ServeMacro KEY Operation Page Keypad Remapping Operating Rules and Regulations Glossary Group Or Subfleet Group Scan Individual Call Queueing SiteController SystemTalk-around TelephoneInter ConnectOperators Radio Setup Radio Type Frequency Band Operators Name Emergency GroupWarranty Emergency Numbers Operating Tips