Heat Controller DMC36CA-1 Function of Remote Control, Wireless LCD Remote Control, Nd F Button

Page 11

Function of Remote Control

Function of Remote Control

1.Wireless LCD Remote Control

Signal transmitter

5

 

 

1

6

 

 

 

 

 

 

3

4

 

 

 

2

 

 

10

 

CANCEL

 

 

 

9

7

OFF

SET

ON

12

11

 

AUTO CLEAN

8

 

 

17

 

° C/° F

18

13

 

 

 

 

 

14

15

 

 

 

 

16

Flip-up door (opened)

Operation Mode

Cooling Operation

Auto Operation

Healthy Dehumidification Operation

1. START/STOP BUTTON

Operation starts when this button is pressed and stops when the button is pressed again.

2. OPERATION MODE SELECTION BUTTON Used to select the operation mode.

3.ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature.

4.INDOOR FAN SPEED SELECTOR Used to select fan speed in four steps

low, medium and high.

5. JET COOL

Used to start or stop the speed cooling.(speed cooling operates super high fan speed in cooling mode.)

6. AUTO SWING BUTTON

Used to stop or start louver movement and set the desired up/down airflow direction.

7.ON/OFF TIMER BUTTONS

Used to set the time of starting and stopping opera- tion.

8.TIME SETTING BUTTONS Used to adjust the time.

9.TIMER SET/CANCEL BUTTON

Used to set the timer when the desired time is obtained and to cancel the Timer operation.

10.SLEEP MODE AUTO BUTTON

Used to set Sleep Mode Auto operation.

11.AIR CIRCULATION BUTTON

Used to circulate the room air without cooling.

12.ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature.

13.PLASMA AIR CLEAN BUTTON

Used to start or stop the plasma-purification func- tion.

14.HORIZONTAL AIRFLOW DIRECTION CONTROL BUTTON (OPTIONAL)

Used to set the desired horizontal airflow direction.

15.RESET BUTTON

Used prior to resetting time.

16.2nd F Button

Used prior to using modes printed in blue at the bot- tom of buttons.

17.AUTO CLEAN (OPTIONAL) Used to set Auto Clean mode.

18.°C/°F SWITCH BUTTON

Used to switch temperature reading from Centigrade to Fahrenheit.

The wireless remote controller do not operate the swirl mode.

Service Manual 11

Image 11
Contents Ceiling Cassette Type Single-Zone Air Conditioning Table of Contents Installation Safety PrecautionsDo not let electric parts of the product get wet Be cautious when unpacking and installing the productBe sure the installation area does not deteriorate with age OperationalBe cautious that water could not enter the product Do not step on or put anyting on the product. outdoor units ThinnerFeatures & Benefits Two Thermistor Control Swirl SwingSpace Control Auto Restart OperationWater Drain Pump Time Delay Safety FunctionZero Standby Power High Ceiling OperationCeiling Cassette List of FunctionsNd F Button Function of Remote ControlWireless LCD Remote Control Wired LCD Remote Control DMC36CA-1 SpecificationsOutdoor Unit Indoor Units Dimensional DrawingsModel No. DMC24CA-1 Model No. DMC36CA-1 DMC24CA-1 / DMC36CA-1 Wiring DiagramsIndoor Unit DMC36CA-1 Outdoor UnitDMC24CA-1 Cooling Only Models Refrigerant Cycle DiagramsOutdoor Unit InstallationSelect the best location Indoor UnitSettlement of outdoor unit Indoor Unit InstallationWiring Connection Air conditioner unit Piping side Installation of Decoration PanelHeat Insulation Heat Insulation and pipingsDrain test Drain Pipe WorkDrain Piping of Ceiling Cassette Test running Precautions in Test RUNEvaluation of the performance Connection of power supplyTwo Thermistor System Optional OperationRemote Controller Adjusting air volume to the height of ceilingProcedure Wiring designTrouble analysis Troubleshooting GuideCycle Troubleshooting Guide Trouble Electronic Parts Troubleshooting GuideProduct doesnt operate with the remote controller When cooling does not operate When indoor Fan does not operate Trouble 5 When Vertical Louver does not operate Self-diagnosis Function Indoor ErrorOutdoor Error Error IndicatorCheck Point Troubleshooting CH01, CH02, CH06Troubleshooting CH03 Drain pump Float switch Open Drain pump power input Troubleshooting CH04Troubleshooting CH05, CH53 Troubleshooting CH24, CH25 Constant Troubleshooting CH32, CH33Inverter Troubleshooting CH41, CH44, CH45, CH46, CH47, CH65 Troubleshooting Guide Troubleshooting CH61, CH62 Way Valve Liguid Side Way Valve Gas Side Way ValveSet the liquid side valve to the closed position ProcedurePumping down Air purging of the charge hoseAll amount of refrigerant leaked Mount the valve caps and the service port capsEvacuation Connect the gauge to the charging cylinder Mount the valve stem nuts and the service port nutGas Charging After EvacuationMain P.C.B ASM Electronic Control Device03/19/07
Related manuals