Troubleshooting Guide
TroubleshootingCH61,CH62
Display | Title | Cause of error | Check point & Normal condition | |
code | ||||
|
|
| ||
|
|
|
| |
61 | Condenser | • Condenser pipe sensor | • Check the load condition. | |
pipe sensor | ||||
detected high | ||||
• Check the sensor of Condenser pipe sensor. | ||||
| temp. high | |||
| temp.(65°C)(149°F) | |||
|
| |||
|
|
| ||
|
|
|
| |
| Heat sink sensor | • Heat sink sensor | • Check the fan is locked. | |
62 | detected high | |||
temp. high | • Check the sensor of heat sink. | |||
| temp.(85°C)(185°F) | |||
|
|
| ||
|
|
|
|
|
| Heat Sink temp. |
|
|
Toff ° C |
|
|
|
|
T2 ° C |
|
|
|
|
T1 ° C |
|
|
|
|
COMP Frequency | Normal | Normal | OFF | Normal |
(Hz) |
|
|
|
|
Check Point
• CH 61
1.Check the install condition for over load. (Refrigerant, Pipe length, Blocked, … )
• CH 62
1.Check the fan is locked.
2.Check the Outdoor temp. is very high.
46Ceiling Cassette Air Conditioner