Heat Controller DMC24CA-1, DMC36CA-1 manual Swirl Swing, Space Control, Auto Restart Operation

Page 8

Features & Benefits

Swirl Swing

-It is the function for comfort cooling/heating operation.

-The diagonal two louvers are opened the more larger than the other louvers.

After one minute, it is opposite.

Comparison of Floor

4- Open(Conventional)

Swirl Swing(New)

Temp. Distribution(20° C)

 

 

 

 

 

 

2.4%

 

 

 

 

100% Improved

4.8%

Comparison of Air Flow Types

 

 

 

 

 

 

 

 

 

 

 

 

4- Open(Conventional)

 

Swirl Swing(New)

 

 

 

 

 

 

 

Vane 2

Vane 1

 

 

 

 

Vane 1

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

Close

Open

Close

Open

Close

 

 

 

 

 

Vane 2

 

 

 

 

Vane 2

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

Open

Close

Open

Close

Open

 

 

 

 

 

Vane 3

 

 

 

 

Vane 3

 

 

 

 

 

 

 

Vane 1

 

 

 

 

Open

 

Close

Open

Close

Open

Close

 

 

 

 

Vane 4

 

 

 

 

Vane 4

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

Open

Close

Open71

Close

Open

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time

 

 

Time

 

 

 

 

 

 

 

 

Vane 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vane 3

Space Control

Vanes angle can be controlled by pair, considering its installation environment.

-For example direct drafts can be annoying, leading to discomfort and reduced productivity vane control helps to eliminate this problem.

-Easily controlled by wired remote control.

-Air Flow can be controlled easily regarding any space environment.

Auto Restart Operation :

-Whenever there is electricity failure to the unit, and after resumption of the power, unit will start in the same mode prior to the power failure. Memorized condition are on / off condition, operating mode, set temperature and fan speed.The unit will memorize the above conditions and start with same memorized condition.

Two Thermistor Control :

- There may be a significant difference between the temperature taken at the installed product and indoor tem- perature. Two thermistor control provides option to control temperature by referring any of the two tempera- tures. With the help of the slide switch at the back of the LCD wired remote controller, selection of the desired thermistor for controlling the unit can be done. One thermistor is in the Indoor unit & the other one is in the LCD wired remote.

8Ceiling Cassette Air Conditioner

Image 8
Contents Ceiling Cassette Type Single-Zone Air Conditioning Table of Contents Safety Precautions InstallationBe cautious when unpacking and installing the product Be sure the installation area does not deteriorate with ageOperational Do not let electric parts of the product get wetBe cautious that water could not enter the product Thinner Do not step on or put anyting on the product. outdoor unitsFeatures & Benefits Swirl Swing Space ControlAuto Restart Operation Two Thermistor ControlTime Delay Safety Function Zero Standby PowerHigh Ceiling Operation Water Drain PumpList of Functions Ceiling CassetteNd F Button Function of Remote ControlWireless LCD Remote Control Wired LCD Remote Control Specifications DMC36CA-1Outdoor Unit Dimensional Drawings Indoor UnitsModel No. DMC24CA-1 Model No. DMC36CA-1 DMC24CA-1 / DMC36CA-1 Wiring DiagramsIndoor Unit DMC36CA-1 Outdoor UnitDMC24CA-1 Refrigerant Cycle Diagrams Cooling Only ModelsInstallation Select the best locationIndoor Unit Outdoor UnitIndoor Unit Installation Settlement of outdoor unitWiring Connection Installation of Decoration Panel Air conditioner unit Piping sideHeat Insulation and pipings Heat InsulationDrain test Drain Pipe WorkDrain Piping of Ceiling Cassette Precautions in Test RUN Test runningConnection of power supply Evaluation of the performanceOptional Operation Two Thermistor SystemAdjusting air volume to the height of ceiling ProcedureWiring design Remote ControllerTrouble analysis Troubleshooting GuideCycle Troubleshooting Guide Electronic Parts Troubleshooting Guide TroubleProduct doesnt operate with the remote controller When cooling does not operate When indoor Fan does not operate Trouble 5 When Vertical Louver does not operate Indoor Error Outdoor ErrorError Indicator Self-diagnosis FunctionTroubleshooting CH01, CH02, CH06 Check PointTroubleshooting CH03 Troubleshooting CH04 Drain pump Float switch Open Drain pump power inputTroubleshooting CH05, CH53 Troubleshooting CH24, CH25 Constant Troubleshooting CH32, CH33Inverter Troubleshooting CH41, CH44, CH45, CH46, CH47, CH65 Troubleshooting Guide Troubleshooting CH61, CH62 Way Valve Way Valve Liguid Side Way Valve Gas SideProcedure Pumping downAir purging of the charge hose Set the liquid side valve to the closed positionAll amount of refrigerant leaked Mount the valve caps and the service port capsEvacuation Mount the valve stem nuts and the service port nut Gas ChargingAfter Evacuation Connect the gauge to the charging cylinderElectronic Control Device Main P.C.B ASM03/19/07