Safety Presautions

Do not store or use flammable gas or com- bustibles near the product.

If strange sounds, or small or smoke comes from product. Turn the breaker off or discon- nect the power supply cable.

• There is risk of fire or failure of product.

• There is risk of electric shock or fire.

Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)

Be cautious that water could not enter the product.

• There is risk of physical injury, electric shock, or prod- • There is risk of fire, electric shock, or product damage. uct failure.

Installation

Always check for gas (refrigerant) leakage after installation or repair of product.

Install the drain hose to ensure that water is drained away properly.

• Low refrigerant levels may cause failure of product.

• A bad connection may cause water leakage.

Service Manual 5

Image 5
Contents Ceiling Cassette Type Single-Zone Air Conditioning Table of Contents Installation Safety PrecautionsBe sure the installation area does not deteriorate with age Be cautious when unpacking and installing the productOperational Do not let electric parts of the product get wetBe cautious that water could not enter the product Do not step on or put anyting on the product. outdoor units ThinnerFeatures & Benefits Space Control Swirl SwingAuto Restart Operation Two Thermistor ControlZero Standby Power Time Delay Safety FunctionHigh Ceiling Operation Water Drain PumpCeiling Cassette List of FunctionsNd F Button Function of Remote ControlWireless LCD Remote Control Wired LCD Remote Control DMC36CA-1 SpecificationsOutdoor Unit Indoor Units Dimensional DrawingsModel No. DMC24CA-1 Model No. DMC36CA-1 DMC24CA-1 / DMC36CA-1 Wiring DiagramsIndoor Unit DMC36CA-1 Outdoor UnitDMC24CA-1 Cooling Only Models Refrigerant Cycle DiagramsSelect the best location InstallationIndoor Unit Outdoor UnitSettlement of outdoor unit Indoor Unit InstallationWiring Connection Air conditioner unit Piping side Installation of Decoration PanelHeat Insulation Heat Insulation and pipingsDrain test Drain Pipe WorkDrain Piping of Ceiling Cassette Test running Precautions in Test RUNEvaluation of the performance Connection of power supplyTwo Thermistor System Optional OperationProcedure Adjusting air volume to the height of ceilingWiring design Remote ControllerTrouble analysis Troubleshooting GuideCycle Troubleshooting Guide Trouble Electronic Parts Troubleshooting GuideProduct doesnt operate with the remote controller When cooling does not operate When indoor Fan does not operate Trouble 5 When Vertical Louver does not operate Outdoor Error Indoor ErrorError Indicator Self-diagnosis FunctionCheck Point Troubleshooting CH01, CH02, CH06Troubleshooting CH03 Drain pump Float switch Open Drain pump power input Troubleshooting CH04Troubleshooting CH05, CH53 Troubleshooting CH24, CH25 Constant Troubleshooting CH32, CH33Inverter Troubleshooting CH41, CH44, CH45, CH46, CH47, CH65 Troubleshooting Guide Troubleshooting CH61, CH62 Way Valve Liguid Side Way Valve Gas Side Way ValvePumping down ProcedureAir purging of the charge hose Set the liquid side valve to the closed positionAll amount of refrigerant leaked Mount the valve caps and the service port capsEvacuation Gas Charging Mount the valve stem nuts and the service port nutAfter Evacuation Connect the gauge to the charging cylinderMain P.C.B ASM Electronic Control Device03/19/07