Wiring Diagrams

Wiring Diagrams

1. Indoor Unit

DMC24CA-1 / DMC36CA-1

 

Connector Number

Location

CN-POWER

AC power supply

CN-MOTOR

BLDC fan motor output

CN-DPUMP

Drain pump output

CN-DISP

Display

CN-FLOAT

Float switch input

CN-REMO

Remote control

CN-CC

Dry-contact

CN-ROOM

Room sensor

CN-PIPE1

In-pipe thermistor

CN-PIPE2

Out-pipe thermistor

CN-GRILL

Elevation grille

 

 

CN-HVB

HVB Ass'y (Air cleaner)

18Ceiling Cassette Air Conditioner

Image 18
Contents Ceiling Cassette Type Single-Zone Air Conditioning Table of Contents Safety Precautions InstallationOperational Be cautious when unpacking and installing the productBe sure the installation area does not deteriorate with age Do not let electric parts of the product get wetBe cautious that water could not enter the product Thinner Do not step on or put anyting on the product. outdoor unitsFeatures & Benefits Auto Restart Operation Swirl SwingSpace Control Two Thermistor ControlHigh Ceiling Operation Time Delay Safety FunctionZero Standby Power Water Drain PumpList of Functions Ceiling CassetteFunction of Remote Control Wireless LCD Remote ControlNd F Button Wired LCD Remote Control Specifications DMC36CA-1Outdoor Unit Dimensional Drawings Indoor UnitsModel No. DMC24CA-1 Model No. DMC36CA-1 Wiring Diagrams Indoor UnitDMC24CA-1 / DMC36CA-1 Outdoor Unit DMC24CA-1DMC36CA-1 Refrigerant Cycle Diagrams Cooling Only ModelsIndoor Unit InstallationSelect the best location Outdoor UnitIndoor Unit Installation Settlement of outdoor unitWiring Connection Installation of Decoration Panel Air conditioner unit Piping sideHeat Insulation and pipings Heat InsulationDrain Pipe Work Drain Piping of Ceiling CassetteDrain test Precautions in Test RUN Test runningConnection of power supply Evaluation of the performanceOptional Operation Two Thermistor SystemWiring design Adjusting air volume to the height of ceilingProcedure Remote ControllerTroubleshooting Guide Cycle Troubleshooting GuideTrouble analysis Electronic Parts Troubleshooting Guide TroubleProduct doesnt operate with the remote controller When cooling does not operate When indoor Fan does not operate Trouble 5 When Vertical Louver does not operate Error Indicator Indoor ErrorOutdoor Error Self-diagnosis FunctionTroubleshooting CH01, CH02, CH06 Check PointTroubleshooting CH03 Troubleshooting CH04 Drain pump Float switch Open Drain pump power inputTroubleshooting CH05, CH53 Troubleshooting CH24, CH25 Troubleshooting CH32, CH33 InverterConstant Troubleshooting CH41, CH44, CH45, CH46, CH47, CH65 Troubleshooting Guide Troubleshooting CH61, CH62 Way Valve Way Valve Liguid Side Way Valve Gas SideAir purging of the charge hose ProcedurePumping down Set the liquid side valve to the closed positionMount the valve caps and the service port caps EvacuationAll amount of refrigerant leaked After Evacuation Mount the valve stem nuts and the service port nutGas Charging Connect the gauge to the charging cylinderElectronic Control Device Main P.C.B ASM03/19/07
Related manuals
Manual 27 pages 9.94 Kb