Troubleshooting Guide
TroubleshootingCH24,CH25
Display | Title | Cause of error | Check point & Normal condition | |
code | ||||
|
|
| ||
|
|
|
| |
24 | Press S/W Open | • Low / High press | • Check the connection of “CN_Press”. | |
|
| S/W open. | • Check the components. | |
|
|
|
| |
25 | Input voltage | • Abnormal Input voltage | • Check the power source. | |
(140Vac , 300Vac . | • Check the components. | |||
|
| |||
|
|
|
|
Check Point
• CH 24
1.Check the connection of “CN_PRESS”
2.Check the install condition for over load.
3.Check the SVC V/V open.
4.Check the leakage of refrigerant.
• CH 25
1.Check the power source.
2.Check the components
(Trans1, B/Diode, Diode, Resistance)
42Ceiling Cassette Air Conditioner