TROUBLESHOOTING AND REPAIR |
TROUBLESHOOTING GUIDE - Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
(SYMPTOMS) | MISADJUSTMENTS(S) | COURSE OF ACTION |
|
|
|
| OUTPUT PROBLEMS |
|
Return to
Return to Section TOC
Return to Section TOC
Return
Return to Master TOC
Return to Master TOC
No weld output and no auxiliary out- 1. The generator brushes may be
put - engine runs normally.worn or faulty. See the Main- tenance section of this manual or contact your local Lincoln Electric Authorized Field Ser- vice Facility.
1.Perform the Rotor and Flashing Voltage Test.
2.The field capacitor (C1) or bridge (D1) may be faulty. Test or replace.
3.Test the rheostat (R1). Normal resistance is 3.3 ohms.
4.The rotor may be faulty. Perform the Rotor Resistance Test.
Return to Section TOC
Return to Master TOC
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call