TROUBLESHOOTING AND REPAIR |
TROUBLESHOOTING GUIDE - Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS |
| POSSIBLE AREAS OF |
| RECOMMENDED | |||
(SYMPTOMS) |
| MISADJUSTMENTS(S) |
| COURSE OF ACTION | |||
|
|
|
|
| |||
|
| OUTPUT PROBLEMS |
| ||||
|
|
|
| ||||
Low weld output and low auxiliary | 1. The generator brushes may be | 1. | Perform the Rotor Voltage Test. | ||||
output. |
| worn. See the Maintenance sec- | 2. | If the rotor voltage is low, the field | |||
|
| tion | of this | manual or | contact | ||
|
| your | local | Lincoln | Electric |
| capacitor (C1) or bridge (D1) may |
|
|
| be faulty. Test or replace. | ||||
|
| Authorized Field Service Facility. |
| ||||
|
|
|
| ||||
| 2. | The | engine | RPM may | be low. | 3. | Check the rheostat (R1). Normal |
|
|
|
|
|
|
| resistance is 3.3 ohm. |
|
|
|
|
|
| 4. | The rotor may be faulty. Perform |
|
|
|
|
|
|
| the Rotor Resistance Test. |
|
|
|
|
|
| 5. | The engine RPM may be low. |
|
|
|
|
|
|
| Perform the Engine Throttle |
|
|
|
|
|
|
| Adjustment Test. |
|
|
|
|
|
| 6. | If engine idle RPM is okay, the |
|
|
|
|
|
|
| engine may have lost horsepow- |
|
|
|
|
|
|
| er and be in need of major repair. |
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call