TROUBLESHOOTING AND REPAIR |
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115 VAC SUPPLY)
HIGH IDLE – NO LOAD
1 Period = 16.2 ms @ 3700 rpm
CH1
0 volts
50 volts | 5 ms |
This is the typical AC output voltage generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division represents 5 milliseconds in time.
Note: Scope probes connected at machine 115 VAC receptacle.
SCOPE SETTINGS
Volts/Div | 50V/Div. |
Horizontal Sweep | 5 ms/Div. |
Coupling | DC |
Trigger | Internal |
|
|