Lincoln Electric IM586-B manual Mounting Synergic 7F Wire Drive Unit

Page 11

A-3

INSTALLATION

A-3

 

 

 

Mounting Synergic 7F Wire Drive Unit

Mount the wire feed unit by means of the insulated mounting bracket attached to the bottom of the gearbox. Reference L9777 (included with Drive unit) to find the size and location of the mounting holes. The gearbox assembly is electrically “hot” when the gun trigger is pressed. Therefore, make cer- tain the gearbox does not come in contact with the structure on which the unit is mounted.

The wire feed unit should be mounted so that the drive rolls are in a vertical plane so dirt will not collect in the drive roll area. Position the mechanism so it will point down at about a 45° angle so the wire feed gun cable will not be bent sharply as it comes from the unit.

Note: The K1565-1 Control Box must be used with the K679 drives.

Mounting the STT-10 Control Box (K1565-2) (Boom Model)

Mounting the STT-10 Control Box (K1565-2)

(Removed from the wire drive unit.) (See Figure A.3)

Remove reed switch energizer assembly which includes: 4-pin connections, energizer spacer, insulation, mounting screws and washers from reel stand.

Mount the reed switch energizer assembly on the mounting bracket (G2868) as shown In Figure A.3. Then install mounting bracket G2868 to the rear of STT-10 control box. Secure it on the sides of box with (4) # 10-3/8” long screws.

FIGURE A.3

CONTROL BOX AND REED SWITCH

ENERGIZER ASSEMBLY REMOVE

FROM REEL STAND AND ADDED TO

MOUNTING BRACKET G2868

The STT-10 Boom Model has two keyhole slots and one bottom slot for mounting. See Figure A.2 for the size and

location of these slots. Mount the box at some convenient

location close to the wire drive unit which will enable the 2.62 desired control cable to reach between the control box and

the drive unit.

FIGURE A.2

BOLT PATTERN FOR SWITCH ENERGIZER ASSEMBLY, DRILL (4) HOLES IN MOUNTING BRACKET

CLEARANCE

10.50

.50

FOR 1/4 BOLT

 

 

13.75

14.00

 

 

12.75

10.00

 

2.63

2.63

 

5.25

14.50

 

CLEARANCE FOR 1/4 BOLT

a)Drill the required holes in the mounting surface, partially Install 1/4-20 screws.

b)Mount the box.

c)Tighten the screws.

Connecting Wire Drive Unit to Control Box.

One K1567-“L” head to control cable is needed to connect between the control box and the wire drive.

K1567-“L” Includes a control cable with 14-pin MS style connec- tion on each end, and a weld cable (rated 300 amps, 60% duty cycle) to route between the wire drive and the control box. Avaialble in lengths “L” of 16,20 or 25 ft. (4.9, 6.1m or 7.6m).

a) Making certain the cables are protectedfrom any sharp corners

which may damage their jackets, mount the cable assembly

along the boom so the end with the female amphenol connector

pins is at the wire feed unit.

a)Drill the required holes in the mounting surface, partially Install 1/4-20 screws.

b)Mount the box.

c)Tighten the screws.

b) Take the cables and connect the 14 pin cable between the 14 pin

receptacles on the wire drive unit and 14 pin receptacle on the

STT-10 Control Box.

c) Take electrode cable thatʼs part of the cable and connect one end

of the ½ connection bolt on the front of wire drive and the other

end to one side of the energizer assembly.

STT-10

Image 11
Contents IM586-B California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents P312 Series Diagrams Section FVii STT-10 InstallationGeneral Description Recommended Processes and Equipment Safety PrecautionsMounting the 10 Series Wire Drive Unit Mounting the STT-10 Control Box K1565-2 Boom Model Mounting Synergic 7F Wire Drive UnitConnecting Wire Drive Unit to Control Box Electrode Routing Wire Drive Speed Range SelectionControl Speed Range Setting Series Wire Drive Ratio SelectionElectric Shock can kill Wire Feed Drive Roll KitsProcedure to Install Drive Roll and Wire Guides Synergic 7F 4-Roll Kits KP655 and KP656Gmaw Guns GUN Connections GeneralGUN and Cable Assemblies with Standard Connection GUN and Cable Assemblies with FAST-MATE ConnectionGmaw Shielding Gas Synergic 7F Wire Drives K679Water Connections for Water Cooled Guns Gun Cable Connection with Fast-Mate ConnectionInput Cable STT-10 Control to Power Source Electrical InstallationMaterials Required for bench to boom conversion Optional Features InstallationDual Procedure Switch Options Boom and Bench ConversionsOperating Instructions STT-10 Control DIP Switch SetupOperation Range Lockout Mode Selection Step Trigger Mode Operation SelectionSecurity Mode Selection Robotics Mode SelectionKeypad and Display Description Power-Down SaveKeypad and Display Operation Operation KeysDisplay Control Keys Trigger Mode SelectionTrigger Mode Select Key Acceleration Selection Security ModeFigure B.1 Wire Reel Loading READI-REELS, Spools or CoilsDrive Roll Pressure Setting Feeding Electrode and Brake AdjustmentMaking a Weld Procedure for Setting Angle of FeedplateGAS Guard Regulator Setting Display Prompt or Error Wire Reel ChangingWire Feed Overload Protection Explanation of Prompting and Error MessagesSolid & Cored Steel Electrode Driven AccessoriesRoll DH Drive K1758-L Input Cable Assem BLY K683-1 Dual Procedure SwitchK683-3 Dual Procedure Switch K1558-1 Remote Switch Interface ModuleK206, K289, and K309 GUN Adapters for 10 Series Wire Drive HeadsCoil Adapter Magnum 200/300/400 GunsGUN and Cable Assemblies K1634-1 Wire Reel Enclosure KITMaintenance MaintenanceHOW to USE Troubleshooting Guide TroubleshootingContact your local Lincoln Authorized Field Service Facility Contact your local Lincoln Authorized Field Service FacilityTroubleshooting Damaged encoder p.c. board Troubleshooting Electric Shock can kill Procedure for Replacing PC BoardsDiagrams Diagrams Diagrams Connection Diagrams Dimension Print Bench Model Dimension Print Boom Model Control Box STT-10 STT-10 Precaucion Warnung