Lincoln Electric IM586-B manual Step Trigger Mode Operation Selection, Security Mode Selection

Page 19

B-2

OPERATION

B-2

 

 

 

4-Step Trigger Mode Operation Selection

The STT-10 Control is set up for 4-Step Trigger mode operation with or without weld current interlock by set- ting S1 DIP switch 5 (Labeled “4”).

When 4-Step trigger mode is selected on the STT-10 keypad (See Keypad and Display Operation in this section) S1 DIP switch setting determines the 4-step trigger operation:

S1 switch 5 OFF = 4-Step with current interlock operation: (As shipped)

 

 

Head

 

M 4

S R

L

 

ON

 

 

 

 

 

 

 

 

 

 

 

S1

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S1

 

 

 

 

 

 

 

 

 

 

 

 

1)Closing Trigger initiates gas preflow time followed by Run-in speed and strike voltage until arc strike initiates welding.

2)Opening Trigger after welding arc is established continues welding with weld current interlock. (Breaking arc stops the feeder operation).

3)Reclosing Trigger continues welding but shuts off current interlock function.

4)Reopening Trigger stops wire feed and initiates burnback time, then gas postflow time.

S1 switch 5 ON = 4-Step without current interlock

operation:

Head

ON

 

 

 

 

 

 

 

M 4

S R

L

S1

 

1

2

 

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)Closing Trigger initiates gas flow.

2)Opening Trigger initiates gas preflow timer followed by Run-in speed and strike voltage until arc strike initiates welding. (Trigger is released before arc is struck, but once established breaking arc stops the feeder operation).

3)Reclosing Trigger stops wire feed and initiates burnback time, then gas postflow time.

4)Reopening Trigger stops gas flow if, or when, post- flow time is over.

Security Mode Selection

The STT-10 Control is set up for Security Mode (See “Security Mode” in this section) by setting S1 DIP Switch 6 (Labeled “S”):

S1 switch 6 ON = Security mode ON

 

 

Head

 

M 4

S R

L

 

ON

 

 

 

 

 

 

 

S1

 

1

2

 

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S1 switch 6 OFF = Security mode OFF (as shipped)

 

 

Head

 

M 4

S R

L

 

ON

 

 

 

 

 

 

 

S1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

 

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Robotics Mode Selection

The STT-10 control is set up for Robotics Mode by setting the S1 DIP Switch 7 (Labeled “R”). For Robotics Interface Mode to operate, a K1561-1 Robotics Interface Module must be installed.

S1 switch 7 ON = Robotics mode ON

 

 

Head

 

M 4

S R

L

 

ON

 

 

 

 

 

 

 

S1

 

1

2

 

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S1 switch 7 OFF = Robotics mode OFF (As shipped)

 

Head

 

M 4

S R

L

 

ON

 

 

 

 

 

 

 

S1

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

 

3

4

5

6

7

8

 

S1

Range Lockout Mode Selection

The STT-10 control is set up for lockout of the Range control (See Range Control in this section) by setting S1 DIP Switch 8 (Labeled “L”).

S1 switch 8 ON = Range Lockout mode ON

 

Head

 

M 4

S R

L

 

ON

 

 

 

 

 

 

 

S1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

 

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S1

When Range Lockout mode is selected, the Range Key is disabled, and all previously selected ranges for peak current, background current, and wire feed speed are still enabled. To readjust the ranges, the Range Lockout mode must be disabled.

S1 switch 8 OFF = Range Lockout mode OFF (As shipped)

 

 

Head

 

M 4

S R

L

 

ON

 

 

 

 

 

 

 

S1

 

1

2

 

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STT-10

Image 19
Contents IM586-B California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Vii Diagrams Section FP312 Series General Description InstallationSTT-10 Mounting the 10 Series Wire Drive Unit Safety PrecautionsRecommended Processes and Equipment Connecting Wire Drive Unit to Control Box Mounting Synergic 7F Wire Drive UnitMounting the STT-10 Control Box K1565-2 Boom Model Electrode Routing Wire Drive Speed Range SelectionControl Speed Range Setting Series Wire Drive Ratio SelectionElectric Shock can kill Wire Feed Drive Roll KitsProcedure to Install Drive Roll and Wire Guides Synergic 7F 4-Roll Kits KP655 and KP656Gmaw Guns GUN Connections GeneralGUN and Cable Assemblies with Standard Connection GUN and Cable Assemblies with FAST-MATE ConnectionGmaw Shielding Gas Synergic 7F Wire Drives K679Water Connections for Water Cooled Guns Gun Cable Connection with Fast-Mate ConnectionInput Cable STT-10 Control to Power Source Electrical InstallationMaterials Required for bench to boom conversion Optional Features InstallationDual Procedure Switch Options Boom and Bench ConversionsOperation STT-10 Control DIP Switch SetupOperating Instructions Range Lockout Mode Selection Step Trigger Mode Operation SelectionSecurity Mode Selection Robotics Mode SelectionKeypad and Display Description Power-Down SaveKeypad and Display Operation Operation KeysTrigger Mode Select Key Trigger Mode SelectionDisplay Control Keys Acceleration Selection Security ModeFigure B.1 Wire Reel Loading READI-REELS, Spools or CoilsDrive Roll Pressure Setting Feeding Electrode and Brake AdjustmentGAS Guard Regulator Setting Procedure for Setting Angle of FeedplateMaking a Weld Display Prompt or Error Wire Reel ChangingWire Feed Overload Protection Explanation of Prompting and Error MessagesRoll DH Drive AccessoriesSolid & Cored Steel Electrode Driven K1758-L Input Cable Assem BLY K683-1 Dual Procedure SwitchK683-3 Dual Procedure Switch K1558-1 Remote Switch Interface ModuleK206, K289, and K309 GUN Adapters for 10 Series Wire Drive HeadsCoil Adapter Magnum 200/300/400 GunsGUN and Cable Assemblies K1634-1 Wire Reel Enclosure KITMaintenance MaintenanceHOW to USE Troubleshooting Guide TroubleshootingContact your local Lincoln Authorized Field Service Facility Contact your local Lincoln Authorized Field Service FacilityTroubleshooting Damaged encoder p.c. board Troubleshooting Electric Shock can kill Procedure for Replacing PC BoardsDiagrams Diagrams Diagrams Connection Diagrams Dimension Print Bench Model Dimension Print Boom Model Control Box STT-10 STT-10 Precaucion Warnung