Lincoln Electric IM586-B Trigger Mode Selection, Display Control Keys, Trigger Mode Select Key

Page 21

B-4

OPERATION

B-4

 

 

 

Trigger Mode Selection

 

Trigger Mode Select

key

COLD FEED

-

enables

operator

to

TRIGGER

2-STEP STD

choose mode of operation

4-STEP LOCK

shown by the indicator

SPOT

lights. Pressing key caus-

 

es

mode

lights

to

sequence (top to bottom) starting from the current indicated selection.

Top Light - Indicates gun trigger has been selected to perform the Cold Feed Forward function in exactly the same manner as Cold Feed Forward key (See Operation Keys - Cold Feed Keys) with the same memory stored adjustable speed setting, and “Cld” shown on the top display.

Second Light - indicates 2-step (standard) trigger mode.

1.Trigger closure energizes the solenoid valve, then the wire feeder and the power source after Preflow time.

2.Releasing the trigger turns off the wire feeder, then power source after burnback time and then the gas solenoid valve after Postflow time.

Third Light - indicates 4-step (lock) trigger mode. This mode may be selected to include or exclude weld current interlock. (See “4-Step Trigger Mode Operation Selection” in this section for 4 step Trigger Mode operation)

Bottom Light - indicates Spot Weld Mode, which will only light if a spot time is set (See “Display Control Keys” in this section). If set to 0.0 seconds, spot mode light selection will be skipped. Trigger closure energizes the gas solenoid valve, then wire feeder and the power source. The spot timer starts when current flows. The wire feeder and power source then solenoid valve are all turned off when the spot on timer times out even though the trigger is opened or is still closed. Preflow/Postflow and burnback timers are also functional in spot mode. (See “Display Control Keys” in this section).

Display Control Keys

CONTROL

Control Select key - enables operator to

 

 

choose Run-in WFS, burnback, spot or

 

gas timers, as indicated by the appro-

 

priate light. Pressing the key causes

 

lights to sequence (top to bottom, then

 

all off) starting from the current indicat-

 

ed selection.

When burnback spot, or gas timers are selected the current display shows the time setting in seconds, as indicated by “SEC” displayed on the speed display. The times are set using the top encoder knob.

When Run-in WFS is selected the WFS display shows the Run-in WFS setting in in/min. or m/min.

Top Light - indicates Run-in WFS is being displayed.

Speed encoder knob can adjust, Run in speed

 

RUN-IN

between minimum. Rated speed

 

WFS

and up to the Weld speed setting.

 

 

1

PREFLOW

Run-in speed can not be set above

 

 

weld speed setting. A Run-in

 

SPOT

speed setting of 100 IPM or less is

 

 

 

BURNBACK

recommended for optimum start-

 

ing. Factory setting is near

 

 

 

2 POSTFLOW

minimum rated speed.

If set below minimum rated speed “- -” will show on WFS display, indicated Run-In speed is set to match Weld speed setting.

When trigger is closed (and preflow time is over) the wire feeds at Run-In speed until the welding arc strikes, which causes the feed speed and volts to change to Weld settings.

If the arc does not strike within about 2 seconds, the Run-In speed automatically changes to Weld speed to permit “Hot” feeding at higher speed setting for load- ing wire.

Second Light - indicates preflow time is being dis- played, settable 0.0 to 2.5 seconds. (0.2 sec as shipped). This is the time the shielding gas flows before the wire feed and power source are activated.

Third Light - indicates spot time is being displayed, settable 0.0 to 199.9 seconds (0.0 sec as shipped).

Fourth Light - indicates burnback time is being dis- played, settable 0.00 to 0.25 seconds (0.0 sec as shipped). This is the time the arc power is delayed at the stop of the weld, and should be set to the lowest time required to prevent the wire sticking in the weld.

Bottom Light - indicates postflow time is being dis- played, settable 0.0 to 10.0 seconds (0.5 sec as shipped). This is the time the shielding gas flows after the wire feed and power source are deactivated.

Pressing Control Select Key again, or closing the gun trigger, shuts all control lights off, indicating current and Wire Feed Speed are again being displayed, and set by the appropriate encoder knob.

STT-10

Image 21
Contents IM586-B California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Diagrams Section F ViiP312 Series Installation General DescriptionSTT-10 Safety Precautions Mounting the 10 Series Wire Drive UnitRecommended Processes and Equipment Mounting Synergic 7F Wire Drive Unit Connecting Wire Drive Unit to Control BoxMounting the STT-10 Control Box K1565-2 Boom Model Control Speed Range Setting Wire Drive Speed Range SelectionSeries Wire Drive Ratio Selection Electrode RoutingProcedure to Install Drive Roll and Wire Guides Wire Feed Drive Roll KitsSynergic 7F 4-Roll Kits KP655 and KP656 Electric Shock can killGUN and Cable Assemblies with Standard Connection GUN Connections GeneralGUN and Cable Assemblies with FAST-MATE Connection Gmaw GunsWater Connections for Water Cooled Guns Synergic 7F Wire Drives K679Gun Cable Connection with Fast-Mate Connection Gmaw Shielding GasInput Cable STT-10 Control to Power Source Electrical InstallationDual Procedure Switch Options Optional Features InstallationBoom and Bench Conversions Materials Required for bench to boom conversionSTT-10 Control DIP Switch Setup OperationOperating Instructions Security Mode Selection Step Trigger Mode Operation SelectionRobotics Mode Selection Range Lockout Mode SelectionKeypad and Display Operation Power-Down SaveOperation Keys Keypad and Display DescriptionTrigger Mode Selection Trigger Mode Select KeyDisplay Control Keys Acceleration Selection Security ModeFigure B.1 Wire Reel Loading READI-REELS, Spools or CoilsDrive Roll Pressure Setting Feeding Electrode and Brake AdjustmentProcedure for Setting Angle of Feedplate GAS Guard Regulator SettingMaking a Weld Wire Feed Overload Protection Wire Reel ChangingExplanation of Prompting and Error Messages Display Prompt or ErrorAccessories Roll DH DriveSolid & Cored Steel Electrode Driven K683-3 Dual Procedure Switch K683-1 Dual Procedure SwitchK1558-1 Remote Switch Interface Module K1758-L Input Cable Assem BLYCoil Adapter GUN Adapters for 10 Series Wire Drive HeadsMagnum 200/300/400 Guns K206, K289, and K309GUN and Cable Assemblies K1634-1 Wire Reel Enclosure KITMaintenance MaintenanceHOW to USE Troubleshooting Guide TroubleshootingContact your local Lincoln Authorized Field Service Facility Contact your local Lincoln Authorized Field Service FacilityTroubleshooting Damaged encoder p.c. board Troubleshooting Electric Shock can kill Procedure for Replacing PC BoardsDiagrams Diagrams Diagrams Connection Diagrams Dimension Print Bench Model Dimension Print Boom Model Control Box STT-10 STT-10 Precaucion Warnung