OPERATION | ||
|
|
|
Trigger Mode Selection
| Trigger Mode Select | key | ||
COLD FEED | - | enables | operator | to |
TRIGGER | ||||
choose mode of operation | ||||
shown by the indicator | ||||
SPOT | lights. Pressing key caus- | |||
| es | mode | lights | to |
sequence (top to bottom) starting from the current indicated selection.
Top Light - Indicates gun trigger has been selected to perform the Cold Feed Forward function in exactly the same manner as Cold Feed Forward key (See Operation Keys - Cold Feed Keys) with the same memory stored adjustable speed setting, and “Cld” shown on the top display.
Second Light - indicates
1.Trigger closure energizes the solenoid valve, then the wire feeder and the power source after Preflow time.
2.Releasing the trigger turns off the wire feeder, then power source after burnback time and then the gas solenoid valve after Postflow time.
Third Light - indicates
Bottom Light - indicates Spot Weld Mode, which will only light if a spot time is set (See “Display Control Keys” in this section). If set to 0.0 seconds, spot mode light selection will be skipped. Trigger closure energizes the gas solenoid valve, then wire feeder and the power source. The spot timer starts when current flows. The wire feeder and power source then solenoid valve are all turned off when the spot on timer times out even though the trigger is opened or is still closed. Preflow/Postflow and burnback timers are also functional in spot mode. (See “Display Control Keys” in this section).
Display Control Keys
CONTROL | Control Select key - enables operator to |
| |
| choose |
| gas timers, as indicated by the appro- |
| priate light. Pressing the key causes |
| lights to sequence (top to bottom, then |
| all off) starting from the current indicat- |
| ed selection. |
When burnback spot, or gas timers are selected the current display shows the time setting in seconds, as indicated by “SEC” displayed on the speed display. The times are set using the top encoder knob.
When
Top Light - indicates | ||
Speed encoder knob can adjust, Run in speed | ||
| between minimum. Rated speed | |
| WFS | and up to the Weld speed setting. |
|
| |
1 | PREFLOW | |
|
| weld speed setting. A |
| SPOT | speed setting of 100 IPM or less is |
|
| |
| BURNBACK | recommended for optimum start- |
| ing. Factory setting is near | |
|
| |
| 2 POSTFLOW | minimum rated speed. |
If set below minimum rated speed “-
When trigger is closed (and preflow time is over) the wire feeds at
If the arc does not strike within about 2 seconds, the
Second Light - indicates preflow time is being dis- played, settable 0.0 to 2.5 seconds. (0.2 sec as shipped). This is the time the shielding gas flows before the wire feed and power source are activated.
Third Light - indicates spot time is being displayed, settable 0.0 to 199.9 seconds (0.0 sec as shipped).
Fourth Light - indicates burnback time is being dis- played, settable 0.00 to 0.25 seconds (0.0 sec as shipped). This is the time the arc power is delayed at the stop of the weld, and should be set to the lowest time required to prevent the wire sticking in the weld.
Bottom Light - indicates postflow time is being dis- played, settable 0.0 to 10.0 seconds (0.5 sec as shipped). This is the time the shielding gas flows after the wire feed and power source are deactivated.
Pressing Control Select Key again, or closing the gun trigger, shuts all control lights off, indicating current and Wire Feed Speed are again being displayed, and set by the appropriate encoder knob.