DUTY CYCLE

This air compressor pump is capable of running continuously. However, to prolong the life of your air compressor, it is recommended that a 50%-75% average duty cycle be maintained; that

is, the air compressor pump should not run more than 30-45 minutes in any given hour.

ASSEMBLY

Unpacking

Remove unit from carton and discard all packaging.

INSTALLATION

HOW TO SET UP YOUR UNIT

Location of the Air Compressor

Locate the air compressor in a clean, dry and well ventilated area.

The air compressor should be located at least 12" (30.5 cm) away from the wall or other obstructions that will interfere with the flow of air.

Place the air compressor on a flat level surface resting on the rub- ber bumpers and wheels

The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.

Grounding

Instructions

Risk of Electrical Shock. In the

event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded.

The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see following illustrations).

1.The cord set and plug with this unit contains a grounding pin. This plug MUST be used with a grounded outlet.

IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.

2.Make sure the outlet being used has the same configuration as the grounded plug. DO NOT USE AN ADAPTER. See illustration.

Plug

Grounded

Outlets

Grounding Pin

3.Inspect the plug and cord before each use. Do not use if there are signs of damage.

4.If these grounding instructions are not completely understood, or if in doubt as to whether the compres- sor is properly grounded, have the installation checked by a qualified electrician.

Risk of Electrical

Shock. IMPROPER

GROUNDING CAN RESULT IN

ELECTRICAL SHOCK.

10- ENG­

Image 10
Contents Air Compressor Table of Contents WarrantyImportant Safety Instructions Specification ChartSafety Guidelines Definitions Model No 919.167551Hazard Risk of explosion or fire What can happen How to prevent itWhat can happen How to prevent it Risk to Breathing AsphyxiationRisk of Bursting Attachments & accessories TiresRisk of Hot surfaces Risk from Flying Objects What can happen How to prevent itRisk from Moving Parts Risk of Falling Risk of Unsafe Operation What can happen How to prevent itRisk of Injury from Lifting Accessories AccessoriesRisk from noise What can happen How to prevent it GlossaryDuty Cycle AssemblyInstallation UnpackingVoltage and Circuit Protection Transporting When transporting the compressorExtension Cords LiftingOperation Description of OperationHow to Stop How to Use Your UnitAir Compressor Pump not shown Procedure Daily Weekly See tank Or after Each use Label MaintenanceHow to Start Customer ResponsibilitiesTo Drain Tank To Check Safety ValveAir Filter Be Performed by Trained Service Technician Service and AdjustmentsALL Maintenance and Repair Operations not Listed Must To Replace Check ValveTo Replace Regulator StorageOutlet Pressure Gauge Quick Connect Regulator Troubleshooting Problem Cause CorrectionOperation section Refer to Motor Overload Protection under Operation21­ Cuadro DE Especificaciones ContenidoGarantía Garantía Total DE CraftsmanSerias Lesiones menores o moderadas Definiciones DE Normas DE SeguridadInstrucciones Importantes DE Seguridad Serias PropiedadRiesgo Respiratorio asfixia Peligro¿Qué puede suceder? Cómo evitarlo Riesgo de explosión Elementos y accesoriosConsulte las Instrucciones de NeumáticosRiesgo de descarga eléctrica Conexión a tierra en InstalaciónRiesgo por piezas móviles Riesgo DE superficies calientesRiesgo DE Lesión POR Levantar Riesgo por ruidos ¿Qué puede suceder? Cómo evitarlo GlosarioAccesorios AccesoriosInstalación Ciclo DE ServicioEnsamblado DéballageTransporte Cables prolongadoresProtección del voltaje y del circuito Levantar la UnidadDescripción de operaciones OperaciónConozca su compresor de aire Válvula deCómo utilizar su unidad Antes de ponerlo en marchaResponsabilidades del cliente MantenimientoCómo verificar la válvula de seguridad Controlar el elemento del filtro de aire Cómo drenar el tanqueRiesgo de Explosión. El Para reemplazar la válvula de retención Servicio Y AjustesNota de Para reemplazar el regulador AlmacenajeRiesgo de Explosión. El agua Guía DE Diagnóstico DE Problemas Consulte Protector de sobre Carga del motor en la sección44- SP 45­ Page 47­ 1-800-4-MY-HOME LE-FOYER MC Sears Parts & Repair Service Center CanadaNo matter who made it, no matter who sold it SU-HOGAR