Craftsman 919.167551 Hazard, Risk of explosion or fire What can happen How to prevent it

Page 4

HAZARD

Risk of explosion or fire

 

 

 

What can happen

How to prevent it

 

• It is normal for electrical contacts

• Always operate the compressor

 

within the motor and pressure

in a well ventilated area free of

 

switch to spark.

combustible materials, gasoline, or

 

 

 

 

 

solvent vapors.

 

 

 

 

 

 

 

• If electrical sparks from compressor

• If spraying flammable materials,

 

come into contact with flammable

locate compressor at least 20'

 

vapors, they may ignite, causing fire

(6.1 m) away from spray area. An

 

or explosion.

additional length of air hose may be

 

 

 

 

 

required.

 

 

 

 

 

• Store flammable materials in

 

 

 

 

 

a secure location away from

 

 

 

 

 

compressor.

 

• Restricting any of the compressor

• Never place objects against or on

 

ventilation openings will cause

top of compressor.

 

serious overheating and could

• Operate compressor in an open area

 

cause fire.

at least 12" (30.5 cm) away from

 

 

 

 

 

any wall or obstruction that would

 

 

 

 

 

restrict the flow of fresh air to the

 

 

 

 

 

ventilation openings.

 

 

 

 

 

• Operate compressor in a clean, dry

 

 

 

 

 

well ventilated area. Do not operate

 

 

 

 

 

unit in any confined area. Store

 

 

 

 

 

indoors.

 

• Unattended operation of this

• Always remain in attendance with

 

product could result in personal

the product when it is operating.

 

injury or property damage. To

• Always turn off and unplug unit

 

reduce the risk of fire, do not

when not in use.

 

allow the compressor to operate

 

 

unattended.

 

 

 

 

 

HAZARD

 

 

 

 

RISK TO BREATHING (Asphyxiation)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

What can happen

How to prevent it

 

• The compressed air directly from

• Never use air obtained directly

 

your compressor is not safe for

from the compressor to supply

 

breathing. The air stream may

air for human consumption. The

 

contain carbon monoxide, toxic

compressor is not equipped with

 

vapors, or solid particles from

suitable filters and in-line safety

 

the air tank. Breathing these

equipment for human consumption.

 

contaminants can cause serious

 

 

injury or death.

 

4- ENG­

Image 4
Contents Air Compressor Table of Contents WarrantySpecification Chart Safety Guidelines DefinitionsImportant Safety Instructions Model No 919.167551Risk of explosion or fire What can happen How to prevent it What can happen How to prevent itHazard Risk to Breathing AsphyxiationRisk of Bursting Attachments & accessories TiresRisk of Hot surfaces Risk from Flying Objects What can happen How to prevent itRisk from Moving Parts Risk of Falling Risk of Unsafe Operation What can happen How to prevent itRisk of Injury from Lifting Accessories Risk from noise What can happen How to prevent itAccessories GlossaryAssembly InstallationDuty Cycle UnpackingTransporting When transporting the compressor Extension CordsVoltage and Circuit Protection LiftingOperation Description of OperationHow to Stop How to Use Your UnitAir Compressor Pump not shown Maintenance How to StartProcedure Daily Weekly See tank Or after Each use Label Customer ResponsibilitiesTo Drain Tank To Check Safety ValveAir Filter Service and Adjustments ALL Maintenance and Repair Operations not Listed MustBe Performed by Trained Service Technician To Replace Check ValveTo Replace Regulator StorageOutlet Pressure Gauge Quick Connect Regulator Troubleshooting Problem Cause CorrectionOperation section Refer to Motor Overload Protection under Operation21­ Contenido GarantíaCuadro DE Especificaciones Garantía Total DE CraftsmanDefiniciones DE Normas DE Seguridad Instrucciones Importantes DE SeguridadSerias Lesiones menores o moderadas Serias PropiedadRiesgo Respiratorio asfixia Peligro¿Qué puede suceder? Cómo evitarlo Riesgo de explosión Elementos y accesoriosNeumáticos Riesgo de descarga eléctricaConsulte las Instrucciones de Conexión a tierra en InstalaciónRiesgo por piezas móviles Riesgo DE superficies calientesRiesgo DE Lesión POR Levantar Glosario AccesoriosRiesgo por ruidos ¿Qué puede suceder? Cómo evitarlo AccesoriosCiclo DE Servicio EnsambladoInstalación DéballageCables prolongadores Protección del voltaje y del circuitoTransporte Levantar la UnidadOperación Conozca su compresor de aireDescripción de operaciones Válvula deCómo utilizar su unidad Antes de ponerlo en marchaResponsabilidades del cliente MantenimientoCómo verificar la válvula de seguridad Controlar el elemento del filtro de aire Cómo drenar el tanqueRiesgo de Explosión. El Para reemplazar la válvula de retención Servicio Y AjustesNota de Para reemplazar el regulador AlmacenajeRiesgo de Explosión. El agua Guía DE Diagnóstico DE Problemas Consulte Protector de sobre Carga del motor en la sección44- SP 45­ Page 47­ 1-800-4-MY-HOME Sears Parts & Repair Service Center Canada No matter who made it, no matter who sold itLE-FOYER MC SU-HOGAR