Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.

Tank Pressure Gauge

Pressure

Switch

Outlet Pressure

Gauge

Auto(I)/Off(O) Switch

Quick Connect

Regulator

Description of Operation

Become familiar with these controls before operating the unit.

Auto (I)/Off (O) Switch: Turn this switch "Auto (I)" to provide automatic power to the pressure switch and "Off (O)" to remove power at the end of each use.

Pressure Switch: The pressure switch automatically starts the motor when the air tank pressure drops below the factory set "cut-in" pressure. It stops the motor when the air tank pressure reaches the factory set "cut-out" pres- sure.

Safety Valve: If the pressure switch does not shut off the air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its fac- tory set pressure (slightly higher than the pressure switch "cut-out" setting). Outlet Pressure Gauge: The outlet pressure gauge indicates the air pres- sure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure. Tank Pressure Gauge: The tank pres- sure gauge indicates the reserve air pressure in the tank.

Regulator: Controls the air pressure shown on the outlet pressure gauge. Pull the knob out and turn clockwise to increase pressure and counterclock- wise to decrease pressure. When the desired pressure is reached push knob in to lock in place.

Universal Quick-Connect Body: The universal quick-connect body accepts the three most popular styles of quick- connect plugs: Industrial, automotive (Tru-flate), and ARO. One hand push- to-connect operation makes connec- tions simple and easy.

Drain Valve:

 

 

 

 

The drain valve is

 

 

located at the

 

 

base of the air

 

Drain

tank and is used

 

Valve

to drain conden-

 

 

 

 

sation at the end of each use.

 

Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.

12- ENG­

Image 12
Contents Air Compressor Table of Contents WarrantySpecification Chart Safety Guidelines DefinitionsImportant Safety Instructions Model No 919.167551Risk of explosion or fire What can happen How to prevent it What can happen How to prevent itHazard Risk to Breathing AsphyxiationRisk of Bursting Attachments & accessories TiresRisk from Flying Objects What can happen How to prevent it Risk of Hot surfacesRisk from Moving Parts Risk of Unsafe Operation What can happen How to prevent it Risk of FallingRisk of Injury from Lifting Accessories Risk from noise What can happen How to prevent itAccessories GlossaryAssembly InstallationDuty Cycle UnpackingTransporting When transporting the compressor Extension CordsVoltage and Circuit Protection LiftingOperation Description of OperationHow to Use Your Unit How to StopAir Compressor Pump not shown Maintenance How to StartProcedure Daily Weekly See tank Or after Each use Label Customer ResponsibilitiesTo Check Safety Valve To Drain TankAir Filter Service and Adjustments ALL Maintenance and Repair Operations not Listed MustBe Performed by Trained Service Technician To Replace Check ValveStorage To Replace RegulatorOutlet Pressure Gauge Quick Connect Regulator Troubleshooting Problem Cause CorrectionOperation section Refer to Motor Overload Protection under Operation21­ Contenido GarantíaCuadro DE Especificaciones Garantía Total DE CraftsmanDefiniciones DE Normas DE Seguridad Instrucciones Importantes DE SeguridadSerias Lesiones menores o moderadas Serias PropiedadPeligro Riesgo Respiratorio asfixia¿Qué puede suceder? Cómo evitarlo Riesgo de explosión Elementos y accesoriosNeumáticos Riesgo de descarga eléctricaConsulte las Instrucciones de Conexión a tierra en InstalaciónRiesgo por piezas móviles Riesgo DE superficies calientesRiesgo DE Lesión POR Levantar Glosario AccesoriosRiesgo por ruidos ¿Qué puede suceder? Cómo evitarlo AccesoriosCiclo DE Servicio EnsambladoInstalación DéballageCables prolongadores Protección del voltaje y del circuitoTransporte Levantar la UnidadOperación Conozca su compresor de aireDescripción de operaciones Válvula deCómo utilizar su unidad Antes de ponerlo en marchaMantenimiento Responsabilidades del clienteCómo verificar la válvula de seguridad Cómo drenar el tanque Controlar el elemento del filtro de aireRiesgo de Explosión. El Servicio Y Ajustes Para reemplazar la válvula de retenciónNota de Almacenaje Para reemplazar el reguladorRiesgo de Explosión. El agua Guía DE Diagnóstico DE Problemas Consulte Protector de sobre Carga del motor en la sección44- SP 45­ Page 47­ 1-800-4-MY-HOME Sears Parts & Repair Service Center Canada No matter who made it, no matter who sold itLE-FOYER MC SU-HOGAR