Craftsman 919.167551 Storage, To Replace Regulator, Outlet Pressure Gauge Quick Connect Regulator

Page 17

To Replace Regulator

1.Release all air pressure from air tank. See To Drain Tank in the Maintenance section.

2.Unplug compressor.

3.Remove shrouds.

4.Remove the outlet pressure gauge and quick connect from the regulator.

Outlet

Pressure

Gauge

Quick

Connect

Regulator

5.Remove the regulator.

6.Reapply pipe sealant to outlet pressure gauge and quick connect.

7.Assemble quick connect to new regulator and tighten.

Regulator

Nipple Arrow

Quick

 

Connect

8.Apply pipe sealant tape to the nipple.

9.Assemble the regulator. NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of air flow.

10.Use the hex on quick connect to tightening regulator. Orient as shown.

11.Assemble outlet pressure gauge. Orient outlet pressure gauge to read correctly.

12.Replace shrouds.

STORAGE

Before you store the air compressor, make sure you do the following:

1.Review the Maintenance section on the preceding pages and per- form scheduled maintenance as necessary.

2.Drain water from air tank. See To Drain Tank under Maintenance.

Water will condense in the

air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

3.Protect the electrical cord and air hose from damage (such as being stepped on or run over).

Wind them loosely around the compressor handle.

4.Store the air compressor in a clean and dry location.

17-­ ENG

Image 17
Contents Air Compressor Warranty Table of ContentsSafety Guidelines Definitions Specification ChartImportant Safety Instructions Model No 919.167551What can happen How to prevent it Risk of explosion or fire What can happen How to prevent itHazard Risk to Breathing AsphyxiationRisk of Bursting Tires Attachments & accessoriesRisk from Moving Parts Risk from Flying Objects What can happen How to prevent itRisk of Hot surfaces Risk of Injury from Lifting Risk of Unsafe Operation What can happen How to prevent itRisk of Falling Risk from noise What can happen How to prevent it AccessoriesAccessories GlossaryInstallation AssemblyDuty Cycle UnpackingExtension Cords Transporting When transporting the compressorVoltage and Circuit Protection LiftingDescription of Operation OperationAir Compressor Pump not shown How to Use Your UnitHow to Stop How to Start MaintenanceProcedure Daily Weekly See tank Or after Each use Label Customer ResponsibilitiesAir Filter To Check Safety ValveTo Drain Tank ALL Maintenance and Repair Operations not Listed Must Service and AdjustmentsBe Performed by Trained Service Technician To Replace Check ValveOutlet Pressure Gauge Quick Connect Regulator StorageTo Replace Regulator Problem Cause Correction TroubleshootingOperation section Protection under Operation Refer to Motor Overload21­ Garantía ContenidoCuadro DE Especificaciones Garantía Total DE CraftsmanInstrucciones Importantes DE Seguridad Definiciones DE Normas DE SeguridadSerias Lesiones menores o moderadas Serias Propiedad¿Qué puede suceder? Cómo evitarlo PeligroRiesgo Respiratorio asfixia Elementos y accesorios Riesgo de explosiónRiesgo de descarga eléctrica NeumáticosConsulte las Instrucciones de Conexión a tierra en InstalaciónRiesgo DE superficies calientes Riesgo por piezas móvilesRiesgo DE Lesión POR Levantar Accesorios GlosarioRiesgo por ruidos ¿Qué puede suceder? Cómo evitarlo AccesoriosEnsamblado Ciclo DE ServicioInstalación DéballageProtección del voltaje y del circuito Cables prolongadoresTransporte Levantar la UnidadConozca su compresor de aire OperaciónDescripción de operaciones Válvula deAntes de ponerlo en marcha Cómo utilizar su unidadCómo verificar la válvula de seguridad MantenimientoResponsabilidades del cliente Riesgo de Explosión. El Cómo drenar el tanqueControlar el elemento del filtro de aire Nota de Servicio Y AjustesPara reemplazar la válvula de retención Riesgo de Explosión. El agua AlmacenajePara reemplazar el regulador Guía DE Diagnóstico DE Problemas Carga del motor en la sección Consulte Protector de sobre44- SP 45­ Page 47­ 1-800-4-MY-HOME No matter who made it, no matter who sold it Sears Parts & Repair Service Center CanadaLE-FOYER MC SU-HOGAR