Operating Instructions and Parts Manual
Installation (Continued)
Wiring
1.Local electrical wiring codes differ from area to area. Source wiring, plug and protector must be rated for at least the amperage and voltage indicated on motor nameplate, and meet all electrical codes for this minimum.
2.Use a slow blow fuse or a circuit breaker.
Overheating, short circuiting and fire damage will result from inadequate wiring, etc.
NOTE: 120 volt, 15 amp units can be operated on a 120 volt circuit under the following conditions:
a.No other electrical appliances or lights are connected to the same branch circuit.
b.Voltage supply is normal.
c.Circuit is equipped with a 15 amp circuit breaker or a 15 amp slow blow fuse.
3.If these conditions cannot be met or if nuisance tripping of current protection device occurs, it may be necessary to operate compressor from a 120 volt, 20 amp circuit.
Operation
Moisture in compressed air
Moisture in compressed air will form into droplets as it comes from an air compressor pump. When humidity is high or when a compressor is in continuous use for an extended period of time, this moisture will collect in the tank. When using a paint spray or sandblast gun, this water will be carried from the tank through the hose, and out of the gun as droplets mixed with the spray material.
IMPORTANT: This condensation will cause water spots in a paint job, especially when spraying other than water based paints. If sandblasting, it will cause the sand to cake and clog the gun, rendering it ineffective. A filter in the air line (MP3105), located as near to the gun as possible, will help eliminate this moisture.
This compressor can be used for general inflation as well as intermittent duty air tool usage. For inflation purposes, this compressor utilizes a new technology called Rapid Inflation Technology (RIT).
IMPORTANT: Make sure the Wheel Lock/Foot Brake is engaged before operating the unit (See Figure 11).
Lubrication
This is an oilless product and does not require lubrication to operate.
Outlet (Tool) | Storage Trays |
Pressure Gauge |
|
| Tank |
| Pressure |
| Gauge |
| |
regulator |
|
ASME |
|
Safety Valve |
|
Figure 13