Operating Instructions and Parts Manual
Maintenance (Continued)
IMPORTANT: Unit should be located as far from spraying area as hose will allow to prevent
Air FIlter
Check air filter to be sure it is clean. To service the air filter, tip the unit back, resting the wheels and handle on the floor (See Figure 20). Remove the filter housing cover. Remove filter and blow off dirt. Replace air filter if it can not be cleaned. Place filter back in the housing base. Replace cover.
Lubrication
This is an oilless type compressor requiring no lubrication.
Thermal Overload Protector
This compressor is equipped with an automatic reset thermal overload protector which will shut
off motor if it becomes overheated.
If thermal overload protector shuts motor OFF frequently look for the following causes:
1.Low voltage
2.Lack of proper ventilation
Air Filter |
Figure 20 - Air Filter
If the thermal overload protector is actuated, the motor must be allowed to cool down before
startup is possible. The motor will automatically restart without warning if left plugged into electrical outlet and unit is turned on.
Torque Requirements
Piston Bolt . . . . . . . . . . . 350 - 450 in. Ibs. Head Bolts . . . . . . . . . . . 90 - 120 in. Ibs.
Technical Service
For information regarding the operation or repair of this product, please call
16www.chpower.com