Tripp Lite APSX6048VR owner manual Specifications, Limited Warranty

Page 11

Specifications

 

MODEL NUMBER:

APSX6048VR

 

AC Input Connection:

Hardwire

 

 

 

 

INVERTER

 

 

 

 

The Inverter/Charger includes a Battery Charge Conserver (Load Sense) Control which saves battery power by allowing users to set the minimum load level at which the unit’s inverter turns on. Users can significantly reduce the No Load DC Input Current to a very low amp level with the use of this control.

 

Output Volts:

208/230* VAC, ± 5%

 

Output Frequency (Nominal):

50*/60 Hz, ± 0.5%

 

Efficiency:

85% to 94%, depending on load and temperature

 

Continuous Power (@ 20°C):

6000 W

 

OverPower™ Peak Surge Power:**

9000 W

 

DoubleBoost™ Peak Surge Power:***

12000 W

 

DC Input Volts (Nominal):

48 VDC

 

DC Input Voltage Range:

42-60 VDC

 

Minimum DC Fuse Rating:

250 A

 

DC Input Current @ Nominal V DC

 

 

Full Load:

138 A

 

 

 

 

BATTERY CHARGER

 

 

Input Volts (Nominal):

208/230* VAC

 

Charging Capacity DC:

23*/90 A

 

Acceptance Volts VDC:

57.6*/56.4 V

 

Selectable (Wet*/Gel)

 

 

Float Volts VDC (Wet/Gel):

54*/54.4 V

 

Charger Only Input Current AC (Maximum):

25 A

 

 

 

 

LINE VAC OPERATION

 

 

Minimum Input Volts (Transfer to Battery):

165*/175VAC (208V) or 170*/180VAC (230V)

 

 

 

 

Maximum Input Volts (Transfer to Battery):

235*/245VAC (208V) or 260*/270VAC (230V)

 

 

 

 

Input Frequency (Nominal):

50*/60 Hz, ±10%

 

 

 

 

Total Input AC Current

 

 

(Continuous, Charger at Maximum):

30 A

 

Maximum Bypass AC

 

 

Current (Continuous):

30 A

*Factory setting. ** The Tripp Lite APSX6048VR Inverter/Charger delivers up to 150% of its nameplate-rated wattage for up to 60 seconds under ideal battery and temperature conditions. For best results, utilize OverPower for as short a duration as possible, ensure that battery bank and cabling are able to provide full nominal DC voltage under load, and allow the inverter/charger to cool completely before and after OverPower utilization. *** DoubleBoost duration (up to 10 seconds). Actual duration depends on battery age, battery charge level and ambient temperature.

Minimum Recommended Cable Sizing

Use in conjunction with DC wiring connection instructions in the Battery Connection section.

NOTE: Acceptable power is directly related to cable length (i.e. - the shorter the cable, the better the performance). Cable length is the sum of the positive cable length and the negative cable length.

 

Inverter/Charger DC Volt: 48

 

 

 

 

 

 

 

 

Wire Gauge

 

 

 

 

 

 

Watts

4

2

0

00

2000

23 ft (7.0 m)

36 ft (11.0 m)

50 ft (15.2 m)

75 ft (22.9 m)

3000

15 ft (4.6 m)

24 ft (7.3 m)

40 ft (12.2 m)

50 ft (15.2 m)

4000

11 ft (3.4 m)

18 ft (5.5 m)

30 ft (9.1 m)

37 ft (11.3 m)

5000

9 ft (2.7 m)

14 ft (4.3 m)

24 ft (7.3 m)

30 ft (9.1 m)

6000

7 ft (2.1 m)

12 ft (3.7 m)

20 ft (6.1 m)

25 ft (7.6 m)

Note on Labeling

Two symbols are used on the APS labels.

V~: AC Voltage

 

: DC Voltage

 

Limited Warranty

Tripp Lite warrants its Inverter/Chargers to be free from defects in materials and workmanship for a period of one year (except for outside of U.S.A., Canada and Mexico—120 days) from the date of retail purchase by end user.

Tripp Lite’s obligation under this warranty is limited to repairing or replacing (at its sole option) any such defective products. To obtain service under this warranty you must obtain a Returned Material Authorization (RMA) number from Tripp Lite or an authorized Tripp Lite service center. Products must be returned to Tripp Lite or an authorized Tripp Lite service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. This warranty does not apply to equipment which has been damaged by accident, negligence or misapplication or has been altered or modified in any way, including opening of the unit’s casing for any reason. This warranty applies only to the original purchaser who must have properly registered the product within 10 days of retail purchase.

EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser.

EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, Tripp Lite is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise.

Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.

Regulatory Compliance Identification Numbers

For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique series number. The series number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to the series number. The series number should not be confused with the marking name or model number of the product.

11

Image 11
Contents APSX6048VR Pure Sine Wave DC-to-AC Inverter/Charger ContentsEquipment Connection Warnings Important Safety InstructionsBattery Connection Warnings Location WarningsFeature Identification Operation Switch ModesIndicator Lights Set Configuration DIP Switches ConfigurationSwitch #4 Set for 230 VAC Operation #4 Down Example Battery SelectionSelect Battery Type Match Battery Amp-Hour Capacity to Your Application Non-Vehicular or Vehicular Applications Battery ConnectionAC Input/Output Connection ServiceMaintenance Symptom Problems Corrections TroubleshootingLimited Warranty SpecificationsMejor Para Sus Baterías ContenidoConfiable Energía de Respaldo de Emergencia Mejor para Su EquipoAdvertencias para la Conexión del Equipo Instrucciones de Seguridad ImportantesAdvertencias para la Ubicación de su Equipo Advertencias para la Conexión de la BateríaIdentificación de Características Luces Indicadoras OperaciónModos del Interruptor Ajuste los Interruptores de Configuración DIP ConfiguraciónInterruptor # 4 Ajustado para operar a 230 VAC # 4 Abajo Configuración continuaciónEjemplo Selección de la BateríaSeleccione el Tipo de Batería Aplicaciones No Vehiculares o Vehiculares Conexión de la BateríaMantenimiento Conexión de Entrada/Salida CAServicio Sintoma Problemas Correcciones Solución de ProblemasGarantía Limitada EspecificacionesMeilleur pour vos batteries Table des matièresAlimentation de secours fiable Meilleur pour votre équipementMises en garde concernant les connexions de léquipement Mises en garde concernant lemplacement de londuleurImportantes consignes de sécurité Mises en garde concernant la connexion de batterieCaractéristiques Témoins lumineux FonctionnementModes Cycle Bas réglage d’usine Configuration des commutateurs DIPCommutateur 4 sur opération 230 V CA vers le bas Configuration suiteExemple Choix de batterieChoisir le type de batterie Applications non véhiculaires et véhiculaires Connexion de batterieEntretien Connexion entrée/sortie CASymptôme Problèmes Corrections DépannageGarantie limitée SpécificationsЗарядка СодержаниеВходВыход Инвертирование Переменного токаХраните ЭТУ Инструкцию Важные указания по технике безопасностиОписание функций Красная Лампа Нагрузка ЭксплуатацияЗеленая лампа Линия если переключатель Желтая лампа Инвертор этаНастройка Подключение удаленного управления Опциональное Напряжение Положение джампераВыбор типа батарей Необходимый Тип батарей Положение джампераШАГ 3 Определите потребную емкость батарей Выбор батарейШАГ 2 Определите потребную силу постоянного тока батарей ИЗУ Подключение батарейОбслуживание Подключение входа и нагрузки переменного токаПризнак Неисправность Способ Устранения Поиск и устранение неисправностейРекомендованные минимальные размеры кабелей † Технические характеристикиОграниченная гарантия