Tripp Lite APSX6048VR owner manual Operation, Switch Modes, Indicator Lights

Page 4
(Position ø)
Position —
Position =

Operation

Switch Modes

After configuring, mounting and connecting your Inverter/Charger, you are able to operate it by switching between the following operating modes as appropriate to your situation:

AUTO/REMOTE: Switch to this mode when you need constant, uninterrupted AC power for connected appliances and equipment. The Inverter/Charger will continue to supply AC power to connected equipment

and to charge your connected batteries while utility- or generator-supplied AC power is present. Since the

inverter is ON (but in Standby) in this mode, it will automatically switch to your battery system to supply AC power to connected equipment in the absence of a utility/generator source or in over/under voltage situations. “AUTO/REMOTE” also enables an optional remote control module (Tripp Lite model APSRM4, sold separately) to function when connected to the unit.

LOAD Red Indicator: This red light will

 

 

 

 

 

OPERATION

 

ILLUMINATE CONTINUOUSLY whenever the

 

 

LINE

 

 

 

 

INV

 

inverter is functioning and the power demanded by

 

 

LOAD

 

 

 

 

 

 

 

connected appliances and equipment exceeds 100%

 

 

 

 

 

of load capacity. The light will FLASH to alert you

 

 

 

 

 

when the inverter shuts down due to a severe

 

 

 

 

 

overload or overheating. If this happens, turn the operating mode switch “OFF”; remove the overload and let the unit cool. You may then turn the operating mode switch to either “AUTO/REMOTE” or “CHARGE ONLY” after it has adequately cooled. This light will be off when AC power is supplying the load.

BATTERY Indicator Lights: These three lights will illuminate in several sequences to show the approximate charge level of your connected battery bank and alert you to two fault conditions:

Approximate Battery Charge Level*

CHARGE ONLY: Switch to this mode when you are not using connected appliances and equipment in order to conserve battery power by disabling the inverter. The Inverter/Charger will continue to supply AC power to connected equipment and charge connected batteries while utility- or generator-

supplied AC power is present. However, since the inverter is OFF in this mode, it WILL NOT supply AC power to connected equipment in the absence of a utility/generator source or in over/under voltage situations.

OFF: Switch to this mode to shut down the Inverter/Charger completely, preventing the inverter from drawing power from the batteries, and preventing utilityAC from passing through to connected equipment

 

 

Indicator Illuminated

Battery Capacity

 

 

 

(Charging/Discharging)

 

 

 

Green

91%–Full

1

 

 

 

Green & Yellow

81%–90%

2

 

 

 

Yellow

61%–80%

3

 

 

 

Yellow & Red

41%–60%

4

 

 

 

Red

21%–40%

5

 

6

 

All three lights off

1%–20%

 

 

Flashing red

0% (Inverter

7

 

 

 

 

shutdown)

*Charge levels listed are approximate. Actual conditions vary depending on battery condition and load.

1

2

3

4

5

6

7

or charging the batteries. Use this switch to automatically reset the unit if it shuts down due to overload or overheating. First remove the excessive load or allow the unit to sufficiently cool (applicable to your situation). Switch to “OFF”, then back to “AUTO/REMOTE” or “CHARGE ONLY” as desired. If unit fails to reset, remove more load or allow unit to cool further and retry. Use an optional remote control module (Tripp Lite model APSRM4, sold separately) to reset unit due to overload only.

Indicator Lights

Your Inverter/Charger (as well as an optional Tripp Lite Remote Control Module, sold separately) is equipped with a simple, intuitive, user-friendly set of indicator lights. These easily-remembered “traffic light” signals will allow you, shortly after first use, to tell at a glance the charge condition of your batteries, as well as ascertain operating details and fault conditions.

LINE Green Indicator: If the operating mode

 

OPERATION

 

switch is set to “AUTO/REMOTE,” this light will

 

 

LINE

 

 

 

 

INV

 

ILLUMINATE CONTINUOUSLY when your

 

 

LOAD

 

 

 

 

 

 

 

connected equipment is receiving continuous AC

 

 

 

 

 

power supplied from a utility/generator source.

 

 

 

 

 

If the operating mode switch is set to “CHARGE ONLY,” this light will FLASH to alert you that the unit’s inverter is OFF and will NOT supply AC power in the absence of a utility/generator source or in over/under voltage situations.

INV (Inverting) Yellow Indicator: This light will

 

 

 

 

 

OPERATION

 

ILLUMINATE CONTINUOUSLY whenever connected

 

 

INV

 

 

 

 

LINE

 

 

equipment is receiving battery-supplied, inverted AC

 

 

 

 

 

 

LOAD

 

 

 

 

 

 

 

power (in the absence of a utility/generator source or

 

 

 

 

 

in over/under voltage situations). This light will be off

 

 

 

 

 

when AC power is supplying the load. This light will

 

 

 

 

 

 

 

 

 

 

FLASH to alert you if the load is less than the Battery Charge Conserver (Load Sense) setting.

Fault Condition

 

Indicator Illuminated

Fault Condition

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All three lights

Excessive discharge

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

flash slowly*

(Inverter shutdown)

 

 

 

 

 

 

 

2

All three lights

Overcharge (Charger

1

 

 

2

 

 

flash quickly**

shutdown)

 

 

 

 

 

*Approximately ½ second on, ½ second off. See Troubleshooting section. ** Approximately ¼ second on, ¼ second off. May also indicate a battery charger fault exists. See Troubleshooting section.

Resetting Your Inverter/Charger to Restore AC Power

Your Inverter/Charger may cease supplying AC power or DC charging power in order to protect itself from overload or to protect your electrical system. To restore normal functioning:

Overload Reset: Switch operating mode switch to “OFF” and

remove some of the connected electrical load (ie: turn off some of the AC devices drawing power which may have caused the overload of the unit). Wait one minute, then switch operating mode switch back to either “AUTO/REMOTE” or “CHARGE ONLY.”

4

Image 4
Contents Contents APSX6048VR Pure Sine Wave DC-to-AC Inverter/ChargerImportant Safety Instructions Battery Connection WarningsLocation Warnings Equipment Connection WarningsFeature Identification Indicator Lights Switch ModesOperation Configuration Set Configuration DIP SwitchesSwitch #4 Set for 230 VAC Operation #4 Down Battery Selection Select Battery TypeMatch Battery Amp-Hour Capacity to Your Application ExampleBattery Connection Non-Vehicular or Vehicular ApplicationsMaintenance ServiceAC Input/Output Connection Troubleshooting Symptom Problems CorrectionsSpecifications Limited WarrantyContenido Confiable Energía de Respaldo de EmergenciaMejor para Su Equipo Mejor Para Sus BateríasInstrucciones de Seguridad Importantes Advertencias para la Ubicación de su EquipoAdvertencias para la Conexión de la Batería Advertencias para la Conexión del EquipoIdentificación de Características Modos del Interruptor OperaciónLuces Indicadoras Configuración Ajuste los Interruptores de Configuración DIPConfiguración continuación Interruptor # 4 Ajustado para operar a 230 VAC # 4 AbajoSeleccione el Tipo de Batería Selección de la BateríaEjemplo Conexión de la Batería Aplicaciones No Vehiculares o VehicularesServicio Conexión de Entrada/Salida CAMantenimiento Solución de Problemas Sintoma Problemas CorreccionesEspecificaciones Garantía LimitadaTable des matières Alimentation de secours fiableMeilleur pour votre équipement Meilleur pour vos batteriesMises en garde concernant lemplacement de londuleur Importantes consignes de sécuritéMises en garde concernant la connexion de batterie Mises en garde concernant les connexions de léquipementCaractéristiques Modes FonctionnementTémoins lumineux Configuration des commutateurs DIP Cycle Bas réglage d’usineConfiguration suite Commutateur 4 sur opération 230 V CA vers le basChoisir le type de batterie Choix de batterieExemple Connexion de batterie Applications non véhiculaires et véhiculairesConnexion entrée/sortie CA EntretienDépannage Symptôme Problèmes CorrectionsSpécifications Garantie limitéeСодержание ВходВыход ИнвертированиеПеременного тока ЗарядкаВажные указания по технике безопасности Храните ЭТУ ИнструкциюОписание функций Эксплуатация Зеленая лампа Линия если переключательЖелтая лампа Инвертор эта Красная Лампа НагрузкаНастройка Напряжение Положение джампера Выбор типа батарей НеобходимыйТип батарей Положение джампера Подключение удаленного управления ОпциональноеШАГ 2 Определите потребную силу постоянного тока батарей Выбор батарейШАГ 3 Определите потребную емкость батарей Подключение батарей ИЗУПодключение входа и нагрузки переменного тока ОбслуживаниеПоиск и устранение неисправностей Признак Неисправность Способ УстраненияОграниченная гарантия Технические характеристикиРекомендованные минимальные размеры кабелей †
Related manuals
Manual 48 pages 42.2 Kb

APSX6048VR specifications

The Tripp Lite APSX6048VR is a leading-edge power inverter designed to meet the diverse needs of users requiring reliable and efficient backup power solutions. With a robust AC output, this 6000-watt inverter provides the capability to power multiple devices and systems simultaneously, making it ideal for both residential and commercial use. Its high power capacity allows it to handle heavy loads, making it suitable for essential appliances, tools, and equipment.

One of the standout features of the APSX6048VR is its advanced pure sine wave output. Unlike modified sine wave inverters, pure sine wave inverters deliver a smooth and consistent power supply that is compatible with sensitive electronics. This ensures safe and efficient operation for devices such as computers, medical equipment, and audio/visual systems, preventing damage and prolonging their lifespan.

The inverter also includes an impressive voltage output range of 48V, which optimizes performance and maximizes efficiency. This makes it an excellent choice for solar and battery backup systems, allowing for seamless integration with renewable energy setups. The APSX6048VR supports various charging input sources, making it versatile for different installations, whether on-grid or off-grid.

Another notable characteristic of this inverter is its built-in automatic transfer switch (ATS). This feature ensures a quick transition from mains power to inverter power in the event of a power failure, providing uninterrupted power to critical loads. Additionally, the Tripp Lite APSX6048VR features multiple safety mechanisms, including over-voltage protection, under-voltage protection, and short-circuit protection, guaranteeing safe operation under varying conditions.

The inverter is designed for easy installation and user-friendly operation. It comes equipped with an LCD display that provides vital system information such as input/output voltage, load capacity, and battery status. This real-time feedback allows users to monitor their power usage effectively.

With durable construction and a compact design, the Tripp Lite APSX6048VR is both portable and durable, making it a reliable choice for temporary setups or permanent installations. It’s an ideal power solution for anyone seeking a reliable inverter that combines high performance with advanced technology, ensuring that devices remain powered in any situation.