SECTION 3: CIRCUIT REQUIREMENTS
3-Phase Power
Serious personal injury could occur if you allow power to the machine before complet- ing the setup process. DO NOT allow power to the machine until instructed to do so.
Amperage Draw
The Model G0504 features a 220/440V motor that is prewired for 220V and draws the following amps under maximum load:
Motor Draw at 220V | 62.2 | Amps |
Motor Draw at 440V | 31.1 | Amps |
Circuit Requirements
We recommend connecting your machine to a dedicated and grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an existing circuit with one of higher amperage without consulting a quali- fied electrician to ensure compliance with wir- ing codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared circuit, consult a qualified electrician.
220V Circuit | 80 Amps |
440V Circuit | 40 Amps |
A fire may occur if your particular electrical configuration does not comply with local and state codes. The best way to ensure compli- ance is to check with your local municipality or a qualified electrician.
Connection Type
This machine is intended to be installed in a
Figure 1. A power disconnect is preferable to
high current plugs and receptacles.
Figure 2. Power connection points inside the
electrical box.
G0504 16" Horizontal Resaw Bandsaw |