Grizzly G0504 owner manual Symptom Possible Cause Possible Solution

Page 47

Symptom

 

Possible Cause

Possible Solution

Machine

has

1.

Motor or component is loose.

1.

Retighten/replace stripped or damaged bolts/nuts.

excessive

vibra-

2.

Blade weld at fault or teeth are broken.

2.

Replace blade.

tion or noisy oper-

3.

V-belt(s) worn or loose.

3.

Inspect/replace belts (refer to Page 37).

ation.

 

 

 

4.

Motor fan is rubbing on fan cover.

4.

Replace dented fan cover; replace loose/damaged fan.

 

 

 

 

 

 

 

 

5.

Pulley is loose.

5.

Realign/replace shaft, pulley, setscrew, or key.

 

 

 

 

6.

Machine incorrectly mounted.

6.

Tighten/replace floor mounts; relocate/shim machine.

 

 

 

 

7.

Motor bearings are at fault.

7.

Replace bearings.

 

 

 

 

8.

Blade is at fault.

8.

Replace warped, bent, or twisted blade; resharpen dull

 

 

 

 

 

 

 

blade.

 

 

 

 

 

 

Machine

slows

1.

Feed rate is too fast.

1.

Slow down the feed rate.

when cutting.

 

2.

Wood has a high moisture content.

2.

Only cut properly dried wood.

 

 

 

 

3.

V-belt does not have enough tension

3.

Tighten the V-belt (Page 36).

 

 

 

 

 

and is slipping on the pulleys.

 

 

 

 

 

 

4.

V-belt is worn out.

4.

Replace V-belt (Page 37).

 

 

 

 

 

Blade does not

1.

Blade support bearings set incorrectly.

1.

Adjust blade support bearings (Page 21).

run evenly on

 

2.

Wheels have built up pitch or dust.

2.

Clean wheels of all pitch and dust.

the wheels.

 

3.

Wheels are not coplanar.

3.

Call the Grizzly Service Department at (570) 546-9663 for

 

 

 

 

 

 

 

help determining if your wheels really are NOT coplanar;

 

 

 

 

 

 

 

adjust wheels to be coplanar as described on Page 41.

 

 

 

 

4.

Shape of wheels has changed from

4.

Replace wheels.

 

 

 

 

 

long term use and wear.

 

 

 

 

 

 

 

 

Blade

does not

1.

Blade is not properly tensioned.

1.

Adjust blade tension (Page 19).

cut evenly.

 

 

2.

Wheels are not coplanar.

2.

Call the Grizzly Service Department at (570) 546-9663 for

 

 

 

 

 

 

 

help determining if your wheels really are NOT coplanar;

 

 

 

 

 

 

 

adjust wheels to be coplanar as described on Page 41.

 

 

 

 

3.

Tooth set is uneven.

3.

Replace blade.

 

 

 

 

4.

Teeth are sharper on one side than the

4.

Replace blade.

 

 

 

 

 

other.

 

 

 

 

 

 

 

 

 

Blade

makes

a

1.

V-belt is loose.

1.

Tighten the V-belt (Page 36).

squealing

noise,

2.

V-belt is worn out.

2.

Replace V-belt (Page 37).

especially

 

on

 

 

 

 

startup.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ticking

 

sound

1.

Blade weld is contacting the guide

1.

Use the Model G2516 stone to smooth the blade weld.

when the

saw

is

 

blocks or support bearing.

 

 

running.

 

 

 

 

 

 

Hydraulic pump is

1.

Pump is restricted.

1.

Inspect and clean breather cap, filter, and tank screen.

noisy or hydraulic

2.

Filter is clogged.

2.

Perform minor service (Page 32).

system

operates

3.

Tank screen is clogged.

3.

Perform major service (Page 33).

erratically.

 

 

4.

Damaged hydraulic pump or motor.

4.

Replace pump or motor. See hydraulic specialist.

 

 

 

 

 

 

 

 

 

 

 

 

G0504 16" Horizontal Resaw Bandsaw

-45-

Image 47
Contents Model G0504 Horizontal Resaw Bandsaw Page Table of Contents Parts Service AdjustmentsCommentary General InformationMachine Data Sheet G0504 16 Horizontal Resaw Bandsaw G0504 16 Horizontal Resaw Bandsaw Additional Safety Instructions for Bandsaws Additional Safety Instructions for Hydraulics Circuit Requirements Phase PowerInside of electrical box Grounding Converting toMain motor 440V wiring Main Features Machine FeaturesPage Control Panel Memory Preset Keys A, B, C, D-AllowsUnpacking SET UPAbout this Section Piece InventoryHardware Recognition Chart Clean Up Site Considerations Mounting Resaw to the Floor Removing Resaw from Crate PalletTo install and tension the blade Installing Tensioning BladeAlways de-tension blade after use Adjusting Blade GuidesTo adjust the support bearings To adjust the upper guide block Support BearingTo connect the resaw to a dust collector Connecting to DustPower Source Test Run Power on switchTo operate the infeed conveyor Operation Safety Conveyor ControlsOperations To calibrate the digital display Setting Blade HeightCalibrating Digital Display To set the blade height with the keypadTo set the memory function Setting Memory Using Memory ButtonTo store a height in the a memory preset key To use the stored memory preset in the a keyTo perform a resawing operation ResawingBlade Information H1300 H1298 G7984 H2347 H0736 AccessoriesH4959-Coolant Dispenser H0580-Pneumatic Grease GunBelts MaintenanceCleaning MiscellaneousGrease Fittings Check the hydraulic fluid level daily Hydraulic System Minor ServiceTo inspect the hydraulic fluid Hydraulic System Major ServiceTo fill the tank with new fluid To clean the tank screenTo clean the bottom of the tank Adjusting Lower Blade Guides Service AdjustmentsAbout Service To adjust the tension for the hydraulic pump V-belt Adjusting V-Belt TensionTo check the main conveyor table alignment Adjusting Main Conveyor TableReplacing V-Belts To set the conveyor tracking Tracking ConveyorsTo replace the conveyor belts Replacing ConveyorsDisconnect the resaw from the power source Blade Tracking Wheel Alignment Screws Page Underpowered TroubleshootingSymptom Possible Cause Possible Solution Parts Housing PartsDescription Housing Parts ListFrame Parts Frame Parts List Elevation Parts Elevation Parts List Blade Guide Parts Adjustment ROD Bracket Tensioning Wheel Parts Tensioning Wheel Parts List Drive Wheel Parts Hydraulic Pump Parts Main Conveyor Table Parts Main Conveyor Table Parts List Return Conveyor Table Parts Rear Hold Down Parts Front Hold Down Parts Front Hold Down Parts List Hydraulic System Parts Connector 3/8H X 3/8H Hydraulic System Parts ListElectrical System Parts Electrical System Parts Electrical System Parts List Warranty and Returns Page Page Page