Bard I42H1D, I36H1D, I60H1D, I48H1D, I30H1D installation instructions Bracket Wall Section View

Page 10

BRACKET WALL SECTION VIEW

Optional

Duct

Ceiling

Optional

Trim or

Supply Duct

Box

Unit

Floor

Outside

Optional Top

 

 

3

 

 

 

3"

Bracket

 

 

 

 

 

 

 

43 8

"

 

 

 

Wall

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(4) optional Unit

 

 

 

 

 

 

 

Telescoping

Mounting holes

 

7

 

 

7

 

 

 

20

"

20

"

6"

Wall Sleeve**

 

8

8

 

Sleeve Mounting

 

 

 

 

 

 

 

 

Hole Locations

 

 

 

 

 

 

 

 

Centered on

 

 

 

Centered

 

 

Opening

 

 

 

 

 

 

 

 

 

 

 

 

Outside

 

 

 

42-3/4" Min.

20"

 

 

 

 

 

Wall

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

43-1/4" Max.

 

 

 

 

 

94 81 "

 

 

 

48" Min.

 

49

3

"

 

 

 

 

 

48-1/2" Max.

 

8

 

 

Grille

 

Centered

 

 

20"

 

 

56 21 "

 

 

 

 

 

 

 

 

 

 

(4) optional Unit

 

 

 

 

 

 

 

 

 

 

Mounting holes

 

 

 

 

 

 

 

 

 

 

 

 

8"

20

7

8"

4

1611 "

 

 

31" Min.*

15

8 "

 

 

 

 

 

 

34" Max.

1 16

"

 

 

 

 

 

 

29

17

"

*

 

 

20"

 

20"

 

 

 

32

31" Min.

 

 

 

 

 

 

 

 

 

34" Max.

 

 

 

43 87 "

Room Floor Level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

C

 

L

L

18 3/4

7 3/8

17.5"

 

 

Right Side View

 

35"

Front (Wall Only) View

 

*Higher Sill Heights Acheivable With Base Kit.

**Separate telescoping sleeves available for different wall thicknesses.

FLOOR MOUNTING HOLE & CENTERLINES

MIS-2918 C

WOOD FRAMED INSTALLATION (for Wall Attachment)

41.75

Inner wall

(4) Upper fastener holes

6.00

Unit

(4) lower fastener

holes

56.50

8.00

29.56*

20.88

36.888.00

Floor* Height dimension shown without riser kit. If unit uses riser kit add appropriate dimension to height.

MIS-3072

Manual

2100-549G

Page

10 of 59

Image 10
Contents TEC Series Packaged Heat Pump Contents Getting Other Information and Publications For More INFORMATION, Contact These PublishersGeneral Ansi Z535.5 DefinitionsFactory BUILT-IN Electric Heat Table Indoor Blower PerformanceElectrical Specifications Unit Specification Sheet Unit DimensionsUnit Removal from Skid Shipping DamageHandling Unit After Removal from Skid Seismic Considerations Minimum Installation HeightWall Mounting Bracket Location Bracket Wall Section View Center of Gravity Center of GravityRequired Clearances & Recommended Access Compressor Shipping Bolts Removal of AIR DuctDucted Application Basic Unit 3 Riser Application 6 Riser Application Supply Duct Connections Duct WorkFilters Filter LocationWith no Vent Option With Energy Recovery VentilatorCondensate Drain With Commercial Room VentilatorUnit Mounting 16 3/4 NON-TAPPING 16 1/2 NON-TAPPINGTEC Unit Mounting the Unit Wiring Main PowerComponent Location Operating Voltage Range Wiring LOW Voltage WiringLOW Voltage Connections Wall ThermostatsBasic Heat Pump with no Ventilation Package SC SC SCY2 B/W1 W2 W3 CRV Wiring Harness Heat Pump with CRV, Without CO2 ControlHeat Pump with CRV and CO2 Control To functionERV Wiring Harness Heat Pump with ERV, Without CO2 ControlHeat Pump with ERV and CO2 Control ON/OFF Cycling ERV Wiring Harness Bard #8403-067 Heat Pump with ERV and CO2 Control Fully ModulatingHeat Pump with Combination CRV and DB Economizer N Vent Code Safety Practices Topping OFF System ChargeThree Phase Scroll Compressor Start UP Information Important Installer NotePhase Monitor Service HintsSequence of Operation Pressure Service PortsSound Defrost Cycle Defrost CycleTeccommercial Room Ventilator System General Description Control WiringSetting the Ventilation CFM Levels Recommended Control SequencesCRV Motor SPEED/CFM Configuration Vent Option INTAKE/EXHAUST SpeedsCRV Speed Change Terminal Access Control Wiring TECECON. Sequence of Operation Economizer Control CircuitVentilation Mode Heating Mode OperationMotor SPEED/CFM Configuration Tecenergy Recovery Ventilator System General Description Changing Ventilation CFM Rates in Manual Mode Changing to Fully Modulating ModePerformance and Application Data Winter Heating Performance Indoor Design Conditions 70F DBERV Manual Mode Jumper PIN on M Terminal ERV Modulating Mode Jumper PIN on P TerminalVentilation Airflow Diagram Indoor Air Supply Air Outdoor AirERV Access Specifications Control Board CONFIGURATION/SETTINGMounting WiringAccessing Menu Parameters Selection of Voltage OutputsMenu Descriptions Maintenance Procedures Quarterly Maintenance Energy Recovery Ventilator Maintenance General InformationCleanability and Performance FrequencyAnnual Maintenance Troubleshooting Solid State Heat Pump Control Troubleshooting ProcedureCodes Function Checking Temperature Sensor Temperature F VS Resistance R of Temperature SensorTroubleshooting ECM 142R Outdoor FAN Motor Heat Pump Mode Troubleshooting ECM 142R Outdoor FAN MotorCooling Mode Replacing the MotorTroubleshooting Indoor ECM Blower Motors Troubleshooting Indoor ECM Blower Motors Cont’d Power Connector Motor Half FAN Blade Setting DimensionsControl Connector Motor Half Refrigerant ChargeFull Load Cooling PRESSURE/TEMPERATURE Full Load Heating PRESSURE/TEMPERATUREPart Load Cooling PRESSURE/TEMPERATURE Part Load Heating PRESSURE/TEMPERATURE