Regent Sheffield CMS249RW manual Alarm tone sequence, Lamp control, Manual lamp control

Page 5
your local retailer.

NOTE: The indoor alarm/lamp control module can

 

 

be purchased separately (Model RM249). Contact

Volume

 

your local retailer.

 

control

 

Your indoor alarm/lamp control module is ready to

 

 

plug in and use. There is no installation required!

Modes of

Lamp

This module sounds four distinctive and easily heard

operation

plug-in

 

warning tones and can turn on any lamp up to 300

 

House

watts that is plugged into the module. Any Regent model

codes

MS249 outdoor motion detector set to the same house code

 

as the indoor alarm/lamp module will activate the module to

P

 

sound an alarm and turn on the lamp plugged into it. Use up to

 

four detectors and indoor alarm/lamp modules in each house. NOTE:If you are not receiving adequate performance using a given house code, move the module to a different outlet. Remember, both the sensor and module must be on the same house code at any given time.

Step 1: Plug lamp into the module (optional). Make sure the lamp does not exceed 300 watts and that the switch on the lamp is in the ON position. Make sure MODE OF OPERATION switch is in any position except OFF.

Step 2: Plug module into any wall outlet. If the outlet is a switched outlet, make sure wall switch which operates the outlet is in the ON position. The module is now on. Allow the module to stabilize for 15 seconds. The module may sound a tone sequence during stabilization. This is normal.

Step 3: Activate outdoor motion detector. If the outdoor sensor is set to the same house code as the indoor alarm/lamp module, module will sound a distinctive warning tone sequence. A volume control (HIGH, MEDIUM, LOW, OFF) is located on the side of the module to set the desired sound level. If you desire the lamp to come on but do not want the alarm to sound, turn the volume control to OFF.

If you want to turn off both the alarm and lamp, slide MODE OF OPERATION switch to OFF.

Alarm tone sequence

The tone sequence corresponds to the house code setting so that you can tell which outdoor light is being activated (if more than one is in use).

House Code #1 = Single tone repeats two times

House Code #2 = Double tones repeat two times

House Code #3 = Triple tones repeat two times

House Code #4 = Quadruple tones repeat two times

Lamp control

At night and in AUTO mode, the indoor lamp will also turn on when motion is detected. If the outdoor sensor is in the AUTO mode, the lamp will only turn on at night (when in AUTO mode, the indoor lamp will only turn on when the outside lights turn on). The indoor lamp (when activated in the AUTO mode) will remain on for 10 minutes after motion ceases outdoors and then will automatically turn off regardless of the “time on” setting of the sensor.

Manual lamp control

The indoor lamp can be easily turned on and off manually, both day and night, by sliding the MODE OFOPERATION switch on the left side of the module to LAMPON. While the lamp is manually switched on, the alarm will continue to sound tone sequences when motion is detected. To return to the lamp only coming on with motion, slide the switch back to AUTO.

5

Image 5
Contents Page How it works MS249R, CMS249R Bronze MS249RW, CMS249RW WhiteWhat you need What’s includedYour fixture mounts For best resultsSAVE THESE INSTRUCTIONS Indoor alarm/lamp control module operation guide P How to operate your fixtureSwitch setting House code selections on sensor head OYour indoor alarm/lamp control module is ready to Alarm tone sequenceplug in and use. There is no installation required Lamp controlSet slide switch How to select your desired feature of the motion detectorHow to set Mode ofcontinued What to do ifTwo year limited warranty There are no express warranties except as described above Cómo funciona MS249R, CMS249R Bronce MS249RW, CMS249RW BlancoQué se requiere Qué se incluyeGUARDE ESTAS INSTRUCCIONES Para obtener mejores resultadosMontaje de su portalámparas Operación de su portalámparas Selección de los códigos de casa en el cabezal del sensor O NOTA El módulo de control de la alarma/lámpara Control dePosiciones del TonosControl de la lámpara Sequencia del tono de la alarmaControl manual de la lámpara Cómo elegir la función deseada del detector de movimientoColoque el interruptor continuación Qué hacer siEn caso positivo, asegúrese que el conmutador en la pared está La lámpara interior se prendera solamente cuando las luces exteImpreso en China Dos años de garantía limitadaPatentes 5,381,3235,515,252y otras patentes pendientes Comment votre projecteur fonctionne MS249R, CMS249R Bronze MS249RW, CMS249RW BlancCe dont vous avez besoin Ce qui est compris dans cet ensembleMontage du dispositif Pour de meilleurs résultatstrois types de boîte de connexion CONSERVER CES INSTRUTCIONSEtape Comment faire fonctionner votre dispositifH . . . . . 18 m ou plus portée maximale REMARQUE La température peut affecter la sensibilité du détecteurTout modèle extérieur Regent MS249 configuré branchée, d’une puissance pouvant atteindre 300 watts . volumeavec le même code domestique que lampe/alarme intérieure activera l’alarme sonore et allumera laContrôle de la lampe intérieure Séquence de la tonalité d’alarmeContrôle manuel de la lampe intérieure suiteQue faire si suite Garantie limitée de deux ans L’ALARME INTÉRIEURE NE SE FAIT PAS ENTENDRELA LAMPE INTÉRIEURE NE S’ALLUME PAS LA LAMPE INTÉRIEURE NE S’ÉTEINT PASPage Imprimé en Chine 6/06 REMARQUESBrevets 5,381,3235,515,252et d’autres brevets déposés