Schneider Electric Altivar 212 manual Power and energy, Maintenance, Values, Trip and alarm codes

Page 47

Parameter list

Power and energy

 

Parameter

Modbus

Unit

Description

 

 

address

 

 

 

 

 

 

 

 

 

Input power (FE29)

65065

16#FE29

kW

Value before trip

 

 

 

 

 

 

 

Output power (FE30)

65072

16#FE30

kW

Value before trip

 

 

 

 

 

 

 

Input energy (FE76)

65142

16#FE76

kWh

-

 

 

 

 

 

 

 

Output energys (FE77)

65143

16#FE77

kWh

-

 

 

 

 

 

 

Maintenance

 

 

 

 

 

 

 

 

 

 

Parameter

Modbus

Unit

Description

 

 

address

 

 

 

 

 

 

 

 

 

Motor load (FE26)

65062

16#FE26

%

Value before trip

 

 

 

 

 

 

 

Inverter load (FE27)

65063

16#FE27

%

Value before trip

 

 

 

 

 

 

 

Cumulative run time (FE14)

65044

16#FE14

h

-

 

 

 

 

 

 

 

Cumulative power on time (FE80)

65152

16#FE80

h

-

 

 

 

 

 

 

I/O values

 

 

 

 

 

 

 

 

 

Parameter

Modbus

Description

 

 

address

 

 

 

 

 

 

 

 

Digital inputs status Fd06

64774

16#Fd06

Current value

 

 

 

 

 

 

Digital outputs status Fd07

64775

16#Fd07

Current value

 

 

 

 

 

 

Digital inputs status at last trip FE06

65030

16#FE06

Value before trip

 

 

 

 

 

 

Digital outputs status at last trip FE07

65030

16#FE07

Value before trip

 

 

 

 

 

 

 

Analog input VIA value FE35

65077

16#FE35

-

 

 

 

 

 

 

 

 

Analog input VIB value FE36

65078

16#FE36

-

 

 

 

 

 

 

 

Trip and alarm codes

Parameter

Modbus address

Description

Trip code FC90

64656 16#FC90

-

 

 

 

Alarm code FC91

64657 16#FC91

-

 

 

 

Alarm of run FE79

65145 16#FE79

-

 

 

 

Latest trip code FE10

65040 16#FE10

-

 

 

 

2nd previous trip code FE11

65041 16#FE11

-

 

 

 

3rd previous trip code FE12

65042 16#FE12

-

 

 

 

4th previous trip code FE13

65043 16#FE13

-

 

 

 

S1A53844 01/2011

47

Image 47
Contents Altivar S1A53844 01/2011 Table of Contents Table of Contents Important Information Safety InformationAt a Glance About the BookHazard of Electric SHOCK, Explosion or ARC Flash S1A53844 01/2011 Introduction Introduction Topic Hardware setupWhats in this Chapter? Tightening torque Pin out of the Open Style Modbus connectorRJ45 Cross sectionOpen Style Reference Connection via Open Style wiring systemPin out of the RJ45 Modbus connector Pin SignalRJ45 Reference Connection via RJ45 wiring systemConnection accessories Connecting cablesProtection Against Interference PTC resistor value F646 Description of terminalsGND Hardware setup Configuration After Configuration of the communication parametersAccess to the parameters Parameters Modbus Adjustment range Default Valid AddressCommunication Configuration of the control sourceParameters Modbus Setting Control by the Modbus networkParameters Setting Default ValidControl by the terminals, monitoring by the Modbus network Parameters Modbus Setting Default Valid LI R selection Parameters Modbus Setting Default Valid AddressCom channel choice F807 Communication Menu COM submenu LI R selection F112VIA VIA Parameters LocationRemote spd ref 2 F207 Frequency sourceCommands CMOd Complete control diagramConfiguration Configuration of the indirect blocksConfiguration of the communication interruption 2129 Configure the drive behaviourParameter Modbus Setting Default Valid Address Communication detected fault 16#851Configuration Modbus services Slave address Function code Data RTU modePrinciple of the Modbus protocol Slave Slave j Slave kFunction 3, quantity = Modbus functions availableRead one word Status info Read indirect blockFunction 3, quantity = 1 Read indirect block of 2 parameters Write Single Register Function 16 = 16#10, quantity =1 Write multiple registersSpeed Setpoint Command word Frequency SetpointWrite indirect block Request 6C 7E Response Read Device Identification 43/14 Exception code Error responseModbus services Parameter list General Auto ramp AUI Disabled ManualSetting of Max frequency FH Referring to the Altivar 212 programming manualOutputs control from serial communication Commands from serial communicationList of control parameters Setpoints from serial communicationCurrent and torque List of monitoring parametersStatus Frequency and speedValues Power and energyMaintenance Trip and alarm codesBit Specifications Remarks CommandsCommand word FA00 Over-current stall level change bit Command word 2 FA20Energy reset bit ExamplesSpeed setpoint FA13 SetpointsFrequency setpoint FA01 Status word FE0I Fd01 StatusStatus word 3 FE49 Fd49 Command mode status FE45Setpoint mode status FE46 Status word 2 FE42 Fd42Alarm of run time FE79 Trip and alarm codesAlarm code FC91 Code Value Description Hexadecimal number Decimal number Bit Terminal name Function parameter title Monitoring and control of I/O from communicationDigital inputs status Fd06, FE06 Digital outputs status Fd07, FE07Analog inputs values FE35, FE36 Digital outputs command FA50Analog outputs command FA51 Damper opening commandF580 = 3 Drive model code F805 Model Voltage Power Rating Code FB05 Class FB72bit8Identification ATV212WU15N4C S1A53844 01/2011 Appendix RS485 standard Modbus 2-wire standard schematicSchematic diagram Migration Commissioning Migration ATV21 ATV212For example ATV212Modbus manualENS1A5384401 S1A53844 01/2011