Schneider Electric
Altivar 212
manual
Introduction
Specs
Complete control diagram
Pin Signal
Setting Default Valid
Connecting cables
Maintenance
Configuration
Energy reset bit
Access to the parameters
Hardware setup
Page 10
Introduction
10
S1A53844 01/2011
Page 9
Page 11
Image 10
Page 9
Page 11
Contents
Altivar
S1A53844 01/2011
Table of Contents
Table of Contents
Safety Information
Important Information
About the Book
At a Glance
Hazard of Electric SHOCK, Explosion or ARC Flash
S1A53844 01/2011
Introduction
Introduction
Whats in this Chapter?
Hardware setup
Topic
Cross section
Pin out of the Open Style Modbus connector
RJ45
Tightening torque
Pin Signal
Connection via Open Style wiring system
Pin out of the RJ45 Modbus connector
Open Style Reference
Connecting cables
Connection via RJ45 wiring system
Connection accessories
RJ45 Reference
Protection Against Interference
Description of terminals
PTC resistor value F646
GND
Hardware setup
Configuration
Parameters Modbus Adjustment range Default Valid Address
Configuration of the communication parameters
Access to the parameters
After
Control by the Modbus network
Configuration of the control source
Parameters Modbus Setting
Communication
Control by the terminals, monitoring by the Modbus network
Setting Default Valid
Parameters
Parameters Modbus Setting Default Valid
LI R selection F112
Parameters Modbus Setting Default Valid Address
Com channel choice F807 Communication Menu COM submenu
LI R selection
Frequency source
Parameters Location
Remote spd ref 2 F207
VIA VIA
Complete control diagram
Commands CMOd
Configuration of the indirect blocks
Configuration
Configuration of the communication interruption
Communication detected fault 16#851
Configure the drive behaviour
Parameter Modbus Setting Default Valid Address
2129
Configuration
Modbus services
Slave Slave j Slave k
RTU mode
Principle of the Modbus protocol
Slave address Function code Data
Read one word
Modbus functions available
Function 3, quantity =
Function 3, quantity = 1
Read indirect block
Status info
Read indirect block of 2 parameters
Write Single Register
Write multiple registers
Function 16 = 16#10, quantity =1
Write indirect block
Command word Frequency Setpoint
Speed Setpoint
Request 6C 7E Response
Read Device Identification 43/14
Error response
Exception code
Modbus services
Parameter list
Referring to the Altivar 212 programming manual
Auto ramp AUI Disabled Manual
Setting of Max frequency FH
General
Setpoints from serial communication
Commands from serial communication
List of control parameters
Outputs control from serial communication
Frequency and speed
List of monitoring parameters
Status
Current and torque
Trip and alarm codes
Power and energy
Maintenance
Values
Command word FA00
Commands
Bit Specifications Remarks
Examples
Command word 2 FA20
Energy reset bit
Over-current stall level change bit
Frequency setpoint FA01
Setpoints
Speed setpoint FA13
Status
Status word FE0I Fd01
Status word 2 FE42 Fd42
Command mode status FE45
Setpoint mode status FE46
Status word 3 FE49 Fd49
Alarm code FC91
Trip and alarm codes
Alarm of run time FE79
Code Value Description Hexadecimal number Decimal number
Digital outputs status Fd07, FE07
Monitoring and control of I/O from communication
Digital inputs status Fd06, FE06
Bit Terminal name Function parameter title
Damper opening command
Digital outputs command FA50
Analog outputs command FA51
Analog inputs values FE35, FE36
F580 = 3
Identification
Model Voltage Power Rating Code FB05 Class FB72bit8
Drive model code F805
ATV212WU15N4C
S1A53844 01/2011
Appendix
Schematic diagram
Modbus 2-wire standard schematic
RS485 standard
Migration
For example
Migration ATV21 ATV212
Commissioning
ATV212Modbus manualENS1A5384401 S1A53844 01/2011
Related pages
Print Cartridge Life Specifications for HP 600 C2184A
3.8Error Messages for Furuno SC-110
NVidia MCP55 Pro Chipset System Block Diagram for SUPER MICRO Computer H8DMT
Fo~et a dish? Here’s when vou can add it for Hotpoint HDA850G
Installing the software »Convert« onto a PC for Silvercrest KH 2450
SCANNER4 in 1 Parts List for Samsung SCX-4600
Language Code List for Mitsubishi Electronics DD-6040
What are the possible causes if my chainsaw won't start?
Explore troubleshooting steps
Top
Page
Image
Contents