Schneider Electric Altivar 212 manual Identification, Drive model code F805

Page 58

 

 

 

 

Parameter list

 

 

 

 

 

Identification

 

 

 

drive model code (F805)

 

 

 

 

 

 

 

 

 

Model

Voltage Power Rating

Code (FB05)

Class (FB72:bit8)

 

 

 

 

 

 

ATV212H075M3X

3ph 200V 0.75kW

4

0

 

 

 

 

 

 

ATV212HU15M3X

3ph 200V 1.5kW

6

0

 

 

 

 

 

 

ATV212HU22M3X

3ph 200V 2.2kW

7

0

 

 

 

 

 

 

ATV212HU30M3X

3ph 200V 3kW

8

0

 

 

 

 

 

 

ATV212HU40M3X

3ph 200V 3.7kW / 4kW

9

0

 

 

 

 

 

 

ATV212HU55M3X

3ph 200V 5.5kW

10

0

 

 

 

 

 

 

ATV212HU75M3X

3ph 200V 7.5kW

11

0

 

 

 

 

 

 

ATV212HD11M3X

3ph 200V 11kW

108

0

 

 

 

 

 

 

ATV212HD15M3X

3ph 200V 15kW

109

0

 

 

 

 

 

 

ATV212HD18M3X

3ph 200V 18.5kW

110

0

 

 

 

 

 

 

ATV212HD22M3X

3ph 200V 22kW

111

0

 

 

 

 

 

 

ATV212HD30M3X

3ph 200V 30kW

112

0

 

 

 

 

 

 

ATV212H075N4

3ph 400/460V 0.75kW

36

0

 

 

 

 

 

 

ATV212HU15N4

3ph 400/460V 1.5kW

38

0

 

 

 

 

 

 

ATV212HU22N4

3ph 400/460V 2.2kW

39

0

 

 

 

 

 

 

ATV212HU30N4

3ph 400/460V 3.0kW

40

0

 

 

 

 

 

 

ATV212HU40N4

3ph 400/460V 3.7/4 kW

41

0

 

 

 

 

 

 

ATV212HU55N4

3ph 400/460V 5.5kW

42

0

 

 

 

 

 

 

ATV212HU75N4

3ph 400/460V 7.5kW

43

0

 

 

 

 

 

 

ATV212HD11N4

3ph 400/460V 11kW

44

0

 

 

 

 

 

 

ATV212HD15N4

3ph 400/460V 15kW

45

0

 

 

 

 

 

 

ATV212HD18N4

3ph 400/460V 18.5kW

46

0

 

 

 

 

 

 

ATV212HD22N4S

3ph 400/460V 22kW

32

0

 

 

 

 

 

 

ATV212HD22N4

3ph 400/460V 22kW

47

0

 

 

 

 

 

 

ATV212HD30N4

3ph 400/460V 30kW

48

0

 

 

 

 

 

 

ATV212HD37N4

3ph 400/460V 37kW

49

0

 

 

 

 

 

 

ATV212HD45N4

3ph 400/460V 45kW

50

0

 

 

 

 

 

 

ATV212HD55N4

3ph 400/460V 55kW

51

0

 

 

 

 

 

 

ATV212HD75N4

3ph 400/460V 75kW

52

0

 

 

 

 

 

 

ATV212W075N4

3ph 400/460V 0.75kW IP54

0136

0

 

 

 

 

 

 

ATV212WU15N4

3ph 400/460V 1.5kW IP54

0138

0

 

 

 

 

 

 

ATV212WU22N4

3ph 400/460V 2.2kW IP54

0139

0

 

 

 

 

 

 

ATV212WU30N4

3ph 400/460V 3.0kW IP54

0140

0

 

 

 

 

 

 

ATV212WU40N4

3ph 400/460V 3.7/4 kW IP54

0141

0

 

 

 

 

 

 

ATV212WU55N4

3ph 400/460V 5.5kW IP54

0142

0

 

 

 

 

 

 

ATV212WU75N4

3ph 400/460V 7.5kW IP54

0143

0

 

 

 

 

 

 

ATV212WD11N4

3ph 400/460V 11kW IP54

0144

0

 

 

 

 

 

 

ATV212WD15N4

3ph 400/460V 15kW IP54

0145

0

 

 

 

 

 

 

ATV212WD18N4

3ph 400/460V 18.5kW IP54

0146

0

 

 

 

 

 

 

ATV212WD22N4S

3ph 400/460V 22kW IP54

32

0

 

 

 

 

 

 

ATV212WD22N4

3ph 400/460V 22kW IP54

0147

0

 

 

 

 

 

 

ATV212WD30N4

3ph 400/460V 30kW IP54

0148

0

 

 

 

 

 

 

 

 

 

 

58

 

 

 

S1A53844 01/2011

Image 58
Contents Altivar S1A53844 01/2011 Table of Contents Table of Contents Safety Information Important InformationAbout the Book At a GlanceHazard of Electric SHOCK, Explosion or ARC Flash S1A53844 01/2011 Introduction Introduction Whats in this Chapter? Hardware setupTopic Cross section Pin out of the Open Style Modbus connectorRJ45 Tightening torquePin Signal Connection via Open Style wiring systemPin out of the RJ45 Modbus connector Open Style ReferenceConnecting cables Connection via RJ45 wiring systemConnection accessories RJ45 ReferenceProtection Against Interference Description of terminals PTC resistor value F646GND Hardware setup Configuration Parameters Modbus Adjustment range Default Valid Address Configuration of the communication parametersAccess to the parameters AfterControl by the Modbus network Configuration of the control sourceParameters Modbus Setting CommunicationControl by the terminals, monitoring by the Modbus network Setting Default ValidParameters Parameters Modbus Setting Default Valid LI R selection F112 Parameters Modbus Setting Default Valid AddressCom channel choice F807 Communication Menu COM submenu LI R selectionFrequency source Parameters LocationRemote spd ref 2 F207 VIA VIAComplete control diagram Commands CMOdConfiguration of the indirect blocks ConfigurationConfiguration of the communication interruption Communication detected fault 16#851 Configure the drive behaviourParameter Modbus Setting Default Valid Address 2129Configuration Modbus services Slave Slave j Slave k RTU modePrinciple of the Modbus protocol Slave address Function code DataRead one word Modbus functions availableFunction 3, quantity = Function 3, quantity = 1 Read indirect blockStatus info Read indirect block of 2 parameters Write Single Register Write multiple registers Function 16 = 16#10, quantity =1Write indirect block Command word Frequency SetpointSpeed Setpoint Request 6C 7E Response Read Device Identification 43/14 Error response Exception codeModbus services Parameter list Referring to the Altivar 212 programming manual Auto ramp AUI Disabled ManualSetting of Max frequency FH GeneralSetpoints from serial communication Commands from serial communicationList of control parameters Outputs control from serial communicationFrequency and speed List of monitoring parametersStatus Current and torqueTrip and alarm codes Power and energyMaintenance ValuesCommand word FA00 CommandsBit Specifications Remarks Examples Command word 2 FA20Energy reset bit Over-current stall level change bitFrequency setpoint FA01 SetpointsSpeed setpoint FA13 Status Status word FE0I Fd01Status word 2 FE42 Fd42 Command mode status FE45Setpoint mode status FE46 Status word 3 FE49 Fd49Alarm code FC91 Trip and alarm codesAlarm of run time FE79 Code Value Description Hexadecimal number Decimal number Digital outputs status Fd07, FE07 Monitoring and control of I/O from communicationDigital inputs status Fd06, FE06 Bit Terminal name Function parameter titleDamper opening command Digital outputs command FA50Analog outputs command FA51 Analog inputs values FE35, FE36F580 = 3 Identification Model Voltage Power Rating Code FB05 Class FB72bit8Drive model code F805 ATV212WU15N4C S1A53844 01/2011 Appendix Schematic diagram Modbus 2-wire standard schematicRS485 standard Migration For example Migration ATV21 ATV212Commissioning ATV212Modbus manualENS1A5384401 S1A53844 01/2011