Carrier 50PTH specifications 50PTV Dimensional Data

Page 6

 

LEGEND

 

 

 

ASP

Alternate Service Panel

Field-Installed

 

BSP

Blower Service Panel

Discharge Flange

 

CAP

Control Access Panel

(shipped loose inside

Access Panels

CSP

Compressor Service Panel

blower section)

FPT

Female Pipe Thread

 

Filter Bracket

 

HV

High Voltage

 

HWG

Hot Water Generator

 

 

 

HWR

Hot Water Reheat

 

 

 

LV

Low Voltage

 

 

 

 

 

 

 

 

 

P

N

O

Front

 

 

 

Q

Air Coil Side

 

 

B

N

P

 

Front

Air Coil Side

Air Coil

O

A

CSP

M

BSP

CAP

ASP

ASP

2ʼ Service Access

K - Configuration - Right Return

/Top Discharge

(Top View)

J - Configuration - Left Return

/Top Discharge

(Top View)

S

R

U

 

Air Coil

T

R

S

U

 

Air Coil

T

2ʼ Service Access

Isometric View

1.00”

C

C

Power Supply 3/4”

1.68”

Condensate

3/4” FPT

 

 

 

1.18”

 

ASP

 

CSP

 

 

 

Front

Back

Back

Front

HV Knockout

1/2” Knockout

Low Voltage 1/2”

LV Knockout

CSP

1.63”

CAP

 

 

K

L

J

 

G

F

E

D H

 

K - Configuration - Right Return -

 

 

J - Configuration - Left Return -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Coil Opening

 

 

 

 

Air Coil Opening

 

 

 

 

 

 

 

Front View

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Right Side View)

 

 

 

 

 

(Left Side View)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WATER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OVERALL CABINET

 

 

 

 

 

 

 

 

CONNEC-

ELECTRICAL

DISCHARGE CONNECTIONS (in.)

RETURN CONNECTION

 

 

 

WATER CONNECTIONS (in.)

 

TIONS (in.)

DUCT FLANGE INSTALLED

USING AIR COIL OPENING

 

 

(in.)

 

 

 

 

KNOCKOUTS (in.)

 

 

 

 

 

 

 

 

 

 

 

- UNITS

 

 

(± 0.10 in.)

 

 

(in.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50PTV

 

 

 

 

 

 

 

 

 

 

 

WITH HWR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

 

 

 

 

 

 

 

 

 

 

 

 

 

J

K

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

Loop

 

1

2

1/2-in.

1/2-in.

3/4-in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HWG

M

 

O

 

P

 

Q

 

S

T

 

 

A

B

C

 

 

 

 

 

 

Water

FPT

 

 

Cond

Cond

Cond

(LH

N

Supply

Supply

 

(RH

R

Return

Return

U

 

Width

Depth

Height

 

 

 

F

G

H

FPT

 

 

 

 

 

 

 

 

D

E

(in.)

Loop

Loop

Low

Ext

Power

rtn)

 

Width

 

Depth

 

rtn)

 

Depth

Height

 

 

 

 

 

 

HWG

HWG

Cond-

(in.)

 

 

 

 

 

 

 

 

 

 

In

Out

In

Out

ensate

 

 

in D

out E

Voltage

Pump

Supply

 

 

 

 

 

 

 

 

 

 

 

026

22.4

25.6

48.5

 

2.1

10.0

13.9

16.9

7.8

3/4

1/2

2.1

10.0

3.6

6.1

8.6

7.2

5.8

14.0

 

14.0

 

4.9

2.2

21.1

27.2

1.0

038

25.4

30.6

50.5

 

3.4

10.8

15.6

18.9

7.8

3/4

1/2

5.96

13.13

3.6

6.1

8.6

6.4

6.3

18.0

 

18.0

 

5.3

2.2

26.1

27.2

1.0

049

25.4

30.6

54.5

 

3.4

10.8

15.6

18.9

7.8

1

1/2

5.96

13.13

3.6

6.1

8.6

6.4

6.3

18.0

 

18.0

 

5.3

2.2

26.1

31.2

1.0

064,

25.4

30.6

58.5

 

3.4

10.8

15.6

18.9

7.8

1

1/2

5.96

13.13

3.6

6.1

8.6

6.4

6.3

18.0

 

18.0

 

5.3

2.2

26.1

35.2

1.0

072

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

1.Condensate connection is stainless steel 3/4 in. female pipe thread (FPT).

2.Unit shipped with top and bottom filter rack and is not suitable for duct connection without additional support.

3.Discharge flange is field-installed.

4.Shaded areas are recommended service areas, not required.

AIRFLOW CONFIGURATION

CODE

RETURN

DISCHARGE

J

Left

Top

K

Right

Top

Fig. 3 — 50PTV Dimensional Data

6

Image 6
Contents Contents Safety ConsiderationsInstallation GeneralPhysical Data 50PTH, PTV, PTD026-072 Units 50PTH026-072 Dimensional Data Typical Installation 50PTH Unit Aux Electric Heat Disconnect50PTV Dimensional Data 50PTD Dimensional Data Side Discharge Back DischargeRotate Install Condensate DrainMount the Unit Move to SideHorizontal Unit Pitch Trap Condensate DrainTypical Ground-Water Piping Installation Drains field-installedWire Field Power Supply Water Quality GuidelinesMetal Hose Minimum Bend Radii 50PTH,PTV,PTD Electrical Data Alarm Relay Contacts Sensor, Water Coil Freeze ProtectionRVS TransECM BM ECM Alarm Relay Contacts Discharge Temp Switch Relay/Contactor Coil A50-8363 A50 8364LWT SPTA50-8571 Wshp Open ControlRnet Wiring Specifications Field-Supplied Sensors for Wshp Open ControllerSPT Sensors Wire Terminal Wire Field ControlsRnet Wiring A50-8443A50-8441 A50-8141A50-7764tf A50-8442Heating Settings Cooling SettingsDehumidificaton Mode Settings CFM Adjust SettingsBlower Performance Data PRE-START-UP Wshp Open Fan Only / Low Fan and Med Fan AirflowWshp Open High Fan Airflow Complete C Control Jumper Settings Deluxe D Control Jumper SettingsField Selectable Inputs Humidistat/Dehumidistat Logic Deluxe D DIP Switch Settings DIP Switch Block S2 Accessory 1 Relay OptionsDIP Switch Block S2 Accessory 2 Relay Options Units with Modulating Hot Water Reheat HWR OptionMode Input Output HWR Operating ModesA50-8145 Water Out START-UPOperating Limits Operating Limits 50PTH, PTV, PTD UnitsUnit Start-Up Cooling Mode Unit Start-Up Heating ModeWater Temperature Change Through Heat Exchanger Suction Discharge Super Sub Water Air Temp Unit Start-Up with Wshp Open Controls A50-8444PTD Unit 50PTH, PTV Water Temperature F GPMCoaxial Water Pressure Drop 026 038 049Operation Approximate Fluid Volume gal Per 100 Ft of PipeAntifreeze Percentages by Volume Units with Aquazone Complete C ControlUnits with Wshp Open Multiple Protocol Page Page LED Fault Description Code Complete C Control LED Code Fault DescriptionsLED Status Description of Operation Alarm Relay Complete C and Deluxe D Board System TestAlarm Relay Aquazone Deluxe D Control LED IndicaService Air Coil Fan Motor Removal TroubleshootingRefrigerant Charging Replacing the Wshp Open Controller’s Bat70.0 90.080.0 KOhm 60.0 50.0Page ECM Troubleshooting Fault Description SolutionECM Pin Connectors A50-8448ECM Troubleshooting Flow Diagram A50-8447Wshp Troubleshooting Fault Heating Cooling Possible Cause SolutionGood Practices Over/Under Voltage Code 7 Auto ResettingNo Fault Code Shown Performance MonitorLow Suction Pressure Temperature in HeatingHigh Head Pressure Low Discharge AirStatus Appendix a Wshp Open Screen ConfigurationAlarm Status SensorSystem Settings Appendix a Wshp Open Screen ConfigurationMaintenance ConfigurationSchedule Appendix a Wshp Screen Open Configuration ServiceTest Configuration Service Point Name Password Editable Range Default LevelScreen Name Alarm Page Page Copyright 2010 Carrier Corporation 50PTH,PTV,PTD START-UP Checklist II. START-UPA50-8449 Heating Cycle AnalysisCooling Cycle Analysis A50-8450