4 MAINTENANCE

Before carrying out any maintenance or repair:

1.Stop the compressor, switch off the voltage and open the isolating switch.

2.Close the air outlet valve (2-Figs. 1.2/1.4 or 3-Figs. 1.5/1.6) and open the manual drain valve: valve (1- Fig. 1.9) on Multi or the valve underneath the air receiver, if provided.

4.1 Compressor drive motors

The motor bearings are greased for life.

4.2 Preventive maintenance schedule for the compressor

The schedule comprises a summary of the maintenance instructions. Read the respective section before taking maintenance measures. The "longer interval" checks must also include the "shorter interval" checks.

Carry out the service operations at the period or running hours mentioned below, whichever interval comes first.

When servicing, replace all disengaged packings, e.g. gaskets, O-rings, washers.

Important

Use only authorized parts. Any damage or malfunction by the use of unauthorized parts is not covered by Warranty or Product Liability.

Service plans on SF Multi

A number of service operations are grouped in plans, called Service plans I, A, B or D; see the schedule below.

Each plan has a programmed time interval at which all service actions belonging to that plan are to be carried out.

When reaching the interval, a message will appear on the screen indicating which Service plans are to be carried out. After servicing, the intervals are to be reset. For detailed information, consult section 8.3.

Important

Always consult Atlas Copco in case any timer setting should be changed.

2920 1521 00

30

Image 30
Contents Instruction book No 1521 Registration code APC SF / 38Instruction book Skid Tank-mounted Twin Service warning message exists Leading Particulars General descriptionSF4 Skid Control panel Air outlet valve SF4 Tank-mounted SF8FF Multi Details of a compressor module on SF Tank-mounted Air flow Cooling and condensate drain systems FigRegulating system on SF Skid Tank-mounted Twin Protecting the compressorControlling the compressor Monitoring components subject to serviceRegulating system on SF Multi Automatic restart after voltage failureControl panel Fig Designation FunctionScroll keys 3-Fig Display keysOperating condition of a compressor module Tabulator key 4-FigSelecting a menu 13 Menu flow, SF MultiElectric cabinet on SF Multi 14 Electric cabinets, SF MultiAir dryer on SF Full-Feature Fig Compressed air circuitRefrigerant circuit Installation Dimension drawings Figs .1 up to9820 4054 00/1 Dimension drawing, SF 6-8 Multi Dimension drawing, SF 11-15 Multi Instruction book Installation proposal Fig Instruction book Electrical connections GeneralConnections Skid Tank-mounted Twin SF Multi TSHH20 Pictographs PictographsOperating Instructions Initial start-upStarting Taking out of operation at end of compressor service life During operationStopping Before carrying out any maintenance or repair MaintenancePreventive maintenance schedule for the compressor Service plans on SF MultiMonthly YearlyBelt exchange/tensioning Fig Adjustments and Servicing ProceduresAir filter 1-Figs .7/1.8 CoolersSafety valve TestingOperating Problem Solving Principal Data Electric cable size for SF1-8Electric cable size for SF 6-15 Multi Overload relays for SF1-8 Overload relays for SF6-15 MultiReference conditions/limitations Main fuses for SF1-8Main fuses for SF6-15 Multi Reference conditions10 SF1-4 100 psi 60 Hz SF1-4 8bar 50 HzSF2-4 10 bar 50 Hz 11 SF2-4 145 psi 60 Hz12 SF6-15 Multi 8 bar 50 Hz 13 SF6-15 Multi 10 bar 50 Hz14 SF6-15 Multi 100 psi 60 Hz SF11 SF15 125 psi 15 SF6-15 Multi 125 psi 60 Hz16 SF6-15 Multi 145 psi 60 Hz SF11 SF15 145 psiRegulator Functions for SF Multi Menu-driven control programsFunction of control programs Program/Function Description Main screenLine Indicates Remarks Element status screen, typical exampleProcedure Quick look at actual compressor statusCalling up other menus Status data menu No message existsShut-down message exists Shut-down reset Service warning message exists Measured data menuCounters menu Test menuModify parameters menu Modifying parametersModifying the pressure bands Modifying protection settings Checking protections for compressor modulesModifying service plans Service plansProgrammed service plan intervals Service plans Intervals Resulting service actions to be carried outService actions according to Programming start/stop/pressure band commands Programming Clock functionInstruction book To activate/deactivate the timer To modify a commandInstruction book Adding a command between two existing commands To delete commandsDeleting all commands related to a specific day Configuration menuDeleting all commands Deleting a specific start/stop/pressure band commandService menu Service plans ABI Saved data menu Programmable settings Regulation settings Minimum Nominal Maximum SettingService settings Minimum Nominal Maximum Setting Conversion List of SI Units Into US/BRITISH UnitsComponents subject to 97/23/EC Pressure Equipment Directive Part number Description PED ClassOverall Rating Instruction book Instruction book Wnership Data Safety Preca Utions