Instruction book
| Line | Indicates | Remarks | ||
| 
 | 
 | 
 | ||
| 1 | Sensor which is active | The unit for pressure can be bar, psi or kg/cm2 depending on the | ||
| programmed selection. The unit for temperature can be °C or °F. | ||||
| and the actual reading | ||||
| 
 | See section 8.12. | |||
| 
 | 
 | |||
| 2 | - | - | 
 | |
| 
 | 
 | Examples: | ||
| 3 | Compressor status | - | Compressor Off | |
| 
 | 
 | - | Compressor Running | |
| 
 | 
 | If the unit is shut down, the regulator will automatically show a shut- | ||
| 3 | down message on the display (see section 8.3). It remains possible | |||
| to have a closer look at other parameters related to the  | ||||
| 
 | 
 | |||
| 
 | 
 | by means of the menus. | ||
| 3 | Service required | Indicates that the unit needs servicing. Consult section 8.13 to find | ||
| out the exact cause for this message. | ||||
| 
 | 
 | |||
| 
 | 
 | Indicates that a sensor is out of order: | ||
| 
 | 
 | - | Outlet pressure transducer | |
| 3 | Sensor error | - | On  | |
| Stop the compressor. Switch off the voltage and depressurize the | ||||
| 
 | 
 | |||
| 
 | 
 | compressor. Check the sensor wiring. Replace the sensor or | ||
| 
 | 
 | transducer, if necessary. | ||
| 3 | Remote control | Indicates that the compressor is set in remote control. Consult Atlas | ||
| Copco. | ||||
| 
 | 
 | |||
| 4 | Functions of keys | See section 1.5.7. | ||
| below display | 
 | 
 | ||
| 
 | 
 | 
 | ||
| 
 | Symbols: | Indicating the status of each compressor module | ||
| 
 | 
 | 
 | ||
| 4 | - | indicating that the compressor module is available (ready to run) | ||
| ▄ | indicating that the compressor module is running | |||
| 
 | - (blinking) | indicating that the compressor module is not available (due to | ||
| 
 | minimum stop time or too many starts) | |||
| 
 | 
 | |||
| 
 | * (blinking) | indicating that the compressor module is shut down | ||
Note
When more than one message needs to be displayed (e.g. both warning and service), the messages will be displayed one after the other for 3 seconds.
Press key (F3) on the main screen to check which compressor module is running or stopped.