Instruction book
| Period | Running | Service | See | See | Operation | 
| 
 | hours | Plan | section | notes | 
 | 
| 
 | 
 | 
 | 
 | below | 
 | 
| 
 | 
 | 
 | 
 | table | 
 | 
| Daily | 3.4 | Drain condensate | |||
| " | On SF  | ||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
| Monthly | 250 | 5.1 | 1 | Inspect air filter | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 500 | Check pressure drop over Atlas Copco filters | ||||
| 
 | 
 | 
 | 
 | 
 | (optional) | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 5.4 | Operate safety valve | ||||
| " | Clean compressor | ||||
| " | On SF  | ||||
| 
 | 
 | 
 | 
 | 
 | surface of the condenser | 
| " | On SF  | ||||
| 
 | 
 | 
 | 
 | 
 | internally | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
| Yearly | 5.4 | Test safety valve | |||
| " | Have electrical  | ||||
| 
 | 
 | 
 | 
 | 
 | tested | 
| " | 2500 | I | 5.2 | Check tension/condition of  | |
| " | 5000 | A | 5.1 | Replace air filter | |
| " | 5000 | A | 2 | Have ball valve mechanism of condensate trap | |
| 
 | 
 | 
 | 
 | 
 | inspected | 
| " | 5000 | A | 5.2 | Replace  | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 5000 | B | 2 | Have orbiting scroll bearing greased | ||
| " | 10000 | B | 2 | Clean compressor element fan and duct. Clean | |
| 
 | 
 | 
 | 
 | 
 | compressor element fins, have seals replaced | 
| " | 10000 | B | 2 | Have pin crank bearings greased | 
Notes:
1.Check more frequently if operating in a dusty atmosphere. Check for cleanness and damage. Replace a dirty or damaged filter by a new one.
2.Consult Atlas Copco.
| 2920 1521 00 | 31 |