Atlas Air Compressor manual 12 SF6-15 Multi 8 bar 50 Hz, 13 SF6-15 Multi 10 bar 50 Hz

Page 39

Instruction book

7.12 SF6-15 Multi 8 bar 50 Hz 1)

Compressor type

 

SF6

SF8

SF11

SF15

 

 

8 bar

8 bar

8 bar

8 bar

Maximum working pressure for SF Pack

bar(e)

8

8

8

8

Maximum working pressure for SF Full-Feature

bar(e)

7.75

7.75

7.75

7.75

Nominal working pressure

bar(e)

7

7

7

7

Air temperature at outlet valve for SF Pack, approx.

°C

26

28

30

32

Air temperature at outlet valve for SF Full-Feature, approx.

°C

23

25

25

25

Motor shaft speed

r/min

2885

2885

2885

2885

Shaft input

kW

5.6

6.9

10.4

13.8

Sound pressure level

dB(A)

61

62

60

63

For SF Full-Feature also:

 

 

 

 

 

Refrigerant type

 

R134a

R134a

R134a

R134a

Pressure dewpoint, approx 2)

°C

3

3

3

3

7.13 SF6-15 Multi 10 bar 50 Hz 1)

Compressor type

 

SF6

SF8

SF11

SF15

 

 

10 bar

10 bar

10 bar

10 bar

Maximum working pressure for SF Pack

bar(e)

10

10

10

10

Maximum working pressure for SF Full-Feature

bar(e)

9.75

9.75

9.75

9.75

Nominal working pressure for SF Pack

bar(e)

10

10

10

10

Nominal working pressure for SF Full-Feature

bar(e)

9.75

9.75

9.75

9.75

Air temperature at outlet valve for SF Pack, approx.

°C

26

28

30

32

Air temperature at outlet valve for SF Full-Feature, approx.

°C

25

25

25

25

Motor shaft speed

r/min

2885

2885

2885

2885

Shaft input

kW

5.9

7.5

11.3

15.0

Sound pressure level

dB(A)

61

62

60

63

For SF Full-Feature also:

 

 

 

 

 

Refrigerant type

 

R134a

R134a

R134a

R134a

Pressure dewpoint, approx. 2)

°C

3

3

3

3

7.14 SF6-15 Multi 100 psi 60 Hz 1)

Compressor type

 

SF6

SF8

SF11

SF15

 

 

100 psi

100 psi

100 psi

100 psi

Maximum working pressure for SF Pack

bar(e)

8

8

8

8

Maximum working pressure for SF Full-Feature

bar(e)

7.75

7.75

7.75

7.75

Nominal working pressure

bar(e)

7

7

7

7

Air temperature at outlet valve for SF Pack,

°C

26

28

29

30

approx.

 

 

 

 

 

Air temperature at outlet valve for SF Full-

°C

23

25

25

25

Feature, approx.

 

 

 

 

 

Motor shaft speed

r/min

3495

3495

3495

3495

Shaft input SF Pack

kW

5.7

7.1

10.7

14.2

Shaft input SF Full-Feature

kW

5.8

7.2

10.8

14.4

Sound pressure level

dB(A)

61

62

60

63

For SF Full-Feature also:

 

 

 

 

 

Refrigerant type

 

R134a

R134a

R134a

R134a

Pressure dewpoint, approx 2)

°C

3

3

3

3

2920 1521 00

39

Image 39
Contents No 1521 Registration code APC SF / 38 Instruction bookInstruction book Skid Tank-mounted Twin Service warning message exists General description Leading ParticularsSF4 Skid Control panel Air outlet valve SF4 Tank-mounted SF8FF Multi Details of a compressor module on SF Tank-mounted Cooling and condensate drain systems Fig Air flowProtecting the compressor Regulating system on SF Skid Tank-mounted TwinAutomatic restart after voltage failure Monitoring components subject to serviceRegulating system on SF Multi Controlling the compressorDesignation Function Control panel FigTabulator key 4-Fig Display keysOperating condition of a compressor module Scroll keys 3-Fig13 Menu flow, SF Multi Selecting a menu14 Electric cabinets, SF Multi Electric cabinet on SF MultiAir dryer on SF Full-Feature Fig Compressed air circuitRefrigerant circuit Dimension drawings Figs .1 up to Installation9820 4054 00/1 Dimension drawing, SF 6-8 Multi Dimension drawing, SF 11-15 Multi Instruction book Installation proposal Fig Instruction book Electrical connections GeneralConnections Skid Tank-mounted Twin SF Multi TSHH20 Pictographs PictographsOperating Instructions Initial start-upStarting Taking out of operation at end of compressor service life During operationStopping Service plans on SF Multi MaintenancePreventive maintenance schedule for the compressor Before carrying out any maintenance or repairYearly MonthlyCoolers Adjustments and Servicing ProceduresAir filter 1-Figs .7/1.8 Belt exchange/tensioning FigSafety valve TestingOperating Problem Solving Principal Data Electric cable size for SF1-8Electric cable size for SF 6-15 Multi Overload relays for SF6-15 Multi Overload relays for SF1-8Reference conditions Main fuses for SF1-8Main fuses for SF6-15 Multi Reference conditions/limitations11 SF2-4 145 psi 60 Hz SF1-4 8bar 50 HzSF2-4 10 bar 50 Hz 10 SF1-4 100 psi 60 Hz12 SF6-15 Multi 8 bar 50 Hz 13 SF6-15 Multi 10 bar 50 Hz14 SF6-15 Multi 100 psi 60 Hz SF11 SF15 145 psi 15 SF6-15 Multi 125 psi 60 Hz16 SF6-15 Multi 145 psi 60 Hz SF11 SF15 125 psiMenu-driven control programs Regulator Functions for SF MultiMain screen Function of control programs Program/Function DescriptionElement status screen, typical example Line Indicates RemarksProcedure Quick look at actual compressor statusCalling up other menus Status data menu No message existsShut-down message exists Shut-down reset Measured data menu Service warning message existsTest menu Counters menuModifying parameters Modify parameters menuModifying the pressure bands Checking protections for compressor modules Modifying protection settingsService plans Modifying service plansProgrammed service plan intervals Service plans Intervals Resulting service actions to be carried outService actions according to Programming Clock function Programming start/stop/pressure band commandsInstruction book To modify a command To activate/deactivate the timerInstruction book To delete commands Adding a command between two existing commandsDeleting a specific start/stop/pressure band command Configuration menuDeleting all commands Deleting all commands related to a specific dayService menu Service plans ABI Saved data menu Regulation settings Minimum Nominal Maximum Setting Programmable settingsConversion List of SI Units Into US/BRITISH Units Service settings Minimum Nominal Maximum SettingComponents subject to 97/23/EC Pressure Equipment Directive Part number Description PED ClassOverall Rating Instruction book Instruction book Wnership Data Safety Preca Utions