Atlas Air Compressor manual Modifying the pressure bands

Page 50

Instruction book

8.8.1 Modifying the pressure bands

If desired, the operator can program two pressure bands (band 1 and band 2) with different pressure settings. The settings for band 1 are indicated as "Pressure Band 1 High" and "Pressure Band 1 Low", the settings for band 2 are indicated as " Pressure Band 2 High " and " Pressure Band 2 Low ".

Example:

 

 

For pressure band 1:

 

- Pressure Band 1 Low:

6.8 bar

- Pressure Band 1

High:

7.8 bar

For pressure band 2:

 

- Pressure Band 2

Low:

5.5 bar

- Pressure Band 2

High:

6.5 bar

Procedure

1. Consult the section above to select the parameter Pressure Band 1 High:

Pressure Band 1 High

 

7.8 bar

Pressure Band 1

Low

 

6.8 bar

 

Pressure Band 2

High

 

6.5 bar

Menu

 

Modify

 

 

F1

 

F2

F3

 

Fig. 8.11 Modify parameters menu

2.The screen shows that the current setting of Pressure Band 1 High is 7.8 bar(e). To modify this setting, press the key "Modify" (F2):

Pressure Band 1 High

 

7.8 bar

Program

Limits

Cancel

F1

F2

F3

Fig. 8.12 Modify parameters menu

3.The key "Limits" (F2) can be used to find the limitations for the parameter. Use the ↓ or ↑ arrow key to change the value.

4.Press the key "Program" (F1) to program the new setting or the key "Cancel" (F3) to cancel the modification operation.

5.The procedure to modify the Pressure Band 1 Low is similar to the description above.

6.If required, repeat the procedure for the Pressure Band 2 High and Pressure Band 2 Low (pressure band 2).

2920 1521 00

50

Image 50
Contents Instruction book No 1521 Registration code APC SF / 38Instruction book Skid Tank-mounted Twin Service warning message exists Leading Particulars General descriptionSF4 Skid Control panel Air outlet valve SF4 Tank-mounted SF8FF Multi Details of a compressor module on SF Tank-mounted Air flow Cooling and condensate drain systems FigRegulating system on SF Skid Tank-mounted Twin Protecting the compressorControlling the compressor Monitoring components subject to serviceRegulating system on SF Multi Automatic restart after voltage failureControl panel Fig Designation FunctionScroll keys 3-Fig Display keysOperating condition of a compressor module Tabulator key 4-FigSelecting a menu 13 Menu flow, SF MultiElectric cabinet on SF Multi 14 Electric cabinets, SF MultiRefrigerant circuit Air dryer on SF Full-Feature FigCompressed air circuit Installation Dimension drawings Figs .1 up to9820 4054 00/1 Dimension drawing, SF 6-8 Multi Dimension drawing, SF 11-15 Multi Instruction book Installation proposal Fig Instruction book Connections Skid Tank-mounted Twin Electrical connectionsGeneral SF Multi TSHH20 Pictographs PictographsStarting Operating InstructionsInitial start-up Stopping Taking out of operation at end of compressor service lifeDuring operation Before carrying out any maintenance or repair MaintenancePreventive maintenance schedule for the compressor Service plans on SF MultiMonthly YearlyBelt exchange/tensioning Fig Adjustments and Servicing ProceduresAir filter 1-Figs .7/1.8 CoolersOperating Safety valveTesting Problem Solving Electric cable size for SF 6-15 Multi Principal DataElectric cable size for SF1-8 Overload relays for SF1-8 Overload relays for SF6-15 MultiReference conditions/limitations Main fuses for SF1-8Main fuses for SF6-15 Multi Reference conditions10 SF1-4 100 psi 60 Hz SF1-4 8bar 50 HzSF2-4 10 bar 50 Hz 11 SF2-4 145 psi 60 Hz14 SF6-15 Multi 100 psi 60 Hz 12 SF6-15 Multi 8 bar 50 Hz13 SF6-15 Multi 10 bar 50 Hz SF11 SF15 125 psi 15 SF6-15 Multi 125 psi 60 Hz16 SF6-15 Multi 145 psi 60 Hz SF11 SF15 145 psiRegulator Functions for SF Multi Menu-driven control programsFunction of control programs Program/Function Description Main screenLine Indicates Remarks Element status screen, typical exampleCalling up other menus ProcedureQuick look at actual compressor status Shut-down message exists Status data menuNo message exists Shut-down reset Service warning message exists Measured data menuCounters menu Test menuModify parameters menu Modifying parametersModifying the pressure bands Modifying protection settings Checking protections for compressor modulesModifying service plans Service plansService actions according to Programmed service plan intervals Service plans IntervalsResulting service actions to be carried out Programming start/stop/pressure band commands Programming Clock functionInstruction book To activate/deactivate the timer To modify a commandInstruction book Adding a command between two existing commands To delete commandsDeleting all commands related to a specific day Configuration menuDeleting all commands Deleting a specific start/stop/pressure band commandService menu Service plans ABI Saved data menu Programmable settings Regulation settings Minimum Nominal Maximum SettingService settings Minimum Nominal Maximum Setting Conversion List of SI Units Into US/BRITISH UnitsOverall Rating Components subject to 97/23/EC Pressure Equipment DirectivePart number Description PED Class Instruction book Instruction book Wnership Data Safety Preca Utions