6 PROBLEM SOLVING
Before carrying out any maintenance or repair:
1.Stop the compressor, switch off the voltage and open the isolating switch.
2.Close the air outlet valve
1 | Compressor does not start |
a | Loose connection |
a | Have electrical connections checked |
b | Receiver pressure too high |
b | Compressor will start when the net pressure drops to the minimum pressure |
2 | Safety valve blows |
a | Safety valve opens too soon |
a | Replace valve |
|
|
3 | Compressor capacity or pressure below normal |
a | Air consumption exceeds capacity of compressor |
a | Check equipment connected |
b | Choked air filter |
b | Remove and check filter. Replace if necessary |
c | Safety valve leaking |
c | Replace valve |
d | Drive belt(s) slipping |
d | Check condition of belt(s). Correct or replace as required |
|
|
4 | Compressor module overheating / compressor shut down by its air temperature switch |
a | Insufficient compressor cooling |
a | Improve ventilation of compressor room. |
b | Cooling fan out of order |
b | Check and correct |
|
|
| On SF |
|
|
5 | Pressure dewpoint too high |
a | Shortage of refrigerant |
a | Have circuit repaired or recharged |
b | Refrigerant compressor does not run |
b | See 7 |
c | Condenser pressure is too high |
c | See 6 |
|
|
6 | Condenser pressure too high or too low |
a | Fan control switch out of order |
a | Have switch replaced |
b | Condenser fan motor out of order |
b | Have fan motor inspected |
c | Ambient temperature too high |
c | Improve ventilation. If necessary, draw the cooling air from a cooler room |
d | Condenser externally clogged |
d | Clean condenser |
|
|
7 | Motor of refrigerant compressor stops or does not start |
a | Thermal protection of the motor has tripped |
a | Compressor will restart when the motor windings have cooled down |
2920 1521 00 | 34 |