Atlas Air Compressor manual Overload relays for SF1-8, Overload relays for SF6-15 Multi

Page 36

Instruction book

7.3 Overload relays for SF1-8

Frequency

Voltage

SF1

SF2

SF2

SF4

SF6

SF8

 

 

single-

single-

3-phase

3-phase

3-phase

3-phase

 

 

phase

phase

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IEC

 

 

 

 

 

 

 

 

50 Hz

230 V

12 A

14.5 A

8.3 A

14 A

8.3 and 14 A

2x

14 A

50 Hz

400 V

 

 

4.8 A

8.2 A

4.8 and 8.2 A

2x

8.2 A

60 Hz

380 V

 

 

5.1 A

8.5 A

5.1 and 8.5 A

2x

8.5 A

50 Hz

500 V

 

 

3.8 A

6.5 A

3.8 and 6.5 A

2x

6.5 A

 

 

 

 

 

 

 

 

 

CSA/UL

 

 

 

 

 

 

 

 

60 Hz

230 V

10.2 A

14.7 A

9.2 A

15.3 A

9.2 and 15.3 A

2x

15.3 A

60 Hz

440/460 V

 

 

4.6 A

7.7 A

4.6 and 7.7 A

2x

7.7 A

Note: SF6 Twin have compressor modules of a different size, the first value is valid for the smaller SF2 module and the second one is valid for the bigger SF4 module

7.4 Overload relays for SF6-15 Multi

Frequency

Voltage

SF6

SF8

SF11

SF15

 

 

3-phase

3-phase

3-phase

3-phase

 

 

 

 

 

 

 

 

 

IEC

 

 

 

 

 

 

 

 

50 Hz

230 V

8 and 14 A

2x

14 A

3x

14 A

4x

14 A

50 Hz

400 V

4.8 and 8 A

2x

8 A

3x

8 A

4x

8 A

60 Hz

380 V

5 and 8.5 A

2x

8.5 A

3x

8.5 A

4x

8.5 A

50 Hz

500 V

3.6 and 6.4 A

2x

6.4 A

3x

6.4 A

4x

6.4 A

 

 

 

 

 

 

 

 

 

CSA/UL

 

 

 

 

 

 

 

 

60 Hz

230 V

9 and 15 A

2x

15 A

3x

15 A

4x

15 A

60 Hz

440/460 V

4.5 and 7.5 A

2x

7.5 A

3x

7.5 A

4x

7.5 A

60 Hz

575 V

3.5 and 5.5 A

2x

5.5 A

3x

5.5 A

4x

5.5 A

Note: SF6 have compressor modules of a different size, the first value is valid for the smaller SF2 module (lower element) and the second one is valid for the bigger SF4 module (higher element)

2920 1521 00

36

Image 36
Contents Instruction book No 1521 Registration code APC SF / 38Instruction book Skid Tank-mounted Twin Service warning message exists Leading Particulars General descriptionSF4 Skid Control panel Air outlet valve SF4 Tank-mounted SF8FF Multi Details of a compressor module on SF Tank-mounted Air flow Cooling and condensate drain systems FigRegulating system on SF Skid Tank-mounted Twin Protecting the compressorMonitoring components subject to service Regulating system on SF MultiControlling the compressor Automatic restart after voltage failureControl panel Fig Designation FunctionDisplay keys Operating condition of a compressor moduleScroll keys 3-Fig Tabulator key 4-FigSelecting a menu 13 Menu flow, SF MultiElectric cabinet on SF Multi 14 Electric cabinets, SF MultiAir dryer on SF Full-Feature Fig Compressed air circuitRefrigerant circuit Installation Dimension drawings Figs .1 up to9820 4054 00/1 Dimension drawing, SF 6-8 Multi Dimension drawing, SF 11-15 Multi Instruction book Installation proposal Fig Instruction book Electrical connections GeneralConnections Skid Tank-mounted Twin SF Multi TSHH20 Pictographs PictographsOperating Instructions Initial start-upStarting Taking out of operation at end of compressor service life During operationStopping Maintenance Preventive maintenance schedule for the compressorBefore carrying out any maintenance or repair Service plans on SF MultiMonthly YearlyAdjustments and Servicing Procedures Air filter 1-Figs .7/1.8Belt exchange/tensioning Fig CoolersSafety valve TestingOperating Problem Solving Principal Data Electric cable size for SF1-8Electric cable size for SF 6-15 Multi Overload relays for SF1-8 Overload relays for SF6-15 MultiMain fuses for SF1-8 Main fuses for SF6-15 MultiReference conditions/limitations Reference conditionsSF1-4 8bar 50 Hz SF2-4 10 bar 50 Hz10 SF1-4 100 psi 60 Hz 11 SF2-4 145 psi 60 Hz12 SF6-15 Multi 8 bar 50 Hz 13 SF6-15 Multi 10 bar 50 Hz14 SF6-15 Multi 100 psi 60 Hz 15 SF6-15 Multi 125 psi 60 Hz 16 SF6-15 Multi 145 psi 60 HzSF11 SF15 125 psi SF11 SF15 145 psiRegulator Functions for SF Multi Menu-driven control programsFunction of control programs Program/Function Description Main screenLine Indicates Remarks Element status screen, typical exampleProcedure Quick look at actual compressor statusCalling up other menus Status data menu No message existsShut-down message exists Shut-down reset Service warning message exists Measured data menuCounters menu Test menuModify parameters menu Modifying parametersModifying the pressure bands Modifying protection settings Checking protections for compressor modulesModifying service plans Service plansProgrammed service plan intervals Service plans Intervals Resulting service actions to be carried outService actions according to Programming start/stop/pressure band commands Programming Clock functionInstruction book To activate/deactivate the timer To modify a commandInstruction book Adding a command between two existing commands To delete commandsConfiguration menu Deleting all commandsDeleting all commands related to a specific day Deleting a specific start/stop/pressure band commandService menu Service plans ABI Saved data menu Programmable settings Regulation settings Minimum Nominal Maximum SettingService settings Minimum Nominal Maximum Setting Conversion List of SI Units Into US/BRITISH UnitsComponents subject to 97/23/EC Pressure Equipment Directive Part number Description PED ClassOverall Rating Instruction book Instruction book Wnership Data Safety Preca Utions