Instruction book
7.3 Overload relays for SF1-8
Frequency | Voltage | SF1 | SF2 | SF2 | SF4 | SF6 | SF8 | |
|
| single- | single- | |||||
|
| phase | phase |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
IEC |
|
|
|
|
|
|
|
|
50 Hz | 230 V | 12 A | 14.5 A | 8.3 A | 14 A | 8.3 and 14 A | 2x | 14 A |
50 Hz | 400 V |
|
| 4.8 A | 8.2 A | 4.8 and 8.2 A | 2x | 8.2 A |
60 Hz | 380 V |
|
| 5.1 A | 8.5 A | 5.1 and 8.5 A | 2x | 8.5 A |
50 Hz | 500 V |
|
| 3.8 A | 6.5 A | 3.8 and 6.5 A | 2x | 6.5 A |
|
|
|
|
|
|
|
|
|
CSA/UL |
|
|
|
|
|
|
|
|
60 Hz | 230 V | 10.2 A | 14.7 A | 9.2 A | 15.3 A | 9.2 and 15.3 A | 2x | 15.3 A |
60 Hz | 440/460 V |
|
| 4.6 A | 7.7 A | 4.6 and 7.7 A | 2x | 7.7 A |
Note: SF6 Twin have compressor modules of a different size, the first value is valid for the smaller SF2 module and the second one is valid for the bigger SF4 module
7.4 Overload relays for SF6-15 Multi
Frequency | Voltage | SF6 | SF8 | SF11 | SF15 | |||
|
| |||||||
|
|
|
|
|
|
|
|
|
IEC |
|
|
|
|
|
|
|
|
50 Hz | 230 V | 8 and 14 A | 2x | 14 A | 3x | 14 A | 4x | 14 A |
50 Hz | 400 V | 4.8 and 8 A | 2x | 8 A | 3x | 8 A | 4x | 8 A |
60 Hz | 380 V | 5 and 8.5 A | 2x | 8.5 A | 3x | 8.5 A | 4x | 8.5 A |
50 Hz | 500 V | 3.6 and 6.4 A | 2x | 6.4 A | 3x | 6.4 A | 4x | 6.4 A |
|
|
|
|
|
|
|
|
|
CSA/UL |
|
|
|
|
|
|
|
|
60 Hz | 230 V | 9 and 15 A | 2x | 15 A | 3x | 15 A | 4x | 15 A |
60 Hz | 440/460 V | 4.5 and 7.5 A | 2x | 7.5 A | 3x | 7.5 A | 4x | 7.5 A |
60 Hz | 575 V | 3.5 and 5.5 A | 2x | 5.5 A | 3x | 5.5 A | 4x | 5.5 A |
Note: SF6 have compressor modules of a different size, the first value is valid for the smaller SF2 module (lower element) and the second one is valid for the bigger SF4 module (higher element)
2920 1521 00 | 36 |